1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the VOTOL EM100 BLDC Controller and the N1S LCD Speedometer. This system is designed for electric drive applications, offering precise control and clear display of vehicle parameters.
The EM100 controller is a sine wave controller with a rated DC current of 60A, a boost DC current of 120A, and a peak phase current of 300A, capable of handling up to 7200W peak power. It is compatible with 48V-72V battery systems and supports PC programmability. The N1S LCD Speedometer provides essential vehicle data, including speed, voltage, battery level, trip distance, and various lighting indicators.
2. Safety Information
WARNING: This product is intended for use by specialists only. Non-specialist use is strictly forbidden.
For the IV generation of EM series controller program updates and parameter adjustment, operations must only be performed by professional and technical personnel. Unauthorized modification or parameter adjustment without written permission from VOTOL is not allowed. The company will not be responsible for accidents resulting from unauthorized or non-professional operation of this software or hardware.
Always read this manual carefully before starting any operation.
3. Package Contents
- 1 x VOTOL EM100 Controller with USB cable
- 1 x N1S LCD Speedometer Display

4. Specifications
4.1 EM100 Controller Specifications
| Feature | Specification |
|---|---|
| Model | EM-100 ECU Sine Wave Controller |
| Available Battery Voltage | 48V-72V |
| Rated DC Current | 60A |
| Boost DC Current | 120A |
| Peak Phase Current | 300A |
| Max. Power | 7200W |
| Mosfets Detail | 18 FET |
| Matched Motor Rated Power | 2KW-3KW |
| Max. Efficiency | 93% |
| Degree of Waterproof | IP67 |
| Flux Weakening Ratio | 150% |
| Certification | CE, CCC |
| Working Communication | Hall Sensor |
| Net Weight | 1650g |
| Size (L x W x H) | 218.36mm x 123.62mm x 51.3mm |
| Material | Aluminum Plastic |
| Design | Programmable sine wave |
| Programmability | Supported via PC |

4.2 N1S LCD Speedometer Specifications
- Speed Sensor Type: One-LIN
- Speed Unit: KMH and MPH switchable
- Voltage Compatibility: 48V, 60V, 72V, 84V, 96V Li-ion battery
- Shell Size: 21cm x 11cm x 9cm
- Displayed Data: Speed (Max 188kmh), Voltage, Battery Level, Trip distance, Head lighting, Gear, Fault Display, Turning lighting.

5. Setup
5.1 USB Driver Installation (Windows 7/10)
- Download the "USB-to-serial-win 10-20150814" file and decompress it.
- Choose the suitable driver for your computer (win7, win10 are supported; iOS and XP are not). If Chinese words appear in the file name for abroad PC systems, please remove them.
- After installation, connect the USB cable from the controller to your computer. If connection issues occur, follow these steps:
- Right-click "My Computer" on the desktop, then select "Manage" > "Device Manager".
- Expand "Ports (COM & LPT)".
- Locate the COM port with an exclamation mark (!), right-click it, and select "Update driver software".
- Choose "Browse my computer for driver software" and navigate to the extracted driver files.
- Select "Prolific USB-to-Serial Comm Port Version: 3.3.2.102 [2008/9/24]" or the latest compatible version.
- Click "Next" to install and then "Close" when finished.
5.2 Software Installation
For versions from 2018.7 onwards, only USB driver installation is required before opening the software directly. For older versions:
- Copy the `TeeChart5.ocx` file to the C drive root directory.
- Click the setup to register the file and complete the installation. Allow the installation if the software shows an intercept interface.
- After installation, run the `EM_V3` program.
5.3 Controller Connection
- Power on the controller, ensuring the ignition is closed.
- If your controller supports CAN, click "CAN enable" and then "Open".
- Click the "researching" button, then select the correct serial port from the device COM list (usually the last one).
- Click "open series port"; the device status should show "connected".
- Turn on the ignition, then click "connect" (it is recommended to click it more than once).
