VOTOL EM50-4

Rate this product if you’ve used it
Contents

VOTOL EM50-4 80A 1KW-1.5KW Hub Mid-Drive Controller Motherboard User Manual

Model: EM50-4

1. Introduction

This manual provides detailed instructions for the VOTOL EM50-4 series controller, covering software installation, parameter adjustment, and troubleshooting. Please read this manual carefully before operation to ensure maximum utility and safe use of the software.

2. Safety Information and Disclaimer

It is forbidden for non-specialists to use this product without proper guidance.

For the IV generation of EM series controller program updates and parameter adjustment, operations must only be performed by professional and technical personnel. Unauthorized application updates or parameter adjustments without written permission from the manufacturer are strictly prohibited. The manufacturer will not be responsible for any accidents resulting from unauthorized use or modification of this software.

Note: If the voltage parameter is adjusted without hardware support, the controller will be damaged.

Please do not fill in values out of range for current limits, as this will damage the controller.

The flux weakening value marked in blue is for motor running noise and shock adjustment. If the motor experiences shock, you can set this data lower than 800. It will not reduce speed. The yellow mark is a Capacitor protection value; modification is not recommended.

When setting flux weakening values, ensure they are within range to prevent motor demagnetization and damage.

3. Product Overview

3.1 Package Contents

  • 1 pcs EM50-4 Controller with function cables
  • 1 pcs USB cable for programming

3.2 Default Functions

  • Hall Plug
  • Reverse
  • Low Brake 0V
  • Throttle (0-5V)
  • High Brake 12V
  • Ignition
  • One-LIN/Hall Speed Sensor
  • Program Port
  • Three Speed
  • Sport Model
  • Parking
  • Anti-Theft
  • Regen Charge
  • Flux Weaken Current

3.3 Product Images

VOTOL EM50-4 Controller with function cables and USB cable
VOTOL EM50-4 Controller with function cables and USB cable.
Side and bottom view of the EM50-4 controller
Side and bottom view of the EM50-4 controller.

4. Specifications

FeatureSpecification
ModelEM50-4 ECU sine wave controller
Available Battery Voltage48V-72V
Rated DC Current40A
Boost DC Current80A
Peak Phase Current170A
Max. Power5760W
Mosfets Detail12 FET
Matched Motor Rated Power800W-2000W
Max. Efficiency92%
Degree of WaterproofIP65
Flux Weakening Ratio150%
CertificationCE, CCC
Working CommunicationHall Sensor
Net Weight0.8kg
Dimensions (L x W x H)181mm x 94mm x 50mm
ProgrammableYes, by PC
MaterialAluminum Plastic
DesignProgrammable sine wave
OriginMainland China

4.1 Dimension Drawing

Dimension drawing of EM50-4 controller
Dimension drawing of EM50-4 controller, showing measurements: 181mm (length), 94mm (width), 50mm (height).

5. Setup and Installation

5.1 Software Installation (Windows 7/10 Only)

The programming software only supports Windows 7 and Windows 10. iOS and XP systems are not supported.

5.1.1 USB Driver Installation

  1. Download the "USB-to-serial-win 10-20150814" file and decompress it.
  2. Choose the suitable driver for your computer (32-bit or 64-bit). For non-Chinese PC systems, remove any Chinese characters from the file name if present.
  3. After installation, connect the USB cable to the controller and computer. If connection fails:
    • Right-click "My Computer" on the desktop, then select "Device Manager".
    • Navigate to "Ports (COM & LPT)".
    • Right-click the COM port with a "!" (exclamation mark) and select "Update software".
    • Choose "Browse my computer for driver software" and then "Let me pick from a list of device drivers on my computer".
    • Select "Prolific USB-to-Serial Comm Port Version: 3.3.2.102 [2008/9/24]".
    • Click "Next" to install and then "Finish".

5.1.2 Software Installation

For versions from 2018.7 onwards, only the USB driver needs to be installed, then the software can be opened directly. For older versions:

  1. Copy the `TeeChart5.ocx` file to the C drive root directory.
  2. Run the setup to register the file (e.g., allow installation if the software shows an intercept interface).
  3. After installation, run the `EM_V3` program.

