1. Introduction
This manual provides detailed instructions for the installation, setup, and operation of your QIACHIP 433Mhz Universal Wireless Remote Control Switch (Receiver Model KR3001-4) and its accompanying RF Transmitter (Remote Control Model KT05-4). Please read these instructions carefully before use to ensure proper functionality and safety.
Important Note: All operating modes of this product require the use of the QIACHIP remote control (transmitter) and controller (receiver/wireless remote switch) to achieve. We cannot guarantee that remote controls from other brands will work properly with our products.

2. Specifications
2.1. Receiver (Model: KR3001-4)
| Feature | Specification |
|---|---|
| Model Number | KR3001-4 |
| Input Voltage | DC 5V ~ 60V |
| RF Working Mode | Superheterodyne Reception |
| RF Frequency | 433MHz (433.92MHz) |
| Modulation Mode | ASK |
| Quiescent Current | 5mA |
| Receiving Sensitivity | >97dbm |
| Working Modes | Momentary, Toggle, Latching, Time Delay (5s, 10s, 15s, 20s) |
| Wired Connection Way | Fixed Wiring Pillar |
| Decoding Mode | MCU Software Decoding |
| Working Temperature | -10°C ~ +80°C |
| Size | 35mm x 30mm x 15mm |
2.2. Transmitter (Remote Control Model: KT05-4)
| Feature | Specification |
|---|---|
| Model Number | KT05-4 |
| Operating Frequency | 433MHz |
| Power Source | 3V Coin Cell Button Battery (Included) |
| Material | PVC |
| Buttons | 2 Buttons (A, B) |
| Size | 59mm x 28mm x 8mm |
| Operating Voltage | 3V |
| Operating Current | 12mA |
| Transmitting Power | 10mw |
| Modulation Mode | ASK (AM) |
| Encoding Type | Learning |
| Remote Control Range | 20-50 m (Indoor), >100m (Free Space) |

3. Components Overview
The QIACHIP receiver module features several key components for its operation:

- LED Indicator: Provides visual feedback on the receiver's status, especially during learning and reset procedures.
- Learning Button: Used to program the remote control and set the working mode.
- Antenna: For receiving RF signals from the remote control.
- Terminal Block: For wired connections.
3.1. Terminal Definitions:
- V-: Negative electrode (Power Input)
- V+: Positive electrode (Power Input)
- NO: Normal Open (Relay Output)
- COM: Common terminal (Relay Output)
- NC: Normal Close (Relay Output)

The remote control (transmitter) has two buttons, typically labeled 'A' and 'B', used to send commands to the receiver.
4. Setup and Wiring
Proper wiring is crucial for the safe and correct operation of the device. Ensure the power supply matches the receiver's input voltage range (DC 5V-60V).
4.1. General Wiring Diagram (Load)
This diagram shows how to connect the receiver to a load, such as a light, using a DC 5V-60V power source.

Steps:
- Connect the positive (+) terminal of your DC 5V-60V power supply to the V+ terminal on the receiver.
- Connect the negative (-) terminal of your DC 5V-60V power supply to the V- terminal on the receiver.
- For controlling a light or similar load:
- Connect one side of the load (e.g., light bulb) to the COM (Common) terminal of the receiver.
- Connect the other side of the load to the NO (Normal Open) terminal of the receiver.
- Connect the remaining power line (e.g., negative from power supply) to the other side of the load to complete the circuit.
4.2. Door Lock Switch Wiring Diagram
This diagram illustrates connecting the receiver to an electromagnetic door lock.
Steps:
- Connect the positive (+) terminal of your DC 5V-60V power supply to the V+ terminal on the receiver.
- Connect the negative (-) terminal of your DC 5V-60V power supply to the V- terminal on the receiver.
- For controlling a door lock:
- Connect one terminal of the door lock to the COM (Common) terminal of the receiver.
- Connect the other terminal of the door lock to the NO (Normal Open) terminal of the receiver.
- Ensure the door lock's power requirements are met by the connected power supply.
4.3. External Power Supply Wiring Diagram (Can connect any voltage)
This setup allows the receiver to be powered by DC 5V-60V, while controlling a separate load with a different voltage (e.g., 1V-250V AC/DC).

