FD SM8-WLTE

Contents

SM8-WLTE 4G LTE 8 Channel Relay Controller User Manual

Model: SM8-WLTE | Brand: FD

1. Overview

The FD SM8-WLTE is a smart 4G controller designed for remote ON/OFF switching of up to 8 channels, suitable for various applications including gate openers, motor control, and environmental management. It features remote control capabilities via SMS, dial, web, and a dedicated mobile application, ensuring control without distance limitations. The device also supports temperature and humidity monitoring and control when connected to compatible sensors.

Key Features:

  • Remote Control with no distance limitation.
  • 4G Data network Remote Control via App and PC web interface.
  • SMS and Call Control: Supports SMS commands for all 8 relay outputs and up to 99 authorized numbers for call control (first relay only).
  • 8 Relay Outputs: Each relay supports 10A/30VDC or 10A/250VAC.
  • Support for Temperature and Humidity Control (sensors sold separately).
  • Scheduled / Timing Control for automated operations.
  • Industrial-grade design with aluminum alloy material.

Applications:

The SM8-WLTE controller is versatile and can be used in various settings, including:

  • Farm automation (e.g., irrigation, ventilation).
  • Hennery and animal husbandry.
  • Machine room monitoring and control.
  • Electric garage door and gate openers.
  • Greenhouses, breweries, and wine cellars.
  • Power distribution rooms.

The controller operates in two primary modes: SMS Call mode and 4G Data Network Mode, offering flexibility in how you manage your devices.

2. Package Contents

Upon opening your SM8-WLTE package, please verify that all the following items are included:

  • SM8-WLTE Smart 4G Controller Unit
  • 4G Antenna
  • Sensor Cable (for connecting external sensors)
  • Extended Keyboard Port PCB (for manual control)
  • Power Adapter (12V DC, not explicitly shown but implied for operation)

Note: Temperature and humidity sensors are typically sold separately.

SM8-WLTE Controller and accessories
Figure 2.1: SM8-WLTE Controller with included accessories (Antenna, Sensor Cable, Keyboard PCB).

3. Specifications

AttributeValue
Brand NameFD
Communication methodOther (4G LTE, SMS, APP, Web)
OriginMainland China
4G FDD-LTE BandsB1/B3/B5/B7/B8/B20
Relay Output8 channels, 10A/30VDC, 10A/250VAC
Sensor InterfaceSupports Temperature & Humidity Sensors
Temperature Detection Range-40 to +120 centigrade degree
Relay TypeNormal Closed or Normal Open
Control ON/OFFSMS or 4G Data Network App
Call ControlOnly available for the first relay output
Typical UsageWindow, Gate, Garage Opener, Greenhouse, Brewery, Wine Cellar, Power Distribution Room

4. Setup Guide

4.1. Device Layout and Indicators

SM8-WLTE Key and Indicator Diagram
Figure 4.1: SM8-WLTE Key and Indicator Diagram.

SIG Indicator: One flash per second means entering the GSM network. One flash in two seconds means entering the 4G network. APP control is allowed only when connected to 4G network.

SET Button: Short press to set the master number. Long press for 8 seconds to reset the system (SIG will flash 5 times if reset is successful).

4.2. Insert SIM Card

Before powering on the device, insert a valid 4G SIM card into the SIM card slot. Ensure the SIM card does not have a PIN code enabled; if it does, please disable it using a mobile phone before insertion.

SIM Card Insertion Diagram
Figure 4.2: SIM Card Insertion and Removal.

4.3. Connect to 4G Network

After inserting the SIM card and powering on the controller, the SIG LED will flash. When the SIG LED flashes every 2 seconds, it indicates a successful connection to the 4G network. If the SIG LED remains constantly on, it means there is no network access. In this case, check the SIM card installation, antenna connection, or contact your SIM service provider.

4G Network Connection Status
Figure 4.3: SIG LED indicating 4G network status.

4.4. Set Device Password

The factory default password is 0000. You can change it via SMS. Passwords must consist of 0-9 Arabic numerals (no letters or symbols).

SMS Command Format: SN+password(4 numbers)+NEW+new password

Example: To change the password from 0000 to 1234, send the SMS: SN0000NEW1234. You will receive a confirmation SMS: NEW SN SETOK NEW SN IS 1234 (New password).

Setting Password via SMS
Figure 4.4: Setting the controller password via SMS.

4.5. APN Setup (for Network Mode)

APN (Access Point Name) settings are crucial for the controller to access the 4G data network. The APN must be correctly configured for your country's network provider.

Factory Default APN: The default APN is internet with an empty username and password (APN:internet user: password:).

Check Current APN: Send SMS command: CHECK. You will receive: APN:internet user: pass:.

