1. Product Overview

The ZJIVNV SC series UPS charge function switching power supply is designed to provide stable power to your devices while also charging a backup battery. In the event of an AC power failure, the unit automatically switches to battery power, ensuring uninterrupted operation for connected loads.

Various ZJIVNV SC series UPS power supplies
Figure 1: Overview of ZJIVNV SC series UPS power supplies (SC-35W, SC-60W, SC-120W, SC-180W).

This power supply is suitable for a wide range of applications, including automated industry, electric equipment, scientific research equipment, LED lighting, monitoring equipment, and medical equipment.

Diagram showing various applications for the power supply
Figure 2: Applicable scenarios for the SC series power supply.

2. Safety Information

Please read and understand all safety instructions before installation and operation to prevent injury or damage to the device.

  • Ensure proper grounding of the earth wire (surface area of grounded copper wire should exceed 0.75mm).
  • Verify correct input and output line connections (live wire, neutral wire, earth wire for AC; positive pole, negative pole for DC).
  • Do not install screws so long that they touch the circuit board components.
  • Before powering on, ensure the input voltage switch (110V/220V) is set correctly to avoid damage.
  • Avoid frequent on/off cycling of the input voltage, as this can affect the product's lifespan.
  • If the supply voltage fluctuates dramatically, consider installing a power stabilizer or input over/under voltage protector.
  • For large electrical equipment, consider installing an AC filter before supplying voltage.

3. Setup and Wiring

Before connecting, ensure the power supply is disconnected from all power sources. Remove any external plastic packaging before installation.

3.1 Wiring Terminals

The power supply features clearly marked terminals for AC input, DC output, and battery connections.

  • AC Input: 'L' (live wire), 'N' (neutral wire), and earth wire symbol.
  • DC Output: '+V' (positive pole), '-V' (negative pole). For multi-output models, these may be marked as '+V1', '-V1', etc., or directly with voltage values. 'COM' is the common interface for multiplex outputs.
  • Battery Connection: Dedicated terminals for battery charging and backup power.
Schematic diagram of wiring port for 35W, 60W, 120W, 180W models
Figure 3: Wiring diagram for 35W, 60W, 120W, and 180W models. Includes input neutral line, live line, ground wire, output negative pole, output positive pole, charge wire, indicate status, potentiometer (adjustable), and cold start.
Wiring diagram for 350W model
Figure 4: Wiring diagram for the 350W model. Includes output 13.8/12.6V+, output 13.8/12.6V-, input ground, AC input 110/220V, indicator, AC input power off sign terminals, battery power low alarm switch, connect battery +, and connect battery -.

3.2 Input Voltage Selection

Ensure the 110V/220V switch on the unit is set to match your local AC input voltage before connecting to power. Incorrect selection can cause damage.

Top view of power supply showing 110V/220V switch and indicator lights
Figure 5: Input voltage selection switch (110V/220V) and working status indicators.

4. Operating Instructions

The SC series power supply operates with an integrated UPS function, providing continuous power and battery charging capabilities.

4.1 Normal Operation (AC Power On)

When AC power is supplied, the power supply's DC Output CH1 provides power to your connected load devices. Simultaneously, CH2 output charges the connected battery.

4.2 UPS Function (AC Power Failure)

If AC power fails, the unit automatically switches to the backup battery to provide uninterrupted power. This ensures that connected devices do not freeze, restart, or lose data. The switch-over is seamless, requiring no human intervention.

Video 1: Demonstration of the UPS function, showing automatic switch to battery power when AC is turned off.

4.3 Battery Charging and Protection

The power supply features advanced battery management:

  • Over-charging Prevention: Prevents long-term online floating charge to the battery, effectively extending battery life.
  • High Charging Efficiency: Ensures the battery can saturate to over 90%.
  • Auto-stop Charging: Charging automatically stops when the battery is full to prevent overcharging.
  • Low Voltage Discharge Protection: When the battery discharges and its voltage drops below 10.5V (for 12V systems), the power supply stops drawing power from the battery to protect it from deep discharge.
Diagram illustrating UPS functions
Figure 6: Key functions of the UPS: automatic switch between mains and battery, prevention of over-charging, constant float charge, and cold start capability.