Steps:
- Connect the positive (+) terminal of your DC 5V-60V power supply to the V+ terminal on the receiver.
- Connect the negative (-) terminal of your DC 5V-60V power supply to the V- terminal on the receiver.
- For controlling a load with an external power supply:
- Connect one line from the external power supply to the COM (Common) terminal of the receiver.
- Connect the other line from the external power supply to one side of your load (e.g., light).
- Connect the other side of your load to the NO (Normal Open) terminal of the receiver.
5. Operation Modes and Learning
The QIACHIP receiver supports several working modes. You can program the remote control to operate in Momentary, Toggle, Latching, or Time Delay modes.
5.1. Settings Reset (Clearing the Code)
To clear all previously learned remote control data from the receiver's memory:
- Press the Learning Button on the receiver 8 times.
- The receiver's LED light will flash, indicating that the reset function is complete and all remote controls are cleared. After clearing, no remote control will be able to operate the receiver until re-learned.
5.2. Learning Momentary Mode
In Momentary mode, the relay connects only while the remote button is pressed and disconnects upon release.
- Press the Learning Button on the receiver once.
- Wait for a moment; the LED on the receiver will light up, indicating it has entered the setting state.
- Press a button on your remote control (e.g., button A) once.
- The LED indicator on the receiver board will flash and then turn off. The Momentary Mode is now successfully set.
5.3. Learning Toggle Mode
In Toggle mode, one press of the remote button connects the relay, and a second press disconnects it.
- Press the Learning Button on the receiver twice.
- Wait for a moment; the LED on the receiver will light up, indicating it has entered the setting state.
- Press a button on your remote control (e.g., button A) once.
- The LED indicator on the receiver board will flash and then turn off. The Toggle Mode is now successfully set.
5.4. Learning Latching Mode
In Latching mode, one remote button connects the relay, and another remote button disconnects it. This mode requires two distinct buttons on the remote control.
- Press the Learning Button on the receiver three times.
- Wait for a moment; the LED on the receiver will light up, indicating it has entered the setting state.
- Press the first button on your remote control (e.g., button A) once. The LED will flash and then light up continuously.
- Then, press the second button on the same remote control (e.g., button B) once. The indicator will flash and then turn off. The Latching Mode is now successfully set (Button A for ON, Button B for OFF).
5.5. Learning Time Delay Mode
In Time Delay mode, the relay connects when the remote button is pressed and released, then automatically disconnects after a set delay time.
- Press the Learning Button on the receiver the required number of times for your desired delay:
- 4 times for a 5-second delay
- 5 times for a 10-second delay
- 6 times for a 15-second delay
- 7 times for a 20-second delay
- Wait for a moment; the LED on the receiver will light up, indicating it has entered the setting state.
- Press a button on your remote control (e.g., button A) once.
- The LED indicator on the receiver board will flash and then turn off. The selected Time Delay Mode is now successfully set.
6. User Tips
- Testing Range: Before final installation, test the remote control range in your intended environment to ensure it meets your needs. Obstacles and interference can reduce the effective range.
- Power Supply: Always ensure your power supply voltage is within the DC 5V-60V range for the receiver. Using an incorrect voltage can damage the device.
- Secure Connections: Double-check all wired connections to the terminal block to prevent loose contacts, which can lead to intermittent operation or electrical hazards.
- Application Versatility: This module is highly versatile. Consider its use for various applications such as controlling garage doors, electric gates, lighting systems, or other low-voltage devices.

7. Maintenance
- Cleaning: Keep the receiver and remote control clean and free from dust and moisture. Use a soft, dry cloth for cleaning.
- Battery Replacement (Remote Control): The remote control is powered by a 3V coin cell button battery. If the remote's indicator light dims or its range decreases, replace the battery.
- Environmental Conditions: Avoid exposing the device to extreme temperatures, direct sunlight, or corrosive environments. The operating temperature range is -10°C to +80°C.
- Firmware: There are no user-serviceable firmware updates for this device.
8. Troubleshooting
If you encounter issues with your QIACHIP remote control switch, try the following steps:
- Remote not responding:
- Check the battery in the remote control. Replace if necessary.
- Ensure the remote is within the effective operating range (20-50m indoors, >100m in free space).
- Verify that the receiver is powered on and its LED indicator is active.
- Receiver not responding:
- Check the power supply to the receiver. Ensure it is within the DC 5V-60V range and properly connected.
- If the receiver's LED is not lighting up, check wiring and power source.
- Try resetting the receiver (Section 5.1) and re-learning the remote control (Sections 5.2-5.5).
- Incorrect operating mode:
- If the relay behaves unexpectedly (e.g., stays on when it should turn off), the operating mode might be incorrectly set. Perform a settings reset (Section 5.1) and re-learn the desired mode.
- Intermittent operation:
- Check all wiring connections for looseness or corrosion.
- Ensure there are no strong RF interference sources nearby.
9. Warranty and Support
For any issues not covered in this manual, please contact the seller or manufacturer for technical support. Keep your purchase receipt as proof of purchase for warranty claims. The manufacturer is committed to providing high-quality products and support.