LEIRONG BP2000

Contents

LEIRONG BP2000 Peristaltic Pump User Manual

High Flow Dosing Pump with DC Motor

1. Introduction

The LEIRONG BP2000 Peristaltic Pump is a high-flow dosing pump designed for precise liquid transfer in various applications. Featuring a robust DC motor, this pump ensures that the liquid only comes into contact with the pump tube, maintaining hygiene and preventing contamination of the pump mechanism. Its design incorporates features like spring compensation for extended tube life and an adjustable two-speed buckle for optimizing tightness based on liquid characteristics.

LEIRONG BP2000 Peristaltic Pump
Figure 1: LEIRONG BP2000 Peristaltic Pump, showing its compact design and transparent pump head.

Video 1: Product demonstration of the LEIRONG BP2000 Peristaltic Pump, highlighting its features and operation.

2. Safety Information

  • Ensure the pump is connected to the correct voltage (12V or 24V DC) as specified for your model. Incorrect voltage can damage the pump.
  • Always disconnect power before performing any maintenance, cleaning, or pump tube replacement.
  • Use appropriate pump tube materials for the liquids being transferred to prevent chemical degradation, ensure safe operation, and maintain flow accuracy. Refer to the 'Pump Tube Material Selection' table.
  • Do not operate the pump if any parts are damaged, missing, or if the pump tube is visibly worn or compromised.
  • Keep the pump away from excessive heat, moisture, and corrosive environments unless specifically designed for such conditions.

3. Setup and Installation

The BP2000 pump offers flexible installation options. Ensure the mounting surface is stable and secure to prevent vibration and ensure consistent performance.

3.1 Component Overview

Peristaltic pump with cover removed
Figure 2: Pump with transparent cover removed, showing the internal pump head and tube path.

3.2 Mounting the Pump

The pump can be installed in two main configurations, Type A and Type B, depending on your application's mounting requirements:

Installation diagrams for Type A and Type B pump configurations
Figure 3: Type A and Type B Installation Diagrams. The pump tube can be switched to face the schematic for flexible routing.
  • Type A Installation: Mount the pump directly to a panel or surface using appropriate screws.
  • Type B Installation: Utilize the included mounting bracket to secure the pump to a surface, providing an alternative mounting orientation.

The pump tube can be oriented as needed for your specific application by adjusting its position within the pump head.

3.3 Connecting Tubing

Connect the inlet and outlet tubing to the pump's ports. Ensure all connections are secure and leak-free. The pump supports bidirectional conveying, allowing liquid flow direction to be reversed by changing the motor's rotation direction (if applicable to your control system).

Peristaltic pump demonstrating bidirectional conveying
Figure 4: Bidirectional Conveying - The design ensures liquid only contacts the pump tube, maintaining cleanliness and preventing contamination of the pump mechanism.

3.4 Power Connection

Connect the DC motor to a 12V or 24V DC power supply, matching the voltage specification of your particular pump model. Always observe correct polarity to prevent damage to the motor.

4. Operating Instructions

The LEIRONG BP2000 is designed for simple and reliable operation. Follow these steps for effective use:

4.1 Basic Operation

  1. Ensure all tubing connections are secure and the pump is properly mounted.
  2. Verify the pump tube is correctly installed within the pump head and the two-speed buckle is adjusted for appropriate tightness.
  3. Apply power to the DC motor. The pump will begin to transfer liquid.
  4. Monitor the flow to ensure proper operation and check for any leaks or anomalies.

4.2 Flow Rate Control

The flow rate of the pump is primarily determined by the type of pump tube used and the applied voltage. For specific flow rates, refer to the 'Flow Rate Table' in the Specifications section.

4.3 Two-speed Buckle Adjustment

The pump features a two-speed buckle mechanism that allows for adjustable tightness of the pump tube. This adjustment can be used to optimize performance based on the viscosity of the liquid and the desired flow stability.

Detail of the two-speed buckle on the peristaltic pump
Figure 5: Two-speed Buckle for adjustable tightness, allowing fine-tuning of pump tube compression.

5. Maintenance

Regular maintenance, particularly pump tube replacement, is essential for ensuring optimal performance, accuracy, and longevity of your peristaltic pump.

5.1 Pump Tube Replacement

The pump tube is a consumable component and will wear out over time, requiring periodic replacement. The pump incorporates a spring compensation mechanism designed to extend the life of the tube, but replacement will eventually be necessary.

Detail of spring compensation mechanism in the pump
Figure 6: Spring compensation mechanism, designed to prevent tube return and extend the operational lifespan of the pump tube.

Follow these steps to safely and effectively replace the pump tube:

Four-step diagram for replacing the pump tube
Figure 7: Pump Tube Replacement Steps.
  1. Step 1: Unscrew the screw holding the pump head cover.
  2. Step 2: Open the lever and bridge block to release tension on the tube.
  3. Step 3: Open the clips on both sides and carefully remove the old pump tube.
  4. Step 4: Insert the new pump tube, ensuring it is properly seated within the pump head. Close the clips, bridge block, lever, and secure the screw.

5.2 Cleaning

Due to the peristaltic design, the liquid being pumped only contacts the pump tube. Therefore, cleaning of the pump mechanism itself is generally not required. If the exterior of the pump needs cleaning, wipe it with a soft, damp cloth. Do not immerse the pump in any liquid.

