LEIRONG BP300 Stepper motor

Contents

LEIRONG BP300 Stepper Motor Peristaltic Pump Instruction Manual

High Precision Peristaltic Pump for Water, Liquid Dosing, Gel, and Grease Transfer

1. Introduction

This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your LEIRONG BP300 Stepper Motor Peristaltic Pump. Please read this manual thoroughly before using the product to ensure optimal performance and longevity.

Video: Overview of the LEIRONG BP300 Stepper Motor Peristaltic Pump, demonstrating its features and operation.

2. Key Features

  • High Precision: Stepper motor ensures accurate and consistent flow rates.
  • Low Noise: Designed for quiet operation.
  • Easy Tube Replacement: Flip-top cover design and slider mechanism for quick and simple tube changes.
  • Spring Compensation: Protects the pump tube and provides a cushioning effect.
  • Durable Construction: Made from PA66+PC material for high strength and stable performance.
  • Versatile Application: Suitable for various liquids, gels, and greases.
  • Long Service Life: Stepper motor designed for 8000+ hours of operation.
  • Clean and Hygienic: Liquid only contacts the pump tube, preventing contamination.
Key features of the BP300 pump: Visual Work, Robust Power, Low Noise, Smooth operation.

Image: Visual representation of key features: Visual Work, Robust Power, Low Noise, Smooth operation.

3. Specifications

BP300 Stepper Motor Peristaltic Pump Specifications
ItemValue
Model NumberBP300 Stepper motor
Flow Range≤450ml/min
BrandLEIRONG
ApplicationLab Equipment, Aquarium Dosing, Environmental Instruments, Food Machinery, Medical Instruments, Online Monitoring, Smart Retail, Smart Agriculture
PressureHigh Pressure
Power SourceElectric
Motor TypeStepper motor
Control ModePLC/485
Voltage12V / 24V
Weight515g
Pump TubeSilicone tube / Norprene tube
Rollers quantity3
Noise≤60dB
Power (W)36W
MaterialPA66+PC
Lifetime10000H (Motor)
CertificationCE, RoHS, ISO9001
OriginChina Mainland

Flow Rate Parameters (Ambient Temperature 0-50°C, Relative Humidity <80%)

Tube SpeciesID×ODFlow rate (ml/min) @ 12/24V 1.2A
S32/N323.2X6.4230
S40/N404X7.2340
S48/N484.8X8450

Note: Flow rate data is for reference only, based on water test at room temperature (20°C) and atmospheric pressure. Deviations may occur depending on liquid properties, pressure, and pipeline lengths.

4. Structural Decomposition & Model Interpretation

The BP300 peristaltic pump features a robust design for reliable performance:

  • The spring compensation structure extends the life of the pump pipe and prevents negative pressure instability of the liquid return.
  • Stepper motor provides precise control, long life, and low noise.
  • High-quality raw materials ensure high strength and stable performance.
  • Supports stepper motor and DC motor brushless motor.
  • Pump tube direction can be changed at will.

Model Definition: BP300-S42UN32A (Example)

Diagram explaining the BP300 model definition, detailing stepper motor, pipe outlet mode, tube type, and installation mode.

Image: Model Definition Breakdown.

  • BP300: Base model.
  • S42: S42:42 Stepper motor.
  • U: Pipe outlet mode (U-type).
  • N32: Norprene tube, 3.2x6.4mm (IDxOD).
  • A: Installation mode A.

Other variations exist for pipe outlet mode (e.g., I-type), tube material (S for Silicone), and installation mode (B).

5. Setup and Installation

The BP300 pump offers flexible installation options. Ensure the pump is securely mounted before operation.

Installation Mode A

3D rendering of Type A installation diagram for the peristaltic pump.

Image: Type A Installation Diagram.

Refer to the diagram for dimensions and mounting points for Installation Mode A. This mode typically involves mounting the pump directly to a flat surface using screws.

Installation Mode B

3D rendering of Type B installation diagram for the peristaltic pump.

Image: Type B Installation Diagram.

Refer to the diagram for dimensions and mounting points for Installation Mode B. This mode may involve a bracket or different mounting orientation.

Vertical Installation Mode (Type B)

Schematic diagram showing switchable pump pipe orientation for vertical installation mode (Type B).

Image: Schematic diagram of pump pipe switchable orientation for vertical installation (Type B).

For vertical installations using Type B, the pump pipe orientation can be switched as shown in the schematic diagram to accommodate different flow directions.

Wiring Instructions

The BP300 stepper motor requires a compatible driver for operation. Ensure correct wiring to prevent damage.

Wiring diagram for the stepper motor, showing line sequence and connections (RED A+, BLU A-, B+ GRN, B- BLK).

Image: Stepper Motor Wiring Diagram.