Set Custom APN:

SMS Command Format: SN+password+APN+length of APN+APN content,length of user+user content,length password =password content

Example 1 (with user/password): For APN: datelo.com.br, user: algar, password: 12345, send: SN0000APN13=datelo.com.br05=algar,05=12345. You will receive: APN:datelo.com.br user:algar pass:12345.

Example 2 (empty user/password): For APN: cmnet, user: (empty), password: (empty), send: SN0000APN05=cmnet,00=,00=0. You will receive: APN:cmnet user: pass:.

5. Operating Instructions

5.1. Control Modes Overview

4G Controller Control Methods
Figure 5.1: The SM8-WLTE supports SMS, Dial, Web, and APP control.

5.2. SMS Control

The controller can be managed by sending specific SMS commands to its SIM card number. The default password is 0000.

5.2.1. ON/OFF Control:

  • Turn ON: SN+PASSWORD+ON (e.g., SN0000ON)
  • Turn OFF: SN+PASSWORD+OFF (e.g., SN0000OFF)

5.2.2. Check Status:

  • Check all relay status: SN+PASSWORD+COM (e.g., SN0000COM)
  • Check specific relay status: SN+PASSWORD+COM+channel number (e.g., SN0000COM1 for channel 1)

5.2.3. Master Numbers (up to 99 groups):

  • Cancel SMS feedback: SN+PASSWORD+DL+O/C (O is letter)
  • Default function: SN0000DLO
  • Power on/off remind SMS: SN0000DLO, receive REMINDED NUMS: 1:+8613099999999 2:3: 4:

5.2.4. Relay Memory (PAM/PAF Command):

  • PAM (Power Again Memory): Factory default. Relay remains in the state before power off. Send: SN0000PAM.
  • PAF (Power Again OFF): Relay is always forced to be off after power on. Send: SN0000PAF.

5.2.5. Temperature Control (up to 8 groups):

Format: SN+password+LE/GR(LE is less than,GR is greater than)+Group number(01-08)+P/N(P for +,N for -)******(****** is the thousands, hundreds, tens, ones and decimal places of the temperature)+N/F/X(N for ON,F for OFF, X for ignore)

  • Example: To turn on SW1-SW8 when temperature is below +25.0 degrees, send: SN0000LE01P00250NNNNNNNN. Equipment will reply: T01:LE +0025.0C SW1-8:NNNNNNNN.
  • Delete: SN+password+DET+**(for the Group number) (e.g., SN0000DET01).
  • Check: SN+password+GTS+***(***is group number) (e.g., SN0000GTS01).
  • Correction: SN+password+CT+P/N(P:Increase,N:Reduced)+**(**00-50, min 0.1 degrees) (e.g., SN0000CTN10 for -1.0C).
  • Cancel SMS notification: SN+password+TLO.
Detailed SMS Commands for Temperature Control
Figure 5.2: Detailed SMS commands for temperature control.

5.2.6. Humidity Control (up to 4 groups):

Format: SN+password+LE/GR(LE is less than,GR is greater than)+group number(01-04)+H***(***is the hundreds, tens, ones places of humidity)+N/F/X(N for ON,F for OFF, X for ignore)

  • Example: To turn on SW1-SW8 when humidity is below 68%, send: SN0000LE01H068NNNNNNNN. Equipment will reply: H01:LE 068% SW1-8:NNNNNNNN.
  • Delete: SN+password+DEH+**(for the Group number) (e.g., SN0000DEH01).
  • Check: SN+password+GHS+***(***is group number) (e.g., SN0000GHS01).
  • Correction: SN+password+CH+P/N (P:Increase, N:Reduced)+**(**00-20%, min 1%) (e.g., SN0000CHN10 for -10%).
Detailed SMS Commands for Humidity Control
Figure 5.3: Detailed SMS commands for humidity control and SMS alarm activation.

5.2.7. Activate Input SMS Alarm:

  • Activate: SN+PASSWORD+RLO
  • Disable: RLC

5.2.8. KT Command (Set SMS Feedback Length):

This command sets the length of feedback SMS messages. The default mode is closed. If you need to set it, use the format:

SN+password+KT+length of country code+S+country code+L+length of number+country code

  • Example 1 (France): Country code is 33. Length of phone number is 10. Send: SN0000KT2S33L09.
  • Example 2 (Russia): Country code is 7. Length of phone number is 10. Send: SN0000KT4S007L10.

5.2.9. OTG Command (Trigger by SMS):

SN + password + OTG+C/X (C: trigger; X: ignore)

Example: To trigger the 1st and 2nd channels, send: SN0000OTGCCCXXXXXX.

Detailed SMS Commands for KT, COM+, OTG, Dial, Button Control
Figure 5.4: Additional SMS commands and control methods.

5.3. Dial Control

After setting a master number via SMS, you can control the first relay by simply calling the controller's number. The controller will automatically hang up after receiving the call.