Peristaltic pump demonstrating clean and hygienic operation
Figure 8: Clean and Hygienic operation - liquid only contacts the pump tube, minimizing contamination risks.

6. Troubleshooting

No liquid flow:
  • Check power connection and ensure the correct voltage (12V or 24V) is applied.
  • Ensure the pump tube is correctly installed, not kinked, or blocked by debris.
  • Verify the two-speed buckle is properly adjusted to compress the tube sufficiently.
  • Inspect the pump tube for excessive wear or damage; replace if necessary.
Inconsistent flow rate:
  • Check for air bubbles in the tubing system, which can disrupt flow.
  • Ensure the pump tube is not worn out, stretched, or hardened, which can affect compression.
  • Adjust the two-speed buckle for optimal tightness to ensure consistent tube compression.
  • Verify the liquid viscosity is within the pump's operating range and consistent.
Pump making unusual noise:
  • Check for any foreign objects or obstructions in the pump head.
  • Ensure the pump is securely mounted and not vibrating against other surfaces.
  • Inspect the pump tube for proper installation and ensure it is not rubbing excessively.
  • If the noise persists, the motor or gears may require inspection by a qualified technician.

7. Specifications

FeatureSpecification
Brand NameLEIRONG
Model NumberBP2000
Power SourceElectric (DC Motor)
Voltage12V / 24V
ApplicationMetering
StructurePeristaltic Pump, Reduction gear
PressureLow Pressure
Pump Housing MaterialPA66+PC
Rollers Quantity3
Flow Rate (max)Up to 2200 ml/min (depending on tube type and voltage)
Pump Lifetime1000H
CertificationCE, RoHS, ISO9001
OriginChina Mainland
Package Dimensions24cm (L) x 20cm (W) x 17cm (H)
Package Weight0.9 kg

7.1 Flow Rate Table

Table showing flow rates for different tube species and voltages
Figure 9: Flow rate (ml/min) for various tube species at 12V and 24V.
Tube SpeciesID x OD (mm)Flow Rate (ml/min)
12V/2A24V/1A
S64H6.4 x 11.216001600
S79H7.9 x 12.722002200
N64H6.4 x 11.216001600
N79H7.9 x 12.721002100

*Operating conditions: ambient temperature 0-50°C, relative humidity less than 80%.

7.2 Pump Tube Material Selection

Table for pump tube material selection based on characteristics
Figure 10: Pump Tube Selection Guide, detailing material characteristics, temperature ranges, and estimated lifespan.
TypeMaterialCharacteristicsTemp RangeLife (Hrs)
Cost EffectiveSilicone TubeLow cost, poor chemical resistance-50°C~200°C~200
Medical GradePharmed BPT TubeChem Resist (Acids/Alkalis/Oxides), Opaque (UV Resist), High/Low Temp Resist, Wear/Pressure Resist, Good Elasticity-51°C~135°C~1000
Food GradeNorprene A-60-F TubeAlmost resists common disinfectants/cleaners, Ozone/UV Resist, Reusable (heating/pressurization), Good flex fatigue Resist-59°C~135°C~1000
Industrial UseNorprene A-60-G TubeHigh Temp Resist, Light/Ozone Resist, Suitable for soap/disinfectant/ink transfer-60°C~135°C~1000
Corr. High-PurityNorprene Chemical TubeSuitable for extreme chemical environments, excellent chem resist, PTFE lining, anti-fluid adsorption/adhesion, flexible outer layer, long pump tube life-60°C~74°C~500
Strong Acid/AlkaliViton tubeHigh Temp/Strong Acid-Alkali Resist, Long Service Life, Ultra-pure, Non-toxic, Excellent Chem Inertness-32°C~204°C~500

7.3 Product Dimensions

Diagram showing dimensions for Type A and Type B pump models
Figure 11: Product Size for Type A and Type B configurations, showing width, height, and length.
DimensionType AType B
Width94.6 mm95 mm
Height94.1 mm101.3 mm
Length153 mm153.4 mm

8. User Tips

  • Motor Compatibility: The BP2000 comes with a DC motor. If your application requires extremely precise flow control or integration with specific motion control systems, consider if a stepper motor (e.g., NEMA 42) might be a more suitable alternative. LEIRONG offers customization options for speed control plates and Hall encoders, which can enhance control capabilities.
  • Chemical Compatibility: When dispensing various liquids such as detergents, degreasers, or chlorine, it is crucial to select the correct pump tube material. Always refer to the "Pump Tube Material Selection" table in the Specifications section to ensure the chosen tube is chemically resistant to your specific fluid. This prevents tube degradation, ensures accurate dispensing, and prolongs the life of the tube.

9. Warranty and Support

LEIRONG products are manufactured under strict quality control standards and are certified with CE, RoHS, and ISO9001, ensuring reliability and performance. For any technical assistance, troubleshooting, or support inquiries, please contact LEIRONG Official Store customer service. Our professional team is available to assist you with product-related questions and concerns.

LEIRONG company information and certifications
Figure 12: LEIRONG Company Information and Certifications, highlighting quality standards and support.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.