The Jebao DCS Series Adjustable Submersible Water Pump is an advanced, energy-efficient pump designed for various aquatic applications, including aquariums, fish tanks, and flow fountains. Featuring an innovative electronic motor, it offers significant energy savings and precise control over water flow. This manual provides essential information for the safe and effective installation, operation, and maintenance of your Jebao DCS pump.

Jebao DCS Series pump and controller with features like energy saving, electronic control, amphibious, marine, and fresh water compatibility.
Jebao DCS Series pump and controller highlighting key features.

2. Key Features

  • Energy Saving: High-performance electronic motor design, offering up to 65% energy savings with new frequency conversion technology.
  • Intelligent Control: Equipped with an adjustable controller for precise flow rate management.
  • Dry-Running Protection: IC electronic detection automatically powers off the pump when no water is detected, preventing damage.
  • Durable Construction: Features a wear-resistant ceramic shaft for extended operational life.
  • Amphibious Design: Suitable for both submersible and external (in-line) applications.
  • Quiet Operation: Engineered for super quiet performance.
  • Feeding Mode: One-click pause function to temporarily stop the pump for 10 minutes during feeding.
  • Versatile Use: Ideal for marine and freshwater aquariums, as well as flow fountains.
Image showing the pump with a blue glow and circuit board graphics, emphasizing energy saving up to 65% and new frequency conversion technology.
Energy saving up to 65% with new frequency conversion technology.
Image of the pump partially submerged in water, with text 'AMPHIBIOUS BOTH ARE SUPER QUIET' and 'IC electronic detection water-free dry-running and locked-rotor protection functions'.
Amphibious design with dry-running and locked-rotor protection.

3. Package Contents

Please check the package to ensure all items are present and undamaged:

  • Jebao DCS Series Water Pump
  • DC Pump Controller
  • Filter Cage (Front Grille)
  • Various Nozzle Connectors/Adapters
  • O-rings/Seals
  • Power Adapter (DC 24V)
All components of the Jebao DCS pump system laid out: the pump, the controller, a filter cage, various hose barb fittings, and O-rings.
Contents of the Jebao DCS Series pump package.
Image showing various hose barb adapters for different pump models (DCS-7000-12000, DCS-5000, DCS-3000-4000, DCS-2000).
Adapters are included to connect to most common water pipe sizes.

4. Specifications

Jebao DCS Series Pump Specifications
Model Voltage Watts Q max. (l/h) H max. (m) In / Out (Ømm)
DCS-1200DC 24V1212001.5Out Ø25
DCS-2000DC 24V2020002.2Out Ø25
DCS-3000DC 24V2532002.8Ø20 25
DCS-4000DC 24V3040003.2Ø20 25
DCS-5000DC 24V4050003.5Ø20 25 32 38
DCS-7000DC 24V5572004.0Ø20 25 32 38

General Specifications:

  • Material: Stainless steel (shaft)
  • Fixed Form: Sitting
  • Power Source: Charge (DC 24V)
  • Battery Included: No
  • High-concerned chemical: None
  • Origin: Mainland China
Specifications diagram showing Square Wave Technology, 8/10 stage speed control, feeding function, low voltage DC supply, Fe2O3 magnet rotor, wear-resistant anti-corrosion ceramic shaft, and a connection diagram for the pump and controller.
Detailed specifications and connection diagram.

5. Setup and Installation

  1. Unpack: Carefully remove all components from the packaging. Inspect for any damage.
  2. Assemble Nozzles: Select the appropriate nozzle connector for your tubing size and attach it to the pump's outlet. Ensure O-rings are properly seated for a watertight seal.
  3. Positioning: The pump can be used submersibly or externally. For submersible use, place the pump securely at the desired location in your tank or sump. For external use, ensure it is placed on a stable, level surface. The base features anti-slip shock absorber nails for stability.
  4. Connect Controller: Connect the pump's cable to the DC Pump Controller.
  5. Power Connection: Connect the power adapter to the DC Pump Controller, then plug the adapter into a suitable power outlet. Ensure the voltage matches the pump's requirements (DC 24V).
  6. Wiring Diagram: Refer to the connection diagram below for proper wiring.
Wiring diagram showing the pump connected to the power adapter, which then connects to the DC pump controller. The controller has buttons for adjustment and a display.
Connection diagram for the Jebao DCS pump system.
Image showing the pump's base with anti-slip shock absorber nails and how it can be easily removed.
Easy-to-remove base with anti-slip shock absorber nails.