5.2 Controller Connection

  1. Power on the controller, ensuring the ignition is closed.
  2. If your controller has CAN, click "CAN enable" in the software, then click "Open".
  3. Click the "Research" button, then choose the correct serial port from the device COM list (usually the last one). Click "Open series port"; the device status should show "Connected".
  4. Key on the ignition, then click "Connect" to the controller (it is recommended to click more than twice). The voltage parameter can be freely chosen based on the controller's hardware support.

5.3 Wiring Diagram

Detailed wiring diagram for EM50-4 controller
Detailed wiring diagram for EM50-4 controller, showing connections for throttle, brakes, ignition, programming port, anti-theft, and hall sensor wires. Key connections include: 1. High brake 12V, 2. One-LIN speedometer, 3. Parking, 4. One-click repair, 5. High speed, 6. Throttle signal, 7. Throttle negative, 8. Positive +5V, 9. Low brake 0V, 10. Sport, 11. Middle speed, 12. Low speed, 13. Reverse, 14. TXD, 15. RXD, 16. Ignition.

6. Operation and Programming

The controller's functions are configured via the programming software. The software interface is divided into several pages for different settings.

6.1 Software Interface Overview

Screenshot of the EM Controller Program Manual software interface
Screenshot of the EM Controller Program Manual software interface (LD-EM-V3), showing basic settings, port settings, and status display.

6.2 Basic Settings (Page 1)

6.2.1 Battery Voltage Adjustment

The voltage parameter can be freely chosen under the hardware support of the controller. Available options include 48V, 60V, 72V, 84V, 96V, 108V depending on the controller model (EM-30S, EM-50, EM-100, EM-150).

6.2.2 Controller Under-voltage and Soft Under-voltage Adjustment

Fill in the required under-pressure protection parameters and software under-pressure parameters:

  • Overvoltage(V): Set the threshold for hardware under-voltage protection.
  • Undervoltage(V): Set the threshold for software under-voltage protection (generally under-voltage + 3V).
  • Soft undervoltage(V): The range of under-voltage back to the difference (unadjustable). For example, if set to 63V for overvoltage and 1V for undervoltage variation, a 64V controller will recover to work.
  • Undervoltage variation: It is not recommended to change this value, as it can damage the battery and reduce its life due to excessive discharge.

6.2.3 Controller Battery Current and Phase Current Limited Adjustment

  • Battery Current: Adjust the controller battery current within the specified ranges for each model (e.g., EM-30S 48-60V ≤35A, EM-50 72V ≤50A).
  • Phase Current Limited Value: If this value limits the controller phase current output, it will limit the motor torque output. The biggest value is full power output; adjustment is generally not suggested.

6.2.4 Throttle Voltage Adjustment

  • Low protect: Indicates throttle error.
  • Start voltage: When this value is reached, the motor starts running.
  • End voltage: When this value is reached, the controller considers full voltage is reached (recommended to set 0.2V lower than actual torque voltage).
  • High protect: If this value is exceeded, a torque fault will be displayed.

6.2.5 Start Setting Adjustment (for tricycle gearbox only)

  • Start torque: Used for gear combination.
  • Combinative torque: Force of lifting after gear clearance is combined.
  • Rate of rise: Upward slope of motor torque.
  • Rate of decline: Downward slope of motor torque.

6.2.6 Controller and Motor Temperature Protection Function Adjustment

Settings for external temperature protection:

  • Start: Enter this function to limit motor torque based on temperature.
  • Over temp: Cuts off motor torque output.
  • Recovery: When motor temperature drops below the protection value, the throttle can be re-twisted to restore motor motivation.
  • Max: The motor's maximum temperature is 150°C.

6.3 Advanced Settings (Page 2)

6.3.1 Parameters Setting for Sport Mode (S Gear)

When the controller enters S gear sport mode, battery current increases, providing more power for climbing.

