YIDIAN M-30ES

Contents

YIDIAN M-30ES Magnetic Grid Displacement Digital Display Table

Model: M-30ES | Brand: YIDIAN

1. Product Presentation

The M-30ES Angle automatic tracking measurement table utilizes a high-performance sensor and a complex, meticulous calculus algorithm to automatically track changes in measurement angles. Its key advantages include direct tracking and measurement of the object, high measurement accuracy, simple installation, and no accumulation error. The device can accurately track and measure changed angles even after power-off.

2. Specifications

General Parameters

  • Product Name: M-30ES angle display measuring instrument (integration of display and angle displacement sensor system)
  • Model: M-30ES
  • Brand Name: YIDIAN
  • Origin: Mainland China
  • Certification: NONE
  • Applicable Industries: Woodworking machinery, stone machinery, glass machinery, and other equipment
  • Applicable Machine: Panel Saw
  • Applicable Brands: Nanxing, HODE, etc.
  • Power Supply: 9-24V (DC9V~28V or AC9V~24V)
  • Advantages: Effective protection of the voltage range of the digital display, multi-function menu, free setting of relevant parameters.

Functional Parameters

  • Measurement Range: ± 180°
  • Angle Adjustment Multiple: 0.5 to 2 times (continuously manually or automatically adjustable)
  • Precision: Optional
  • Memory: Power-off automatically saves the current value
  • Panel Buttons: Can be locked for protection against misoperation
  • Angle Direction Setting: Manual or automatic setting for sensor swing direction
  • Anti-Jitter Function: Optional anti-shake lock time and release angle

Structure Dimensions

All dimensions are in millimeters (mm).

Technical drawing showing front, side, and rear dimensions of the M-30ES display unit.
Figure: M-30ES Display Unit Dimensions
  • Front View: 73.7mm (width) x 36.2mm (height)
  • Side View: 32.1mm (depth), 4mm (mounting flange thickness)
  • Rear View: 67.6mm (width)

3. Setup and Installation

Angle Multiple and Direction Automatic Adjustment

The M-30ES features an automatic adjustment function for angle multiple and direction. Consider a scenario where the sensor operates between two edges, with an actual swing range of 30 degrees:

  1. Step 1: If Menu P06 is set to 0, position the sensor at ZERO and press the ZERO button to set the angle to 0°.
  2. Step 2: If Menu P07 is set to 45, press the END button to set the angle to 45°.

In this example, with an actual angle of 30 degrees displaying 0 to 45 (a difference of 45 degrees), the angle adjustment multiple will automatically adjust to 1.5 times (45 / 30 = 1.5), and the direction will be adjusted as required.

Important Setup Considerations:

  • The angle adjustment multiple should remain within the range of 0.5 to 2 times. Exceeding this range will result in an "Err" prompt.
  • If the multiple is within the reasonable range but setting still fails, adjust the physical installation angle of the sensor until successful.
  • If the angle change direction is not as expected (e.g., angle increases from 'first step' to 'second step' but the actual effect is opposite), reinstall the high-speed sensor to correct the angle until the setting is successful.

4. Operation

Key Functions

KeyShort Press (Working State)Long Press (Working State)Short Press (Setting State)Long Press (Setting State)
CLR/ESCClear Angle OffsetExit (not saving parameters)
ZERO ▲Set current position as starting angle (P06 menu value)Value increase / Switch to setting valueNumerical continuum increases
END ▼Set current position as end angle (P07 item menu value)Shift position (to edit each value)
MENU/ENTEREnter System SettingsEnter / Determine (save parameters)

System Settings

To access system settings:

  1. Press the MENU key.
  2. The display will show "00000". Enter the password "11111".
  3. Click the MENU key again to enter the option settings.
  4. Click ESC to cancel the operation.

The following table details the available settings:

ParameterDescription
P00Select the display accuracy (0.5, 0.1, 0.05). Note that at 0.05 precision, the display range is -99.95 to 99.95°.
P01Angle multiple, the measured angle after the value, range: 0.5000 to 2.0000.
P02Select the anti-shake lock release angle (0.0, 0.2, 0.5, 1, 2, 3). After anti-shake lock, only if the shake exceeds this angle will it release. Note that this angle is the actual jitter angle of the sensor (not scaled), while the angle displayed on the interface may be scaled. If 0.0 is selected, the anti-shake function is turned off.
P03Select the time to enter the stabilization state (5 seconds, 10 seconds, 15 seconds). If stable during this period, it enters the stabilization lock state.
P04Adjust the angle direction. When the sensor swings in a certain direction, the angle can be increased or reduced. Can be set to 0 or 1 to indicate different directions.
P05Long key function is on or off in working state. If set to "OFF", the long press function of "CLR", "ZERO" and "END" in working state will fail.
P06Angle value of the starting position. No matter which position of the sensor, pressing ZERO will change the angle value and the angle multiple unchanged. If the current angle multiple is not enough to show the angle value, the angle multiple will be automatically set to the maximum (2 times), and the range is less than 360.0 degrees.
P07The angle value of the end position. No matter where the sensor is in the working position, pressing END will change the angle value and adjust the angle multiple and angle offset to keep the angle value of the starting position unchanged. Range: greater than 0 degrees and less than 360.0 degrees.
P08The start and end Angle stabilization enhancement is on or off. If set to OFF, close the function and set to ON to open the function. When the Angle swings to the beginning or end Angle, the swing or stabilization within a range will be locked to the start Angle or the end Angle.

5. Maintenance

  • Keep the display unit and sensor clean and free from dust and debris.
  • Avoid exposing the device to excessive moisture or extreme temperatures.
  • Regularly check cable connections for any signs of wear or damage.
  • Ensure the battery compartment (if applicable for backup) is clean and batteries are correctly installed.

6. Troubleshooting

Common Issues and Solutions:

  • "Err" Prompt Displayed: This indicates that the angle adjustment multiple is outside the allowed range of 0.5 to 2 times. Adjust the multiple within this range.
  • Setting Failure (Multiple within Range): If the multiple is within the reasonable range but setting still fails, try adjusting the physical installation angle of the sensor until the setting is successful.
  • Unexpected Angle Change Direction: If the angle changes in the opposite direction to what is expected, reinstall the high-speed sensor to correct the angle direction.
  • Unresponsive Keys (Error Message Displayed): When an error message is displayed, the device may not respond to all key presses. Resolve the underlying error first.
  • Anti-shake Function: If the anti-shake function is enabled and the sensor remains stable (jitter within 0.2), it enters a locked state where the displayed angle does not change. This state exits only when there is significant jitter. Adjust the anti-shake lock release angle (P02) and stabilization time (P03) as needed.

7. User Tips

No specific user tips or frequently asked questions were available from the provided data. Always refer to the detailed instructions for optimal performance and safety.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized dealer. Keep your purchase receipt as proof of purchase.

9. Product Media

Product Overview Video

Video: A comprehensive overview of the M-30ES digital display unit, showcasing its design, components, and connections from various angles.

Product Images

Front view of the M-30ES digital display with attached cable.
Front view of the M-30ES digital display with attached cable.
Side view of the M-30ES display unit, showing the battery compartment labeled '1.5V AA/LR6 Alkaline'.
Side view of the M-30ES display unit, showing the battery compartment labeled '1.5V AA/LR6 Alkaline'.
Side view of the M-30ES display unit, showing the model number 'M-30ES' and 'CE' marking.
Side view of the M-30ES display unit, showing the model number 'M-30ES' and 'CE' marking.
Close-up of the M-30ES digital display panel with buttons (CLR/ESC, ZERO, END, MENU/ENTER).
Close-up of the M-30ES digital display panel with buttons (CLR/ESC, ZERO, END, MENU/ENTER).
M-30ES digital display connected to an external sensor/connector unit.
M-30ES digital display connected to an external sensor/connector unit.
M-30ES digital display and external sensor/connector unit from a different angle.
M-30ES digital display and external sensor/connector unit from a different angle.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.