1. Introduction
The Dooya DC510 is a 433MHZ wireless vibration sensor designed to detect vibrations and send signals to compatible Dooya emitters, typically used for automated awning and shutter systems. This manual provides essential information for the safe and effective installation, operation, and maintenance of your DC510 sensor.
2. Safety Information
- Read all instructions carefully before installation and use.
- Keep the device away from water and high humidity environments.
- Do not attempt to disassemble or repair the device yourself. Refer to qualified personnel for service.
- Ensure correct battery polarity when installing batteries.
- Dispose of used batteries according to local regulations.
3. Package Contents
- Dooya DC510 Wireless Vibration Sensor
- Batteries (2 x AAA)
- Mounting hardware (screws, anchors)
- Instruction Manual (this document)
4. Specifications
| Feature | Specification |
|---|---|
| Model Number | DC510 |
| Type | Shutters |
| Opening Pattern | Horizontal |
| Certification | CE |
| Origin | Mainland China |
| Color | White |
| Dimensions (L x W x H) | 15cm x 4.1cm x 2.6cm |
| Transmitting Frequency | 433.92MHz |
| Operating Voltage | 3V (2 x AAA batteries) |
| Operating Temperature | -10°C to +55°C |
| Protection Level | IP44 |
| Battery | Included |
For visual reference of specifications, please see the images below:


5. Setup and Installation
5.1. Battery Installation
- Carefully open the back cover of the sensor.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Close the back cover securely. The device will emit two buzzer sounds, indicating it has started normal operation.
Note: After initial activation, the sensor will not respond to vibration for the first 10 seconds.
5.2. Mounting Location
The sensor is typically installed on the inner wall of the front awning beam or a similar stable surface for optimal vibration detection.

5.3. Sensitivity Adjustment
The vibration intensity has 10 adjustable levels (0-9). Use a small screwdriver to adjust the coding switch located inside the sensor:
- Level 1: Most sensitive.
- Level 9: Least sensitive.
- Level 0: No induction (sensor is inactive).
Adjust the level according to your specific needs and environmental conditions to prevent false alarms while ensuring reliable detection.
5.4. Coding (Pairing with Emitter)
The coding switch also determines the type of signal sent for pairing:
- When the coding switch is set to 0, pressing a button on the sensor sends a SETUP code.
- When the coding switch is set to 5, pressing a button on the sensor sends an UP code.
- When the coding switch is set to 9, pressing a button on the sensor sends a DOWN code.
Refer to your Dooya emitter's manual for specific pairing instructions, using the appropriate code type from the sensor.
6. Operating Instructions
Once installed and paired, the Dooya DC510 sensor will continuously monitor for vibrations. Upon detecting a vibration:
- The sensor sends a relevant vibration command to the paired Dooya emitter.
- After sending one vibration command, the sensor will enter a 30-second cool-down period during which it will not send further vibration commands, even if additional vibrations are detected. This prevents excessive signaling.
7. Maintenance
7.1. Battery Replacement
When the sensor's performance degrades or the indicator light no longer illuminates, it's time to replace the batteries. Follow the battery installation steps in Section 5.1.
7.2. Cleaning
Wipe the sensor's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the device.
8. Troubleshooting
- Sensor not responding to vibrations:
- Check battery levels and replace if necessary.
- Ensure the back cover is securely closed. If the back cover is not magnetically attached, related functions are invalid.
- Verify the sensitivity setting (Level 0 disables induction). Adjust to a higher sensitivity if needed.
- Confirm the sensor is within range of the Dooya emitter.
- False alarms:
- Reduce the sensitivity setting to a lower level.
- Ensure the mounting surface is stable and not subject to minor, non-critical vibrations.
- Sensor not pairing with emitter:
- Ensure the coding switch is set to the correct position (0, 5, or 9) as required by your emitter's pairing process.
- Follow the specific pairing instructions for your Dooya emitter model.
9. User Tips
- This sensor is designed to be broadly compatible with various Dooya emitters, including popular models like DC90 and DC1600. Always refer to your specific emitter's manual for detailed compatibility and pairing instructions.
- Experiment with different sensitivity levels to find the optimal setting for your environment, balancing between detecting actual events and avoiding nuisance alarms.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original seller or authorized Dooya distributor. Keep your purchase receipt as proof of purchase.