5.4 Wiring Diagrams
Proper wiring is crucial for the correct and safe operation of the controller and speedometer. Refer to the diagrams below for connection details.




5.5 N1S LCD Speedometer Wiring
- Red: Positive 48V-96V +
- Black/Green: Negative GND -
- Purple: ONE-LIN Speed Sensor
- Dark Blue: Head Light
- Orange: Left Light
- Light Blue: Right Light
- Black Plug 1: KMH/MPH Switching
- Black Plug 2: Voltage Switching (Default 72V/60V switching, other voltages can be specified during order)
6. Operating Instructions
The controller software interface is divided into several pages: PAGE1, PAGE2, PAGE3, Display, and Port Settings. Each page allows for specific parameter adjustments and monitoring.
6.1 Battery Voltage Adjustment
The voltage parameter can be freely chosen within the hardware support limits of the controller. Adjustments are made on PAGE1 under Basic Settings. Note: If the voltage parameter is adjusted without hardware support, the controller will be damaged.
6.2 Under-voltage and Soft Under-voltage Adjustment
These parameters protect the battery and controller. Adjustments are made on PAGE1.
- Overvoltage(V): Set the threshold for hardware under-voltage protection based on the battery's under-voltage value.
- Undervoltage(V): Generally set to the under-voltage value + 3V.
- Soft undervoltage(V): The range of under-voltage recovery difference (unadjustable). For example, if set to 63V for overvoltage and 1V for undervoltage variation, the controller will recover at 64V.
Warning: Do not change under-voltage settings excessively, as it can damage the battery and reduce its lifespan due to excessive discharge.
6.3 Current Limit Adjustment
Adjustments are made on PAGE1 for Busbar current and Phase current.
- Busbar Current (A): Limits the battery current. Refer to the table below for setting ranges.
- Phase Current: Limits the motor torque output. The biggest value is full power output; adjustment is generally not suggested.
| Controller Model | Voltage | Max Current |
|---|---|---|
| EM-30S | 48-60V | ≤35A |
| 72V | ≤35A | |
| EM-50 | 48-60V | ≤50A |
| 72V | ≤50A | |
| 96V | ≤45A | |
| EM-100 | 48-60V | ≤100A |
| 72V | ≤100A | |
| 96V | ≤100A | |
| EM-150 | 48-60V | ≤150A |
| 72V | ≤180A | |
| 96V | ≤120A |
Warning: Do not fill in values outside the specified range, as it will damage the controller. For dual voltage mode, the flux weakening range depends on the voltage (low voltage on the left, high voltage on the right). For single voltage controllers, keep left/right values the same.
6.4 Throttle Voltage Adjustment
Adjustments are made on PAGE1 under "throttle voltage set (max. 5.5v)".
- Low Protect: Indicates throttle error.
- Start Voltage: Motor starts running when this value is reached.
- End Voltage: Controller considers full voltage reached. Recommended to set 0.2V lower than actual torque voltage.
- High Protect: If the value is higher than this, a torque fault will be displayed.
6.5 Start Setting Adjustment (for tricycle gearbox only)
Adjustments are made on PAGE1 under "start setting".
- Start Torque: Used for gear combination.
- Combinative Torque: Force of lifting after gear clearance.
- Rate of Rise (Upward Slope): Upward slope of motor torque.
- Rate of Decline (Downward Slope): Downward slope of motor torque.
6.6 Controller and Motor Temperature Protection
Adjustments are made on PAGE1 under "External temp protection setting(°C)".
- Start: Temperature at which protection function activates, limiting motor torque.
- Over Temp: Temperature at which motor torque output is cut off.
- Recovery: When motor temperature drops below this value, re-twisting the throttle restores motor power.
- Max: Maximum motor temperature is 150°C.
6.7 Sport Mode Settings (S Gear)
Adjustments are made on PAGE2 under "Sport mode setup".
- Current-Limiting (A): Increases battery current for more powerful climbing.
