Mindray 115-037544-00

Mindray 115-037544-00 Reaction Cuvette User Manual

For Mindray BS240 and BS-240 Clinical Chemistry Analyzers

1. Product Overview

The Mindray 115-037544-00 Reaction Cuvette is an original, new consumable designed for use with Mindray BS240 and BS-240 clinical chemistry analyzers. These plastic cuvettes are essential components for accurate photometric measurements during in-vitro diagnostic testing.

Mindray 115-037544-00 Reaction Cuvette packaging with individual cuvettes

Figure 1: Packaging of Mindray 115-037544-00 Field Repairable Unit, showing plastic cuvettes (8pcs) in sealed bags.

2. Setup and Installation

Proper handling and installation of reaction cuvettes are crucial for maintaining the integrity of samples and accuracy of results.

2.1 Unpacking

  • Carefully open the product packaging (P/N: 115-037544-00).
  • Verify that the contents match the product description: plastic reaction cuvettes (8pcs).
  • Inspect cuvettes for any visible damage or contamination before use. Do not use damaged cuvettes.

2.2 Loading into Analyzer

Refer to your Mindray BS240 or BS-240 analyzer's specific user manual for detailed instructions on loading reaction cuvettes. General steps include:

  1. Ensure the analyzer is in a safe state (e.g., paused or in standby mode).
  2. Locate the cuvette loading area on your Mindray BS240/BS-240 analyzer.
  3. Carefully remove individual cuvettes from their protective packaging, avoiding contact with the optical surfaces.
  4. Load the cuvettes into the designated positions on the analyzer's reaction tray or rotor, following the analyzer's specific orientation and quantity requirements.
  5. Close the analyzer's cover securely.

Caution: Always handle cuvettes with clean gloves to prevent contamination from skin oils or dust, which can interfere with optical measurements.

3. Operating Principles

The reaction cuvettes serve as the vessels where chemical reactions occur and are subsequently measured by the Mindray BS240/BS-240 analyzer's photometric system.

  • Reaction Chamber: Each cuvette provides a precise, optically clear chamber for the mixing of reagents and patient samples.
  • Photometric Measurement: The analyzer passes light through the cuvette, and the change in light absorption or transmission is measured to determine the concentration of analytes.
  • Single-Use: These cuvettes are designed for single-use only to prevent cross-contamination and ensure accurate results. Do not attempt to clean and reuse cuvettes.

4. Maintenance and Storage

While cuvettes are consumables, proper storage and disposal are essential.

4.1 Storage

  • Store cuvettes in their original, unopened packaging in a clean, dry environment.
  • Keep away from direct sunlight, extreme temperatures, and high humidity.
  • Recommended storage temperature: Room temperature (15-30°C).
  • Avoid storing near strong magnetic fields or sources of vibration.

4.2 Disposal

  • Used cuvettes may contain biohazardous materials. Dispose of them according to your laboratory's biohazard waste disposal protocols and local regulations.
  • Never dispose of used cuvettes in general waste.

5. Troubleshooting

If you encounter issues related to cuvette performance, consider the following:

SymptomPossible CauseSolution
Inaccurate or inconsistent resultsDamaged or scratched cuvette; Contaminated cuvette (dust, fingerprints); Improperly seated cuvette; Expired cuvette.Replace with a new, undamaged cuvette. Ensure proper handling with gloves. Re-seat the cuvette correctly. Check manufacturing date.
Error message related to cuvette loadingCuvette not loaded correctly; Cuvette jammed in mechanism.Refer to analyzer manual for loading procedure. Carefully remove and re-load cuvettes. If jammed, power off analyzer and carefully clear obstruction, then restart.
Visible debris or bubbles in cuvetteContamination during handling; Improper reagent/sample dispensing.Discard and use a new cuvette. Ensure proper pipetting techniques. Check analyzer's dispensing system.

Important: For any persistent issues or analyzer-specific errors, consult the Mindray BS240/BS-240 analyzer's user manual or contact Mindray technical support.

6. Specifications

FeatureDetail
Part NameReaction Cuvette (Field Repairable Unit)
Part Number (P/N)115-037544-00
CompatibilityMindray BS240, Mindray BS-240 Clinical Chemistry Analyzers
MaterialABS (Base Material)
High-concerned chemicalNone
OriginMainland China
Package Dimensions (approx.)Length: 18 cm, Width: 12 cm, Height: 15 cm
Package Weight (approx.)0.25 kg

7. Warranty and Support

This product is an original Mindray part. For specific warranty information regarding consumables, please refer to Mindray's official warranty policy or contact your authorized Mindray distributor.

For technical assistance or inquiries regarding the Mindray 115-037544-00 Reaction Cuvette, please contact:

  • Mindray Customer Service: Refer to your local Mindray representative or the official Mindray website for contact details.
  • Seller Support: For purchase-related queries, you may contact MENGETOO Trading Store.

8. User Tips

  • Handle with Care: Always use clean, powder-free gloves when handling cuvettes to avoid fingerprints or contamination that can affect optical readings.
  • Check Expiry Dates: Although not explicitly stated, consumables often have manufacturing or expiry dates. Ensure you are using fresh cuvettes for optimal performance.
  • Environmental Control: Store cuvettes in a controlled environment as recommended to prevent material degradation or static charge buildup.
  • Analyzer Manual: Always consult your Mindray BS240/BS-240 analyzer's comprehensive user manual for specific instructions on cuvette loading, calibration, and maintenance procedures.

Related Documents - 115-037544-00

Preview NINYIU Water Filter Instruction Manual
Instruction manual for the NINYIU Water Filter, model BS240/BS360E/BS120/2900/DH36. Provides product information, specifications, safety precautions, and customer support details for use with biochemical analyzers.
Preview Mindray DPM 4 Patient Monitor Service Manual
This Mindray DPM 4 Patient Monitor Service Manual provides detailed technical information for qualified personnel. It covers principles of operation, hardware and software descriptions, disassembly, troubleshooting, product specifications, and maintenance for this multi-parameter medical device used in healthcare institutions.
Preview BC-20s Auto Hematology Analyzer Operator's Manual
Operator's Manual for the BC-20s Auto Hematology Analyzer, providing comprehensive guidance on operation, maintenance, and troubleshooting for clinical laboratory professionals.
Preview HyBase RFID Module-3 User Manual | Mindray
Official user manual for the Mindray HyBase RFID Module-3, providing detailed information on intended use, specifications, operation, safety, and compliance.
Preview Vue d'ensemble des commandes de WC Geberit à déclenchement électronique sans contact
Présentation de la gamme Geberit de commandes de chasse d'eau pour WC à déclenchement électronique et sans contact, incluant les modèles Sigma80, Sigma10 et Type 10. Détails sur les caractéristiques, l'alimentation, la compatibilité avec les réservoirs et les accessoires d'installation.
Preview Starrsed RS - Instructions for Use
This document provides instructions for use for the Starrsed RS, an automated analyzer for in vitro determination of the Erythrocyte Sedimentation Rate (ESR) of human blood samples. It details instrument overview, installation, operation, maintenance, and troubleshooting for medical laboratory professionals.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.