1. Introduction
The JUNCTEK KG-F Series voltage and current meter is an advanced coulomb meter designed to accurately measure various electrical parameters. This device can monitor voltage, current, power, charge and discharge Ampere-hour (AH) value, Watt-hours (WH), and time. It also features configurable protection functions such as over-voltage, under-voltage, over-current, over-power, over-temperature, and time-limit protection. The meter automatically identifies the direction of current flow and displays real-time battery capacity on a high-definition color LCD screen.
Video 1.1: Unboxing and overview of the KG-F Series components.
2. Key Features and Advantages
- High-Definition Color LCD: The display module features a 2.4-inch high-definition color LCD screen for clear data visualization. Silicone buttons ensure smooth operation and fast response.
- Automatic Current Direction Recognition: The product automatically detects and indicates current direction. Green color for charging current, blue for discharging current.
- Wide Battery Compatibility: Suitable for various battery types including ternary lithium, lead-acid, and lithium phosphate batteries, provided they are within the voltage measurement range.
- Pure Copper Shunt: The shunt and screws are constructed from pure copper, ensuring excellent electrical conductivity, minimal heat generation, and low power consumption, preserving battery life in standby mode.
- Open-Source Communication Protocol: Utilizes 485 communication, allowing for secondary development with tools like serial port assistants. Supports control of up to 99 meters by switching communication addresses.
- Mobile APP Control: Connect via Bluetooth to a dedicated mobile application. The APP allows viewing of all relevant data, real-time and historical curves, and configuration of all meter functions.
- Data Logging and Export: The mobile APP supports viewing real-time and historical voltage and current curves, and enables exporting historical data for analysis.
- Comprehensive Protection Functions: Configurable over-voltage (OVP), under-voltage (LVP), over-current (OCP), over-power (OPP), and external over-temperature (OTP) protections. When a parameter exceeds its set limit, the instrument's output state can be turned off (requires a relay) to prevent equipment damage. Protection recovery time and delay time are adjustable.
- Self-Calibration Function: Includes a self-calibration feature to maintain accuracy of current and capacity values over extended periods of operation.
- Flexible Data Management: Ampere-hour, Watt-hour, and time data can be cleared during measurement without affecting subsequent readings. Voltage and current values can be fine-tuned for precise capacity measurement.

Image 2.1: Overview of accurately measured parameters by the KG-F Series meter.

Image 2.2: The KG-F Series meter is compatible with various battery types and applications.

Image 2.3: Mobile APP interface for Bluetooth connection, remote operation, data recording, and curve display.

Image 2.4: Visual representation of the comprehensive protection features.
3. Package Contents
Please verify that all items listed below are included in your package:

Image 3.1: Visual representation of the package contents.
- Display Module x 1
- Measuring Module x 1
- Sampler (Shunt) x 1
- Sampler Mounting Plate x 1
- Temperature Sensor x 1
- 3P Terminal x 1
- 3m Communication Cable x 1
- 3P Connection Cable x 1
- 4P Connection Cable x 1
- Screw x 4
- Spacer x 4
4. Technical Specifications
| Parameter | KG105F | KG110F | KG140F | KG160F | KG610F |
|---|---|---|---|---|---|
| Sampling method | Shunt | Shunt | Shunt | Shunt | Shunt |
| Voltage measurement range (External power supply) | 0-120V | 0-120V | 0-120V | 0-120V | 0-600V |
| Voltage measurement range (Self-powered) | 10-120V | 10-120V | 10-120V | 10-120V | 10-120V |
| Voltage resolution | 0.01V | 0.01V | 0.01V | 0.01V | 0.01A |
| Current measurement range | 0~50A | 0~100A | 0~400A | 0~600A | 0~100A |
| Current resolution | 0.01A | 0.01A | 0.1A | 0.1A | 0.01A |
| Relay | optional | ||||
| Temperature measurement range | -20-120℃ | ||||
| Capacity display range | 0%~100% | ||||
| Power measurement range | 0~72KW | ||||
| Power resolution | 0.01W | ||||
| AH measurement range | 0~9999.99AH | ||||
| Capacity resolution | 0.001AH | ||||
| Watt-hour measurement range | 0~9999.99kWH | ||||
| Watt-hour accuracy | 0.001WH | ||||
| Time measurement range | 0~999:59:59S | ||||
| Time resolution | 1 second | ||||
| Bluetooth communication distance | 10m | ||||
| Voltage accuracy | ±2%+3 characters | ||||
| Current accuracy | ±5%+10 characters | ||||
| Sampling rate | 1 time / second | ||||
| Measuring module power consumption | About 0.4W | ||||
| Display module power consumption | About 0.5W | ||||
| Over power protection | 0-99999.99W | ||||
| Negative overcurrent protection | 0~50A/100A/400A/600A | ||||
| Forward overcurrent protection | 0~50A/100A/400A/600A | ||||
| Overvoltage protection | 0~120V/600V | ||||
| Undervoltage protection | 0~120V/600V | ||||
| External over temperature protection | 0-120℃ | ||||
| Protection recovery time | 0-99s | ||||
| Enter standby time | 0-60s | ||||
| Delay time setting | 0-99S | ||||
| Mailing address | There are 99 P01-P99, P00 is the broadcast address | ||||

Image 4.1: Dimensions of the measuring module and shunt.