- Flux-Weakening Value: Adjusts for motor running noise and shock. If the motor has shock, set this data lower than 800. It will not reduce speed.
- Automatic Logout Enablers: If selected, the system automatically exits sport mode after a set time.
- Logout Time (S): Time after which sport mode is exited (e.g., 30s).
- Recovery Time (S): Time to recover from sport mode.
Warning: The yellow mark indicates Capacitor protection value; modification is not recommended. The red mark indicates flux weakening value, which can be adjusted by motor. Mid Flux-weakening value is for motor start speed. Setting values out of range can cause motor demagnetization and damage.
6.8 Downhill Electric Brake Assist (HDC/HHC)
Adjustments are made on PAGE2 under "Downhill electric brake assist". This function helps maintain constant speed on steep slopes.
- HHC Enable: Enables the function to stabilize RPM.
- HDC Lowrst Speed: Set this value to keep maximum speed consistent, especially with lower battery voltage. For a motor with 1000rpm, you can set this from 1000rpm to 1200rpm. Do not set this value much higher than the motor's actual RPM (e.g., real RPM *110%~120%).
6.9 Speed Limit Setting
Adjustments are made on PAGE2 under "Speed limit setting".
- Speed Limited Enable: Activates the speed limit function.
- Speed Ratio (%): Adjustable controller speed limit from 0 to 100 percent. Can be customized via a sport wire to the speed limit function.
6.10 Flux Weakening & Three Speed Setting
Adjustments are made on PAGE2.
- Flux Weakening Compensation: Factor (generally not recommended to change). Default values are 34 for hub motors less than 40mm magnet and 64 for other motors.
- Three-speed (Low%, Mid%, Hige%): Sets the three-gear ratio range from 0-100%.
- Mid Flux-Weakening Value: Data for motor start speed (range 2000-6000). If flux weakening is not desired, set to 200-500.
- Hige Flux-Weakening Value: Additional flux weakening data.
- Button/Switch 3 Speed: Selects between button or switch control for three speeds.
- Soft Start Enable: Enables soft start. Soft start grade (1-16) determines the softness (lower value = softer start).
6.11 Motor Settings
Adjustments are made on PAGE3 under "Motor Setting".
- Pole Pairs: Correctly fill in for accurate motor speed (RPM) acquisition.
- Motor Type: Correctly fill in the motor's magnet type for proper motor matching. Wheel hub motors are surface mount; QS can set 120 hall shift for V3 motors.
- Hall Shift Angle: Adjusts the hall phase shift angle (-180 to 180 degrees). You can test values like -180, -120, -60, 0, 60, 120, 180. To change running direction, add or subtract 120 from your current data.
6.12 Speedometer Output
Adjustments are made on PAGE3 under "Out-put". The controller offers two types of speedometer data output: ONE-LIN speedometer and hall speedometer. The choice depends on the vehicle's speedometer type. ONE-LIN communication uses a fixed agreement (xinsiwei agreement).
6.13 Moving Assist and Cruising Function
Adjustments are made on PAGE3.
- Moving Vehicle Booster (Move Assist): Valid after checking. The speed of the transfer assist is a percentage of the motor base speed (default 10%). Moving assist torque value 320 corresponds to 9-10N.m (varies by motor characteristics).
- Cruise Function: Valid after checking. To enter cruise control, maintain a certain throttle angle for more than 8 seconds. Any operation (e.g., braking, turning the handle) will exit cruise mode.
6.14 Dual Voltage Adaptive Function
Adjustments are made on PAGE3. This function allows the controller to automatically switch between low and high voltage modes.
- 48-60V Mode: Switches to high volt mode if voltage is >63.5V.
- 60-72V Mode: Switches to high volt mode if voltage is >77V.
- 72-84V Mode: Switches to high volt mode if voltage is >93.5V.
6.15 Reversing, EBS Setting, Low Brake Selection, Starting Safety Switch Function
Adjustments are made on PAGE3.
