10A Active Balancer (4S-24S) 10A Active Balancer (4S-24S)

Contents

10A Active Balancer (4S-24S) User Manual

1. Introduction

This manual provides comprehensive instructions for the safe and efficient use of your 10A Active Balancer. This device is designed to balance the voltage of individual cells within a battery pack, extending battery life and improving overall performance. It is compatible with 4S to 24S Li-ion and LiFePO4 battery packs, making it suitable for various applications including electric vehicles, RVs, and energy storage systems.

10A Active Balancer unit and its internal board with a transformer.

Figure 1: 10A Active Balancer unit. Supports 4S, 8S, 16S, 20S, 24S Li-ion and LiFePO4 batteries, includes 18AWG cable.

2. Safety Warnings and Precautions

2.1. Safety Warning

  • WARNING: Stay away from children and avoid misoperation.
  • WARNING: Please do not disassemble or modify this product by yourself. Non-professional repairs may cause damage or safety accidents.

2.2. Precautions

  • Do not use in damp or dusty environments.
  • Avoid severe impact or vibration on the product.
  • The wrong connection will immediately blow the fuse and seriously damage the chip.
  • If the wiring order is reversed, the unit will burn down immediately.
  • Do not create a pressure difference of more than 0.7V and keep it for 10 minutes or longer, as this will damage the balancer.

3. Package Contents

Please check the package contents upon unboxing:

  • 1x 10A Active Balancer Unit
  • 1x Set of 18AWG Connection Cables

4. Specifications

FeatureSpecification
Applicable Battery Types3.7V Li-ion, 3.2V LiFePO4
Cell Count Support4S - 24S (minimum 4S)
Balancing TypeTransformer Active Energy Transfer
Balancing Efficiency96%
Max Balancing Current10000mA (10A)
Balancing Differential Pressure< 10mV
Trigger Condition (Adjacent Diff.)> 0.05V
Cut-off Condition (Adjacent Diff.)< 0.03V
Low Voltage Protection< 3V
Sleep Power Consumption800uA
Cable Size18AWG
Dimensions (20S/24S Model)120mm x 108mm x 29mm
Dimensions (4S/8S Model)63mm x 76mm x 21mm
Dimensions (17S Model)125mm x 88mm x 28mm
Dimensional drawings for 20S/24S, 4S/8S, and 17S balancer models.

Figure 2: Dimensions for various balancer models.

5. Setup and Wiring

Careful wiring is crucial to prevent damage to the balancer and battery pack. Always follow these instructions precisely.

5.1. General Wiring Guidelines

  • Always unplug the port before connecting the cables.
  • After connecting, test for any connection errors. Incorrect wiring will immediately blow the fuse and severely damage the chip.
  • Before welding the battery, remove the terminal block from the balancer, connect the battery wires to the terminal block, and then insert the terminal block into the balancer. The connection order for the wires is from left to right.
  • WARNING: If the wiring order is reversed, the unit will burn down immediately.
  • The green connector must be pulled out before wiring.
  • This balancer model must be fixed with the battery pack together; it cannot be removed and used with other battery packs. Doing so will damage the balancer.
Balancer unit with a screwdriver pointing to the removable terminal block.

Figure 3: Remove the terminal block before connecting wires. Connect wires from left to right.

5.2. Wiring Diagrams

The balancer supports downward compatibility, meaning it can be used with fewer cells than its maximum rating, down to a minimum of 4S.

Wiring diagrams for 4S and 8S battery configurations.

Figure 4: Wiring diagrams for 4S and 8S battery packs. Ensure correct polarity and cell connections.

5.3. Connecting Fewer Cells (e.g., 5S with an 8S Balancer)

When connecting fewer cells than the balancer's maximum capacity (e.g., a 5S pack to an 8S balancer), any unused connection points on the terminal block must be removed to prevent short circuits and damage.

Wiring diagram for a 5S connection, showing removal of unused terminals.

Figure 5: Example of a 5S compatible connection. Unused terminals must be removed to avoid short circuits.