Image 4.2: Details of the pure copper shunt construction.
5. Setup and Installation
5.1 Wiring Diagrams
Proper wiring is crucial for accurate measurement and safe operation. Refer to the diagrams below for connection instructions.

Image 5.1: Self-Powered Wiring Diagram. The measuring module draws power directly from the battery being measured.

Image 5.2: External Power Supply Wiring Diagram (top) and External Power Supply Wiring Diagram with Relay Control (bottom). Note: External power supply voltage should match the relay's working voltage (e.g., 12V or 24V).
5.2 Bluetooth APP Connection
- Download the official JUNCTEK APP from your mobile device's app store.
- Ensure your KG-F Series meter is powered on.
- Enable Bluetooth on your mobile device.
- Open the JUNCTEK APP and follow the on-screen instructions to search for and connect to your device.
- Once connected, you can view real-time data, historical curves, and configure settings remotely.
6. Operating Instructions
6.1 Display Overview
The 2.4-inch color LCD displays various parameters:
- Voltage (V): Current voltage reading.
- Current (A): Current flow. Green indicates charging, blue indicates discharging.
- Power (W): Real-time power consumption/generation.
- Ampere-hour (AH): Accumulated charge/discharge capacity.
- Watt-hour (WH): Accumulated energy consumption/generation.
- Time: Elapsed time of operation.
- Temperature (°C): External temperature reading (if sensor connected).
- Battery Percentage: Visual indicator of remaining battery capacity.
6.2 Button Functions
The display module features several buttons for navigation and setting:
- SET: Enters the settings menu or confirms a setting.
- UP/DOWN Arrows: Navigates through menu options or adjusts parameter values.
- OK: Confirms selection or exits a menu.
6.3 Setting Protection Parameters
Access the settings menu using the 'SET' button to configure protection limits:
- OVP (Over Voltage Protection): Set the maximum allowable voltage.
- LVP (Low Voltage Protection): Set the minimum allowable voltage.
- OCP (Over Current Protection): Set the maximum allowable forward current.
- NCP (Negative Over Current Protection): Set the maximum allowable reverse (discharge) current.
- OPP (Over Power Protection): Set the maximum allowable power.
- OTP (Over Temperature Protection): Set the maximum allowable external temperature.
- Protection Recovery Time: Time delay before the output automatically recovers after a protection event.
- Delay Time Setting: Time delay for certain functions or protection triggers.
Use the UP/DOWN arrows to adjust values and SET/OK to confirm.
6.4 Clearing Data
To clear accumulated AH, WH, or time data, navigate to the relevant display screen or settings option and use the appropriate button combination (refer to the on-screen prompts or detailed manual for specific steps).
6.5 Self-Calibration
The meter includes a self-calibration function to maintain accuracy. Consult the detailed manual or APP interface for instructions on initiating and completing the self-calibration process. This may involve fine-tuning voltage and current values.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the display module. Avoid using abrasive cleaners or solvents that could damage the screen or casing.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.
8. Troubleshooting
- No Display/Power: Check all power connections. Ensure the external power supply (if used) is within the specified voltage range (10-30V DC).
- Inaccurate Readings: Verify all wiring connections are correct and secure, especially the shunt. Perform a self-calibration if available. Ensure the battery capacity setting in the meter matches the actual battery capacity.
- Protection Triggered (e.g., OVP, LVP, OCP): Check the parameter that triggered the protection. Adjust the load, charger, or battery condition as necessary. Review and adjust the protection limits in the settings menu. If a relay is used, ensure it is functioning correctly.
- Bluetooth Connectivity Issues: Ensure Bluetooth is enabled on both the meter and your mobile device. Make sure the meter is within the 10m communication range. Restart both the meter and your mobile device if connection problems persist.
- APP Not Displaying Data: Confirm the meter is successfully connected via Bluetooth in the APP. Ensure the APP is up-to-date.
9. User Tips
- Double-Check Wiring: Always verify your wiring against the provided diagrams before powering on the device to prevent damage.
- Utilize the Mobile App: The mobile application offers enhanced control and data visualization, including real-time and historical curves. Use it to monitor performance and adjust settings conveniently.
- Configure Protections: Take advantage of the comprehensive protection features (OVP, LVP, OCP, etc.) to safeguard your electrical equipment and batteries. Set these limits according to your specific battery and system requirements.
- Regular Calibration: Although the device has a self-calibration function, occasional manual checks or recalibration can ensure long-term accuracy, especially after significant changes in your setup.
10. Warranty and Support