- Reversing Speed Limit (%): 0-100 pole adjustment. Do not exceed 30% to avoid accidents.
- EBS Ratio (%): 0-100 pole adjustment for electronic brake force.
- Low Brake Enable: When enabled, the original single-branch power-down function becomes a low-level brake.
- Safety Switch Function: When enabled, the safety switch must be pressed before starting the vehicle.
7. Maintenance
The EM100 controller and N1S speedometer are designed for durability. Regular inspection of wiring connections for wear or damage is recommended. Keep the components clean and free from excessive dust or moisture.
As noted in the safety information, any programming or advanced adjustments to the controller should only be performed by professional and technical personnel to prevent damage and ensure safe operation.
7.1 Controller Test
Each controller and motor is tested before shipment to ensure proper working condition.

8. Troubleshooting
8.1 Software COM Port Not Found
If your computer has COM information but the software doesn't display it, there might be a driver issue. Re-install the driver or try installing the "FT232 Driver".
8.2 Controller Self-Learning Work
The controller performs self-learning for "hall angle shift" data. Other data details can be found in the provided documentation (e.g., `https://www.dropbox.com/sh/k5xur45yds5es0y/AAAtvUGGJ5w5r01p1v9vzexpa?dl=0`).
8.3 Controller Fault or Hall Error
If the controller operates normally on the road but the software shows a controller fault when connected to a PC, it is generally not a problem. However, if the controller cannot run on the road and the software shows a hall error (with hall connected), follow these steps:
- Check the plug connections first.
- If connections are good, test the controller's Hall voltage:
- Connect the positive and negative battery terminals to the controller.
- Turn on the ignition and power on.
- Measure the positive and negative poles of the controller Hall. It should be around 5V. If the reading is different (e.g., 0.9V), the hall port is damaged.
Damage to the hall port is often caused by incorrect wiring of the hall plug or using a motor hall plug with a different color sequence. Always ensure correct positive and negative connections to prevent immediate damage upon power-on.
8.4 Reverse Function Not Working
If the reverse function wire is connected correctly and the display shows 'R' gear, but the motor does not reverse, check your software parameters. Sometimes there might be two ports configured for reverse; remove one to empty to resolve the issue.
8.5 Motor Still Running After Releasing Throttle
If the motor continues to run after releasing the throttle, try adjusting the hall shift data. For example, change from -60 to 120 and test different values. Refer to the 6.11 Motor Settings section for guidance.
8.6 Software Cannot Be Installed
If the software fails to install, try changing your computer's system language to English or Chinese. This issue can occur due to differences in C++ runtime libraries, especially on PCs in certain countries not set to English.
8.7 Controller Cannot Communicate / Brush Bottom Program
If the controller cannot communicate, you can try to re-flash the bottom program (firmware):
- Close the ignition.
- Open the debugging software (upper computer), open the serial port (no need to click "connect").
- Open the ignition, then open the "CAN.Bin" file.
- Click "download". When the progress reaches 100%, the file import is successful.
- Connect normally afterward.
9. User Tips
- Always read the entire manual carefully before attempting any installation or configuration.
- Avoid setting parameter values outside the recommended ranges, especially for current limits and voltage, as this can cause irreversible damage to the controller and battery.
- If you are unfamiliar with electric kit assembly, exercise caution and consider seeking professional assistance. Man-made damage is not covered under warranty.
- For motor running noise or shock, adjusting the Flux-Weakening Value (on PAGE2) to below 800 might help without reducing speed.
- The yellow-marked Capacitor protection value in the software is generally not recommended for modification.
- When setting the reversing speed limit, do not exceed 30% to prevent accidents.
10. Warranty and Support
We offer a 1-year warranty for motors and controllers. Please note that the buyer is responsible for the return shipping cost for repairs or replacements under warranty.
If you encounter any problems or have questions, please do not hesitate to contact us. We are committed to providing assistance and support to ensure your satisfaction.