  • Current-Limiting(A): Adjust current limit for sport mode.
  • Flux-Weakening Value: Adjust for motor running noise and shock. If motor has shock, set lower than 800.
  • Automatic logout enablers: Enable/disable automatic exit from sport mode.
  • Logout time(S): Duration after entering S gear sport mode before auto-exit (optional).
  • Recovery time(S): Time to recover from S gear mode.

6.3.2 Downhill Electric Brake Assist (HDC/HHC)

This function helps maintain constant speed on steep slopes by stabilizing RPM. Enable "HDC Enable" and set the "HDC lowrst speed" value. For a 1000rpm motor, set between 1000rpm and 1200rpm (approx. 110%~120% of real RPM).

6.3.3 Speed Limit Setting

Enable "Speed limited enable" and set "Speed ratio(%)" from 0 to 100 percent to customize the controller's speed limit.

6.3.4 Flux Weakening & Three Speed Setting

  • Flux-Weakening compensation: Adjust this factor (suggested not to change). Default values are 34 for hub motors less than 40mm magnet, and 64 for other motors.
  • Three-speed settings: Set Low(%), Mid(%), Hige(%) ratios from 0-100%.
  • Mid Flux-Weakening Value: Data for motor start speed (set between 2000-6000). If flux weakening is not desired, set to 200-500.
  • Button/Switch 3 speed: Choose between button or switch control for three speeds.
  • Soft start enabled: Enable/disable soft start. Soft start grade (1-16) determines softness; lower value means softer start.

6.4 Motor Settings (Page 3)

6.4.1 Motor Pole Pairs

Correctly fill in the motor pole pair for accurate motor speed (RPM) acquisition.

6.4.2 Hall Phase Shift Angle Adjustment

Fill in the range (-180~180) for controller and motor phase adjustment. You can test values like -180, -120, -60, 0, 60, 120, 180. To change running direction, add or subtract 120 from your current data.

6.4.3 Speedometer Output

The controller supports two types of speedometer output: ONE-LIN and Hall speedometer. The choice depends on the vehicle's speedometer. ONE-LIN communication uses the xinsiwei agreement.

6.4.4 Moving Assist and Cruising Function

  • Moving Assist: Enable this function. The speed of the transfer assist is a percentage of the motor base speed (default 10%). Moving assist torque value 320 corresponds to 9-10N.m (varies by motor characteristics).
  • Cruise Function: Enable this function. To activate, maintain a certain throttle angle for more than 8 seconds. Any operation (e.g., braking, turning handle) will exit cruise mode.

6.4.5 Dual Voltage Adaptive Function

Enable this function for automatic switching between low and high voltage modes based on battery voltage thresholds (e.g., 48-60V switches below 49V to low volt mode, above 63.5V to high volt mode).

6.4.6 Reversing, EBS Setting, Low Brake Selection, Starting Safety Switch Function

  • Reversing Speed Limit (%): Adjust from 0-100% (do not exceed 30% to avoid accidents).
  • EBS Ratio (%): Adjust electronic brake force from 0-100%.
  • Low Brake Enable: When enabled, the original single-branch power-down function becomes a low-level brake.
  • Safety Switch Function: When enabled, the safety switch must be pressed before starting the vehicle.

6.5 Controller Status Display

The software provides a real-time display of the controller's working status, including RPM, Voltage, Current, Fault Code, Hall Fault, Brake status, Temperature, and more.

6.6 Port Setting Interface

This section allows configuration of specific port functions.

6.6.1 Hall Speed Setting

For EM30S/50S/100S/150S models, if matching with Hall Type Display, choose "IO" and "F", "13: Hall". For EM200S models, choose "IO" and "F", "13: Hall".

6.6.2 Three Speed Setting

For EM30S/50S/100S/150S models, when three speeds are achieved by switch, configure PD0 for low speed, PD1 for high speed, and PB3 for middle speed. For EM200S, PA0 for low speed, PB2 for high speed. For button-activated three speeds, PD1 is the e-gear button and PB3 is sport mode.

6.7 Remote Operation and Software Update

Remote operation and software updates should only be performed under the guidance of a company engineer. To update software, click "opening file", choose the ".bin" file, and click "download". A 100% completion indicates success.