  • Turn ON/OFF 1st channel: Call the controller.
  • Set to default mode: SN0000TXC.
  • Activate feedback SMS for dial control: SN0000CBO.

5.4. Button Control (Extended Keyboard Port)

The controller can be manually operated using an external keyboard connected to the dedicated keyboard port. Short presses on the SW1-SW8 keys will toggle the status of the corresponding 1st-8th channels.

5.5. Mobile APP Control

The SM8-WLTE can be controlled via a dedicated mobile application called "WLTE Control".

5.5.1. Downloading the APP:

APP Download QR Codes and Overview
Figure 5.5: QR codes for downloading the WLTE Control APP.

5.5.2. APP Interface and Functions:

WLTE Control APP Screenshots
Figure 5.6: Screenshots of the WLTE Control APP interface.
  • Temperature Trigger Control: Set thresholds to automatically activate/deactivate equipment. For example, start an exhaust fan when temperature is above 30°C, or a heater when below -10°C. (Requires temperature sensor).
  • Timing Control: Schedule up to 24 groups of ON/OFF operations. For instance, turn on a kettle at 8:00 AM daily or a water heater on specific days.
  • Push Notifications: Receive real-time alerts on your phone regarding device status changes or triggered events.
  • Email Pushing: Configure the device to send email notifications when specific conditions (e.g., temperature thresholds) are met.
APP Temperature Trigger Control
Figure 5.7: Example of APP temperature trigger control.
APP Timing Control
Figure 5.8: Example of APP timing control settings.
APP Push Notifications
Figure 5.9: APP push notifications for device status.
Email Pushing Notification
Figure 5.10: Email notifications for triggered events.

5.6. Web Control

The SM8-WLTE controller can also be managed through a web browser on a PC, offering centralized control of your equipment.

Web Control Interface
Figure 5.11: Web control interface for managing the SM8-WLTE.

5.7. Input Function Demonstration

The following video demonstrates how to use the input function to control a relay and receive notifications.

Video 5.1: Demonstration of SM8 Input Function, showing how connecting/disconnecting an input activates/deactivates a relay and triggers simultaneous SMS, APP, and email notifications.

6. Maintenance

  • Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Connections: Periodically check all wiring connections (power, relays, sensors, antenna) to ensure they are secure and free from corrosion.
  • SIM Card: Ensure the SIM card is active and has sufficient credit/data plan for continuous operation, especially for SMS and 4G data functions.
  • Firmware Updates: Check the manufacturer's website or APP for any available firmware updates to ensure optimal performance and security.
  • Environmental Conditions: Operate the device within its specified temperature and humidity ranges to prevent damage.

7. Troubleshooting

  • No Network Access (SIG LED always on):
    - Check if the SIM card is correctly inserted.
    - Ensure the 4G antenna is securely connected.
    - Verify that the SIM card is active and has a valid data plan/credit.
    - Confirm that the APN settings are correct for your network provider (refer to Section 4.5).
  • SMS Commands Not Working:
    - Double-check the SMS command format and ensure the password is correct.
    - Verify that the SIM card has sufficient credit to send SMS messages.
    - Ensure the master numbers are correctly set if using specific features.
  • APP Not Connecting/Controlling:
    - Confirm the device has a stable 4G network connection (SIG LED flashing every 2 seconds).
    - Check your phone's internet connection.
    - Ensure the APN settings on the controller are correct.
    - Verify that the device is added correctly in the WLTE Control APP.
  • Relays Not Responding:
    - Check the power supply to the controller.
    - Inspect the wiring to the relays and the connected equipment.
    - Ensure the control commands (SMS, APP, Web) are being sent correctly and acknowledged by the controller.
  • Temperature/Humidity Control Issues:
    - Ensure the external sensor is correctly connected to the sensor interface.
    - Verify that the temperature/humidity thresholds and control logic are correctly configured in the APP or via SMS commands.

8. User Tips

  • SMS Command Clarity: When using SMS commands for ON/OFF or other functions, always double-check the exact syntax, including the password and any specific channel numbers or parameters. A common user query relates to the 'sending formula for locking and unlocking', which refers to the precise SMS commands for controlling relays.
  • APN Configuration: For reliable 4G data network control via the APP or web, ensure your APN settings are accurately configured for your local mobile network provider. Incorrect APN settings are a frequent cause of connectivity issues.
  • Sensor Integration: If utilizing temperature and humidity control, remember that the sensors are typically purchased separately. Ensure they are compatible and correctly wired for accurate readings and automated actions.
  • Security: Change the default password immediately after initial setup to prevent unauthorized access.

9. Warranty and Support

The SM8-WLTE controller typically comes with a 1-year warranty from the date of purchase. For any technical assistance, troubleshooting, or warranty claims, please contact the seller, fdsmart Store. All inquiries are generally answered within 24 hours.

For further information or to access the latest resources, please refer to the official product page or contact fdsmart Store directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.