5.4. Extended Connection (Multiple Balancers)

For very large battery packs or specific configurations, multiple balance modules can be connected in series. Connect the first balance module and the second balance module repeatedly with the battery from head to tail. More repetitions can lead to a better overall balancing effect for the entire group.

Wiring diagram for extended connection of two 8S modules.

Figure 6: Extended connection example using two 8S modules.

5.5. First Use Procedure

  1. Connect each balance cable carefully. Incorrect wiring will damage the balancer.
  2. Avoid frequent plugging and unplugging of the connector, as this can cause poor contact and affect the balance current.
  3. The balancer must be installed with the battery and fixed securely.
  4. After all balance cable connections are completed, the connector can be plugged in.
  5. For the first use, start charging the battery pack to enhance the balancing effect.

6. Operating Principles

The 10A Active Balancer utilizes a transformer feedback mechanism to achieve cell voltage equalization.

6.1. Balancing Mechanism

  • The transformer feedback system actively balances the cells.
  • The balance current increases proportionally with the differential voltage: approximately 1.2A for every 0.1V of differential voltage between adjacent cells.
  • The balance current for each string is not fixed but dynamically changes based on the differential pressure.
Internal view of the balancer board with transformer and capacitors.

Figure 7: Internal view of the balancer, illustrating the transformer feedback system.

6.2. Balancing Logic and Period

  • The entire battery group is balanced synchronously.
  • After a balancing cycle, the device will automatically enter a sleep mode for one hour.
  • After the sleep period, it re-detects the voltage differences to initiate the next balancing cycle if needed.
  • Balancing occurs throughout the full voltage period, including during charging, discharging, and idle states.

6.3. Adjustable Operating Modes

The balancer features adjustable operating modes to suit different requirements:

  • Mode 1 (Auto Sleep): When the battery voltage drops below 3V, the balancer automatically turns off balancing and enters sleep mode to conserve power.
  • Mode 0/2 (Always On): The active balance function remains continuously on and does not enter sleep mode.

Video 1: Demonstration of the active balancer in operation, showing current measurement during balancing.

7. Maintenance

  • Keep the balancer clean and free from dust and debris.
  • Ensure the device is kept in a dry environment to prevent moisture damage.
  • Regularly inspect all connections for tightness and signs of wear.
  • Avoid physical impact or dropping the unit.

8. Troubleshooting

  • Device not working / Damaged: Check all wiring carefully. Incorrect polarity or reversed connection order will cause immediate damage.
  • Poor Balancing Performance: Ensure all cable connections are secure. Frequent plugging and unplugging can lead to poor contact. Verify that the balancer is fixed securely to the battery pack.
  • Balancer Overheating / Damage: Avoid creating a voltage difference greater than 0.7V and sustaining it for 10 minutes or longer, as this can damage the balancer. While the maximum current is 10A, prolonged operation at this level is not recommended; a 4A balance current is generally the safest for continuous operation.

9. User Tips

  • Enhanced Battery Performance: Using this active balancer can significantly improve your battery pack's overall performance, extend its lifespan, and enhance safety by preventing cell overcharge/discharge.
  • Dedicated Use: This balancer is designed to be permanently fixed to a single battery pack. Do not attempt to remove and reuse it on different battery packs, as this will likely damage the unit.
  • Solar Energy Storage: When used with solar energy storage batteries, the balance current might appear lower. This is because solar batteries are constantly charging and discharging, leading to smaller voltage differences between cells. The balancer's current output is proportional to the voltage difference.
  • New Battery Packs: For newly assembled battery packs, ensure cell capacities are consistent. While initial voltage differences might not be large, they can increase during full charge/discharge cycles (e.g., 0.2V-0.5V), at which point the balancer will operate with higher current.

10. Frequently Asked Questions (FAQ)

Q: What are the benefits of using this active balancer?
A: It improves battery performance, extends battery life, and enhances safety by maintaining cell voltage equilibrium.
Q: How is this tool classified?
A: It is classified as an active balancer tool, typically used for electrical DIY supplies and battery management systems.
Q: What are the main highlights of this product?
A: Its key highlights include its active balancing feature, high efficiency (96%), and broad compatibility with Li-ion and LiFePO4 batteries across a wide range of cell counts (4S-24S).