6. Operation

6.1. Power On/Off

Once connected to power, the pump will start operating. To turn off, disconnect from the power source.

6.2. Flow Adjustment

The DC Pump Controller allows you to adjust the water flow rate. The DCS2000/3000 models feature 8-speed adjustment, while DCS4000-12000 models offer 10-speed adjustment.

  • Use the '+' button to increase the flow rate.
  • Use the '-' button to decrease the flow rate.
  • The indicator lights on the controller will show the current speed setting.
DC Pump Controller showing '+' and '-' buttons for 10-speed flow adjustment, and a 'FEED' button. Indicator lights show the current speed.
DC Pump Controller for intelligent flow adjustment.

6.3. Feeding Mode

The pump features a convenient 10-minute pause/feeding function:

  • Press the 'FEED' button on the controller. The pump will pause operation for 10 minutes.
  • This allows fish to feed without food being immediately swept away by the current.
  • After 10 minutes, the pump will automatically resume its previous operation mode.
Image illustrating the one-touch feeding function, with the pump stopping for 10 minutes to allow fish to eat without food being blown away.
One-touch feeding function for convenient fish feeding.

6.4. Controller Lock/Unlock

To prevent accidental changes to settings:

  • Lock: Long press the '+' or '-' button for approximately 2 seconds until the button stops flashing. The LED lights will flash at the current speed.
  • Unlock: Long press the '+' or '-' button again until the LED lights stop flashing.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your Jebao DCS pump.

  1. Disassembly: The pump is designed for easy disassembly for cleaning.
    • For DCS2000-4000 models, the front grille can be rotated to detach.
    • For DCS5000 and above, the front grille is fixed with screws and can be removed by unscrewing.
    • The pump base is also easy to remove for thorough cleaning.
  2. Cleaning: Periodically clean the pump, impeller, and filter cage to remove any debris, algae, or mineral buildup. Use a soft brush and clean water. Do not use harsh chemicals.
  3. Impeller Inspection: Inspect the ceramic shaft and impeller for wear or damage. The wear-resistant ceramic shaft is designed for long life, but replacement may be necessary if performance degrades.
  4. Reassembly: After cleaning, reassemble all parts carefully, ensuring all seals are correctly in place.
Image showing the front grille of the pump and indicating it is easy to install and remove.
Easy to install and remove front grille for cleaning.
Diagram showing how to disassemble the pump: DCS5000 and above are fixed with screws, while DCS2000-4000 can be rotated and detached.
Disassembly methods for different DCS pump models.
Close-up image of the pump's ceramic shaft and impeller, highlighting its wear-resistant quality.
Wear-resistant ceramic shaft for longer service life.

8. Troubleshooting

The controller's indicator lights can help diagnose common issues:

Controller Status and Solutions
Controller Working Status Abnormal Indication Solution
Over voltage, under voltage Red dots on controller display Check the input power supply voltage.
Controller overheating Red dots on controller display Check whether the controller is in direct sunlight or a high-temperature environment. Relocate if necessary.
Water pump stuck Red dots on controller display Check whether the water pump has foreign objects stuck in the impeller or wiring errors. Clean the pump.
Pump idling for a long time Red dots on controller display Check whether the water pump is idling (running without water). Ensure the pump is fully submerged or has water flow for external use.
Controller working current is abnormal Red dots on controller display Check for a short circuit in the wiring of the water pump or if the controller itself is abnormal.
Key lock or unlock issue Long press '+' or '-' button for ~2s, button stops flashing after 2 flashes, and the button lock or unlock LED flashes at current speed. If long press does not flash, the key may be damaged. If the key is unresponsive, contact support.
DC Pump Controller with indicator lights showing red dots for abnormal status, and text explaining troubleshooting steps for various issues like over voltage, overheating, pump stuck, idling, and abnormal current.
Controller display and troubleshooting guide.

9. User Tips

  • Placement: Ensure the pump is placed in a location where it can draw water freely and is not obstructed by substrate or decorations.
  • Cable Management: Securely route the power cable to prevent accidental disconnections or damage.
  • Regular Checks: Periodically check the pump's flow rate and listen for unusual noises, which could indicate debris or wear.
  • Water Quality: Maintaining good water quality can reduce the frequency of pump cleaning.

10. Warranty and Support

For warranty information, technical support, or replacement parts, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.