5. Maintenance

To ensure optimal performance and longevity of your power supply, consider the following maintenance points:

  • Environmental Conditions: Operate the SMPS in a well-ventilated area. High temperatures (above 40°C) can reduce output power; for example, at 70°C, output power should not exceed 50% of the rated value. Extremely low temperatures (below -10°C) may prevent the power supply from starting or operating normally.
  • Heat Dissipation: The unit features a hollow-out design for efficient heat dissipation. Ensure adequate airflow around the unit.
  • Component Integrity: The power supply is built with high-quality components, including pure copper transformers, high-quality capacitors, and pure copper coils, for stable performance.
Image highlighting the hollow-out design for efficient heat dissipation
Figure 7: Hollow-out design for efficient heat dissipation.
Image showing internal components like pure copper transformer, capacitors, and coil
Figure 8: Excellent electronic components for stable performance.

6. Troubleshooting

This section provides guidance for common issues. For complex problems, consult a qualified technician.

  • No Output Power:
    • Check AC input connections (L, N, Earth).
    • Verify the 110V/220V switch setting matches your local voltage.
    • Ensure the input electric wire cross-section is sufficient (AC voltage reduction not exceeding 5%, DC voltage not exceeding 0.5%).
    • Check for good contact at all screw terminals and switching devices.
  • Battery Not Charging / Incorrect Output:
    • Ensure the battery type selected (for 350W models) matches the connected battery (Lead-acid or Lithium).
    • Verify battery connections are correct (+V, -V).
  • Device Freezes/Restarts during AC Power Failure:
    • This should not happen with the UPS function. Double-check all wiring, especially battery connections and load connections, to ensure they are correctly configured for UPS operation.
  • Power Supply Not Starting in Cold Conditions:
    • Ensure the operating environment temperature is within the specified range (above -10°C).

6.1 Protection Features

The unit includes multiple protections to safeguard your devices:

  • Short circuit protection
  • Overload protection
  • Overvoltage protection
  • Overcurrent protection
Image showing multiple protection features
Figure 9: Multiple protections for device safety.

7. Specifications

The ZJIVNV SC series power supplies come in various wattage options with corresponding output characteristics. Below are general specifications and a detailed table for different models.

7.1 General Specifications

  • Type: Power Supply
  • EU LVD Voltage: Low voltage: Below 50Vac or 75Vdc
  • Rated Capacity: 40-1000VA (includes 40VA)
  • Output Type: SINGLE
  • Output Frequency: 50/60 HZ
  • Certification: CE, FCC
  • Origin: Mainland China
  • Product Size: 215*115*50mm (for 350W model)
  • Warranty: 1 year

7.2 Model-Specific Parameters

Product dimensions for various SC series models
Figure 10: Dimensions for SC-35W, SC-60W, SC-120W, SC-180W, and SC-350W models.
Table of product parameters for various SC series models
Figure 11: Detailed product parameters including input voltage, output channels (CH1, CH2), output voltage, and current for different wattage models (35W, 60W, 120W, 180W, 350W).
Table 1: Model-Specific Output Parameters
ModelInput (VAC)CH1 Output (Load)CH2 Output (Battery Charge)
SC-35-12100-24013.8V 0.2A13.4V 0.5A
SC-35-24100-24027.6V 1A26.5V 0.3A
SC-60-12100-24013.8V 4A13.4V 0.35A
SC-60-24100-24027.6V 2A26.5V 0.25A
SC-120-12110/22013.8V 8A13.4V 0.5A
SC-120-24110/22027.6V 4A26.5V 0.3A
SC-180-12110/22012V 13.5A13.8V 1.5A
SC-180-24110/22024V 7.5A27.6V 1A
SC-350-12 (Lead-acid)110/22012V 30A13.8V 1.5A
SC-350-12 (Lithium)110/22012V 30A12.6V 1.5A
SC-350-24 (Lead-acid)110/22024V 15A27.6V 1.5A
SC-350-24 (Lithium)110/22024V 15A25.2V 1.5A

8. User Tips

  • Seamless Power Transition: Users have reported that the power supply provides stable operation during the switch from mains to battery power, making it ideal for sensitive equipment like industrial computers.
  • Battery Compatibility: For 350W models, ensure you select the correct power supply variant for your battery type (Lead-acid or Lithium) during purchase. This ensures proper charging and protection.
  • Check All Connections: Before initial power-up, double-check all wiring, especially the input voltage switch, to prevent damage and ensure correct functionality.

9. Warranty and Support

The ZJIVNV SC series power supply comes with a 1-year warranty.

For further detailed instructions or technical support, please refer to the official user manual PDF. A comprehensive PDF version of this manual is available for download: