1. Introduction
The LEIRONG BP2000 Peristaltic Pump is a high-flow dosing pump designed for precise liquid transfer in various applications. Featuring a robust DC motor, this pump ensures that the liquid only comes into contact with the pump tube, maintaining hygiene and preventing contamination of the pump mechanism. Its design incorporates features like spring compensation for extended tube life and an adjustable two-speed buckle for optimizing tightness based on liquid characteristics.

Video 1: Product demonstration of the LEIRONG BP2000 Peristaltic Pump, highlighting its features and operation.
2. Safety Information
- Ensure the pump is connected to the correct voltage (12V or 24V DC) as specified for your model. Incorrect voltage can damage the pump.
- Always disconnect power before performing any maintenance, cleaning, or pump tube replacement.
- Use appropriate pump tube materials for the liquids being transferred to prevent chemical degradation, ensure safe operation, and maintain flow accuracy. Refer to the 'Pump Tube Material Selection' table.
- Do not operate the pump if any parts are damaged, missing, or if the pump tube is visibly worn or compromised.
- Keep the pump away from excessive heat, moisture, and corrosive environments unless specifically designed for such conditions.
3. Setup and Installation
The BP2000 pump offers flexible installation options. Ensure the mounting surface is stable and secure to prevent vibration and ensure consistent performance.
3.1 Component Overview

3.2 Mounting the Pump
The pump can be installed in two main configurations, Type A and Type B, depending on your application's mounting requirements:

- Type A Installation: Mount the pump directly to a panel or surface using appropriate screws.
- Type B Installation: Utilize the included mounting bracket to secure the pump to a surface, providing an alternative mounting orientation.
The pump tube can be oriented as needed for your specific application by adjusting its position within the pump head.
3.3 Connecting Tubing
Connect the inlet and outlet tubing to the pump's ports. Ensure all connections are secure and leak-free. The pump supports bidirectional conveying, allowing liquid flow direction to be reversed by changing the motor's rotation direction (if applicable to your control system).

3.4 Power Connection
Connect the DC motor to a 12V or 24V DC power supply, matching the voltage specification of your particular pump model. Always observe correct polarity to prevent damage to the motor.
4. Operating Instructions
The LEIRONG BP2000 is designed for simple and reliable operation. Follow these steps for effective use:
4.1 Basic Operation
- Ensure all tubing connections are secure and the pump is properly mounted.
- Verify the pump tube is correctly installed within the pump head and the two-speed buckle is adjusted for appropriate tightness.
- Apply power to the DC motor. The pump will begin to transfer liquid.
- Monitor the flow to ensure proper operation and check for any leaks or anomalies.
4.2 Flow Rate Control
The flow rate of the pump is primarily determined by the type of pump tube used and the applied voltage. For specific flow rates, refer to the 'Flow Rate Table' in the Specifications section.
4.3 Two-speed Buckle Adjustment
The pump features a two-speed buckle mechanism that allows for adjustable tightness of the pump tube. This adjustment can be used to optimize performance based on the viscosity of the liquid and the desired flow stability.

5. Maintenance
Regular maintenance, particularly pump tube replacement, is essential for ensuring optimal performance, accuracy, and longevity of your peristaltic pump.
5.1 Pump Tube Replacement
The pump tube is a consumable component and will wear out over time, requiring periodic replacement. The pump incorporates a spring compensation mechanism designed to extend the life of the tube, but replacement will eventually be necessary.

Follow these steps to safely and effectively replace the pump tube:

- Step 1: Unscrew the screw holding the pump head cover.
- Step 2: Open the lever and bridge block to release tension on the tube.
- Step 3: Open the clips on both sides and carefully remove the old pump tube.
- Step 4: Insert the new pump tube, ensuring it is properly seated within the pump head. Close the clips, bridge block, lever, and secure the screw.
5.2 Cleaning
Due to the peristaltic design, the liquid being pumped only contacts the pump tube. Therefore, cleaning of the pump mechanism itself is generally not required. If the exterior of the pump needs cleaning, wipe it with a soft, damp cloth. Do not immerse the pump in any liquid.