Line Sequence:

  • User side connector (XH-4Y): Red, Blue, Green, Black
  • Motor side connector (PH-6Y): 1 black, 3 green, 4 red, 6 blue

Motor Connections:

  • RED A+
  • BLU A-
  • B+ GRN
  • B- BLK

Stepper Motor Control Precautions:

  • The initial torque required when the stepper motor is started is high. The required torque is 2-3 times the constant speed torque of the hose and the roller. When driven by a high-frequency stepper motor, acceleration and deceleration processing on the control is necessary.
  • If the pump load is high and the initial rotation is blocked, try to apply a current 10%-20% higher than the rated current of the motor to achieve a constant speed. Adjust the appropriate current carefully to avoid motor damage.

6. Operation

Once installed and wired correctly, the BP300 peristaltic pump is ready for operation. The pump operates by compressing and releasing the pump tube, moving fluid through it. The flow rate is controlled by the speed of the stepper motor.

Ensure the pump tube is correctly installed and secured before starting operation. Monitor the flow to ensure it meets your application requirements.

Diagram illustrating the clean and hygienic liquid path, showing liquid only contacts the pump tube.

Image: Clean and Hygienic Liquid Path. Liquid only contacts the pump tube.

7. Pump Tube Selection

Choosing the correct pump tube material is crucial for performance and longevity. The BP300 pump supports both Silicone and Norprene tubes.

Table detailing pump tube selection based on material, characteristics, temperature range, and lifespan.

Image: Pump Tube Selection Guide.

Code/MaterialFeaturesTube Life
N (Norprene tube)FDA certification, suitable for food and dairy applications, heat resistance, ozone resistance, acid and alkali resistance, anti-aging, anti-oxidation. Working temperature range: -59℃ ~ 135℃.≥1000h
S (Silicone tube)Low cost, weak acid and alkali resistance, corrosion resistance to chemicals compared to Norprene pump pipe. Working temperature range: -50℃ ~ 200℃.~200 Hrs

Note: The service life of the pump tube may vary depending on operating conditions, pipeline pressure, and liquid corrosiveness. Slower rotational speeds generally lead to longer tube life.

8. Maintenance: Pump Tube Replacement

Regular inspection and replacement of the pump tube are essential for maintaining pump performance and preventing leaks.

Four-step visual guide for replacing the pump tube: pinch cover, open lever, remove old tube, replace with new tube.

Image: Visual guide for pump tube replacement.

  1. Pinch the bottom sides of the pump cover to open the cover.
  2. Open the lever and bridge block.
  3. Remove the old pump tube.
  4. Replace with the new pump pipe, ensuring it is seated correctly. Close the lever and pump cover.

9. Troubleshooting

This section provides solutions to common issues you might encounter with your BP300 peristaltic pump.

ProblemPossible CauseSolution
No flow or inconsistent flow
  • Pump tube worn out or damaged.
  • Incorrect tube size or material.
  • Blockage in tubing.
  • Motor not receiving power or incorrect wiring.
  • Driver issue.
  • Replace pump tube (see Maintenance section).
  • Ensure correct tube type and dimensions.
  • Check and clear any blockages in the fluid path.
  • Verify power supply and wiring connections (see Wiring Instructions).
  • Check stepper motor driver functionality.
Excessive noise during operation
  • Worn pump tube.
  • Improper installation/mounting.
  • Motor issues.
  • Replace pump tube.
  • Ensure pump is securely mounted and level.
  • Inspect motor for any visible damage or loose parts.
Motor not turning
  • No power.
  • Incorrect wiring.
  • Driver fault.
  • Motor overload/blocked rotation.
  • Check power supply.
  • Verify wiring against diagram.
  • Test or replace stepper motor driver.
  • Ensure pump head is not jammed and tube is correctly installed.

10. User Tips

  • Driver Compatibility: Ensure you use a stepper motor driver compatible with the BP300's voltage (12V/24V) and current requirements for optimal performance.
  • Tube Life: To maximize pump tube life, operate the pump at the lowest effective rotational speed for your application.
  • Regular Checks: Periodically check the pump tube for signs of wear, cracking, or hardening, especially when handling corrosive liquids or operating at extreme temperatures.
  • Mounting: Securely mount the pump to a stable surface to minimize vibration and noise during operation.

11. Warranty and Support

LEIRONG products are manufactured under strict quality control standards. For detailed warranty information and technical support, please refer to the official LEIRONG website or contact your local distributor.

A comprehensive user manual in PDF format is available for download: LEIRONG BP300 User Manual (PDF).

For further inquiries, you may contact the manufacturer directly:

  • Contact Person: Alex
  • Tel/WeChat: 15316363092
  • E-mail: 15316363092@163.com
  • Company: Lei Rong Fluid Tech (Shanghai) Co.,Ltd.
  • Website: www.lrfluid.com

© 2023 LEIRONG. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.