If the controller cannot communicate, try brushing the bottom program:

  1. Close ignition.
  2. Open the debugging software, open the serial port (do not click "connect").
  3. Open ignition, open the "CAN.Bin" file.
  4. Then connect normally.

7. Troubleshooting (FAQ)

7.1 Software Cannot Be Installed

If the software fails to install, try changing your computer system language to English or Chinese, as it may be due to different C++ runtime versions, especially for some non-English PC systems.

7.2 Software COM Port Cannot Be Found

If your computer has COM information but the software doesn't show it, the driver is likely the problem. Re-research or install the "FT232 Driver" file.

7.3 Controller Self-Learning Work

The controller performs self-learning for "hall angle shift" data. Refer to the provided guides for other data.

7.4 Matching a New Brand Controller

For testing and adjustment, ensure proper connection of phase and hall wires. Set correct data for motor poles and hall shift. Hall shift is important and can be tested from -180 to 180. Refer to section 6.3.1 for detailed settings.

7.5 Parking Function Setting

The parking function can be activated by a button or switch. Configure the PC14 port in the software. Choose "SW" & "F" and momentarily connect your parking wire to any GND wire (or a button). The "P" gear should appear on your display. Alternatively, choose "LA" & "F" and connect your parking wire and GND to a switch.

7.6 Stop Twist Throttle, Motor Still Running

If the motor continues to run after releasing the throttle, try adjusting the hall shift data (e.g., change -60 to 120) and test different values. Refer to section 6.3.1.

7.7 How to Set Speed Limit

Choose an unused function wire (e.g., PB3 port) in the software and set it to "24: speed_limit". Then, on page 2 of the software, set your desired speed limit percentage. For a constant speed limit without a switch, connect the speed limit wire directly to GND.

7.8 Controller Fault or Hall Error

If the software shows a controller fault when connected to a PC but the controller runs fine on the road, there is no issue. If the controller cannot run and the software shows a hall error (with hall connected), check the plug connection. If the connection is good, test the hall voltage from the motor. Hall positive and negative should be 5V, and the three hall signal wires should have the same voltage. If not, the motor hall is faulty or damaged.

7.9 Test Controller Hall Error

To test for a controller hall fault:

  1. Connect the positive and negative battery terminals to the controller.
  2. Connect ignition and power on.
  3. Measure the positive and negative poles of the controller Hall. It should be around 5V. If the reading is different (e.g., 0.9V), the hall port is damaged.
Multimeter testing controller hall voltage
Multimeter testing controller hall voltage. Incorrect wiring of the hall plug can damage the hall port.

7.10 Reverse Function Not Working

If the reverse function wire is connected correctly and the display shows 'R' gear but the motor doesn't reverse, check your software parameters. Sometimes there might be two ports configured for reverse; remove one to empty it.

7.11 General FAQ from Seller

  • Q: About the functions and interfaces of the controller
    A: Most controllers are universal versions, not customized for a specific brand. Therefore, some auxiliary functions of the original vehicle (like speedometer display) may not work normally after installation. Most functional interfaces need modification, not plug-and-play. Before refitting, carefully check the function line on the original vehicle and the communication signal of the speedometer.

8. User Tips

  • Programming Speed: To program the controller for a specific speed, utilize the "Speed Limit Setting" feature described in section 6.3.3. You can set the desired speed ratio percentage.

9. Maintenance

Regularly check all wiring connections for secure fit and signs of wear or damage. Ensure the controller is kept clean and free from excessive dust or moisture, although it has an IP65 waterproof rating. Periodically review software settings to ensure they align with your motor and battery specifications. If any parameters are changed, save the configuration. For advanced diagnostics or persistent issues, refer to the troubleshooting section or consult a professional.

10. Warranty and Support

The manufacturer offers a 1-year warranty for motors and controllers. However, the buyer is responsible for return shipping costs for repairs or replacements. The warranty does not cover man-made damage. If you encounter any problems, please contact the seller for assistance.

If you lack knowledge in electric kit assembly, please exercise caution before purchasing, as man-made damage is not covered under warranty.

For further detailed instructions and diagrams, please refer to the official user manual PDF: VOTOL EM Controller Program Manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?