6. Troubleshooting
- No liquid flow:
- Check power connection and ensure the correct voltage (12V or 24V) is applied.
- Ensure the pump tube is correctly installed, not kinked, or blocked by debris.
- Verify the two-speed buckle is properly adjusted to compress the tube sufficiently.
- Inspect the pump tube for excessive wear or damage; replace if necessary.
- Inconsistent flow rate:
- Check for air bubbles in the tubing system, which can disrupt flow.
- Ensure the pump tube is not worn out, stretched, or hardened, which can affect compression.
- Adjust the two-speed buckle for optimal tightness to ensure consistent tube compression.
- Verify the liquid viscosity is within the pump's operating range and consistent.
- Pump making unusual noise:
- Check for any foreign objects or obstructions in the pump head.
- Ensure the pump is securely mounted and not vibrating against other surfaces.
- Inspect the pump tube for proper installation and ensure it is not rubbing excessively.
- If the noise persists, the motor or gears may require inspection by a qualified technician.
7. Specifications
| Feature | Specification |
|---|---|
| Brand Name | LEIRONG |
| Model Number | BP2000 |
| Power Source | Electric (DC Motor) |
| Voltage | 12V / 24V |
| Application | Metering |
| Structure | Peristaltic Pump, Reduction gear |
| Pressure | Low Pressure |
| Pump Housing Material | PA66+PC |
| Rollers Quantity | 3 |
| Flow Rate (max) | Up to 2200 ml/min (depending on tube type and voltage) |
| Pump Lifetime | 1000H |
| Certification | CE, RoHS, ISO9001 |
| Origin | China Mainland |
| Package Dimensions | 24cm (L) x 20cm (W) x 17cm (H) |
| Package Weight | 0.9 kg |
7.1 Flow Rate Table

| Tube Species | ID x OD (mm) | Flow Rate (ml/min) | |
|---|---|---|---|
| 12V/2A | 24V/1A | ||
| S64H | 6.4 x 11.2 | 1600 | 1600 |
| S79H | 7.9 x 12.7 | 2200 | 2200 |
| N64H | 6.4 x 11.2 | 1600 | 1600 |
| N79H | 7.9 x 12.7 | 2100 | 2100 |
*Operating conditions: ambient temperature 0-50°C, relative humidity less than 80%.
7.2 Pump Tube Material Selection

| Type | Material | Characteristics | Temp Range | Life (Hrs) |
|---|---|---|---|---|
| Cost Effective | Silicone Tube | Low cost, poor chemical resistance | -50°C~200°C | ~200 |
| Medical Grade | Pharmed BPT Tube | Chem Resist (Acids/Alkalis/Oxides), Opaque (UV Resist), High/Low Temp Resist, Wear/Pressure Resist, Good Elasticity | -51°C~135°C | ~1000 |
| Food Grade | Norprene A-60-F Tube | Almost resists common disinfectants/cleaners, Ozone/UV Resist, Reusable (heating/pressurization), Good flex fatigue Resist | -59°C~135°C | ~1000 |
| Industrial Use | Norprene A-60-G Tube | High Temp Resist, Light/Ozone Resist, Suitable for soap/disinfectant/ink transfer | -60°C~135°C | ~1000 |
| Corr. High-Purity | Norprene Chemical Tube | Suitable for extreme chemical environments, excellent chem resist, PTFE lining, anti-fluid adsorption/adhesion, flexible outer layer, long pump tube life | -60°C~74°C | ~500 |
| Strong Acid/Alkali | Viton tube | High Temp/Strong Acid-Alkali Resist, Long Service Life, Ultra-pure, Non-toxic, Excellent Chem Inertness | -32°C~204°C | ~500 |
7.3 Product Dimensions

| Dimension | Type A | Type B |
|---|---|---|
| Width | 94.6 mm | 95 mm |
| Height | 94.1 mm | 101.3 mm |
| Length | 153 mm | 153.4 mm |
8. User Tips
- Motor Compatibility: The BP2000 comes with a DC motor. If your application requires extremely precise flow control or integration with specific motion control systems, consider if a stepper motor (e.g., NEMA 42) might be a more suitable alternative. LEIRONG offers customization options for speed control plates and Hall encoders, which can enhance control capabilities.
- Chemical Compatibility: When dispensing various liquids such as detergents, degreasers, or chlorine, it is crucial to select the correct pump tube material. Always refer to the "Pump Tube Material Selection" table in the Specifications section to ensure the chosen tube is chemically resistant to your specific fluid. This prevents tube degradation, ensures accurate dispensing, and prolongs the life of the tube.
9. Warranty and Support
LEIRONG products are manufactured under strict quality control standards and are certified with CE, RoHS, and ISO9001, ensuring reliability and performance. For any technical assistance, troubleshooting, or support inquiries, please contact LEIRONG Official Store customer service. Our professional team is available to assist you with product-related questions and concerns.