1. Product Overview
The AISET NGE-5000 series is a range of high-precision temperature control modules designed for various industrial and electrical applications. These modules feature a clear digital display for process value (PV) and set value (SV), along with intuitive controls for easy operation.

1.1 Key Features
- Digital display for Process Value (PV) and Set Value (SV)
- Indicators for Auto-tuning (AT), Output (OUT), and Alarm (ALM)
- User-friendly control buttons
- High accuracy for precise temperature control
- Compact design for easy integration
2. Specifications
| Parameter | Description |
|---|---|
| Model Number | NGE-5000, NGE-5411V-1, NGE-5411-1, etc. |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Temperature Range | 0-400°C (K type thermocouple) |
| Accuracy | 0.5 level |
| Power Supply | 100-240VAC / 50Hz, 5VA |
| Dimensions (W x H x D) | 72mm x 72mm x 68mm |
| Package Weight | Approx. 0.3 kg |
| Package Dimensions (L x W x H) | 10cm x 8cm x 8cm |


3. Setup and Installation
3.1 Mounting
The NGE-5000 series module is designed for panel mounting. Ensure adequate space for ventilation and wiring connections. Refer to the dimensional drawing in Section 2 for precise cutout and mounting dimensions.
3.2 Wiring Connections
WARNING: Ensure all power is disconnected before performing any wiring to prevent electric shock or damage to the device.
Refer to the wiring diagram below for proper connections. Use appropriate gauge wires for power and output connections.

- Power Supply (100-240VAC): Connect the main power supply to terminals 1 and 2.
- Output (OUT): Connect your controlled device (e.g., heater, relay) to terminals 3 and 4.
- Thermocouple Input (TC): Connect your K-type thermocouple to terminals 5 and 6. Ensure correct polarity (+ to + and - to -) for accurate readings.
- Alarm Output (ALM): If using the alarm function, connect your alarm device to terminals 8 and 9.
4. Operating Instructions
4.1 Front Panel Controls and Indicators
- PV Display (Red): Shows the current Process Value (measured temperature).
- SV Display (Green): Shows the Set Value (target temperature).
- AT Indicator: Illuminates when the auto-tuning function is active.
- OUT Indicator: Illuminates when the control output is active.
- ALM Indicator: Illuminates when an alarm condition is met.
- Power/Set Button (⌛): Used to power on/off (if applicable) and to enter/exit parameter setting modes.
- Down Button (⌄): Used to decrease values or navigate menus.
- Up Button (⌃): Used to increase values or navigate menus.
4.2 Setting the Target Temperature (SV)
- Press the Power/Set button briefly to enter the SV setting mode. The SV display will flash.
- Use the Up (⌃) and Down (⌄) buttons to adjust the Set Value to your desired temperature.
- Press the Power/Set button again to confirm the setting and exit the SV setting mode.
4.3 Auto-Tuning (AT)
Auto-tuning helps the controller optimize its PID parameters for stable temperature control. Consult the full product manual for detailed auto-tuning procedures, as this may vary slightly between specific NGE-5000 models.
5. Maintenance
The AISET NGE-5000 series temperature module is designed for reliable operation with minimal maintenance. Follow these guidelines:
- Cleaning: Keep the front panel clean and free from dust. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Environmental Conditions: Ensure the module operates within its specified environmental conditions (temperature, humidity) to prevent damage.
- Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.
- Calibration: If temperature readings appear inaccurate, professional calibration may be required.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/Power off | No power supply or incorrect wiring. | Check power connections (terminals 1-2) and ensure power is supplied. |
| Inaccurate temperature reading | Incorrect thermocouple type, faulty thermocouple, or incorrect wiring polarity. | Verify thermocouple type (K-type), check thermocouple for damage, ensure correct polarity at terminals 5-6. |
| Output not activating | SV not reached, OUT indicator off, or faulty output wiring. | Check if PV has reached SV. Verify OUT indicator. Inspect wiring to controlled device (terminals 3-4). |
| ALM indicator always on/off | Alarm parameters incorrectly set or faulty alarm wiring. | Review alarm settings. Check wiring to alarm device (terminals 8-9). |
7. User Tips
- Always ensure the correct thermocouple type (K-type) is used with this module for accurate temperature measurement.
- For optimal control performance, consider performing an auto-tune cycle after initial installation or if the controlled process changes significantly.
- Keep the module away from strong electromagnetic interference to prevent erratic readings.