PowMr POW-HVM4.5K-24V / POW-HVM6.5K-48V

Contents

PowMr Hybrid Solar Inverter User Manual

Models: POW-HVM4.5K-24V / POW-HVM6.5K-48V

Pure Sine Wave Inverter with MPPT Solar Battery Charger

1. Introduction

This manual provides essential information for the safe and efficient operation of your PowMr Hybrid Solar Inverter. This advanced all-in-one solar inverter package is designed to provide a reliable and stable power supply for various applications, integrating a solar inverter unit with a user-friendly interface.

The inverter features a unique glass top cover design with a 6.25-inch display and responsive touchscreen buttons for convenient setup and monitoring. It supports a wide photovoltaic input range and includes a powerful MPPT charging module.

2. Key Features

  • Wide PV Input Voltage Range: 55V~450VDC (with battery connected) or 120V~450VDC (without battery) for flexible solar panel configurations.
  • High MPPT Charging Current: Built-in 150A (for 4.5K model) / 130A (for 6.5K model) MPPT solar charger for efficient energy harvesting.
  • Battery Compatibility: Compatible with 24V/48V lithium-ion and lead-acid batteries (AGM, GEL, FLD, SLD, LI, USER types).
  • Lithium Battery Activation: Features built-in automatic activation for lithium batteries.
  • High Output Power: Up to 4500W (4.5K model) / 6500W (6.5K model) with a power factor of 1.0.
  • Efficient Operation: No derating when AC input voltage is greater than 170V. Max solar charging efficiency up to 98%.
  • Low Standby Power: Only 2W standby power consumption.
  • Smart Design: Includes cooling fans for excellent heat dissipation and a dust-proof cover for harsh environments (optional anti-dusk kit available).
  • Comprehensive Protection: Offers over temperature, over voltage, PV over voltage, short circuit, discharge, over charge, over current, under voltage, over-load, and backfill protection.
  • Optional WiFi Monitoring: Can be equipped with a WiFi accessory for remote monitoring.

3. Setup and Installation

Proper installation is crucial for the safe and optimal performance of your inverter. Please follow these guidelines carefully.

3.1 Component Identification

Familiarize yourself with the inverter's components and connection points:

PowMr Hybrid Inverter Component Diagram

Figure 3.1: Inverter Front and Rear Panel Components

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Touch Function buttons (ESC, UP, DOWN, ENTER)
  6. Power ON/OFF switch
  7. AC input
  8. Main output
  9. Second output
  10. PV 1 and PV 2 input
  11. RS232/WIFI/Remote LCD Communication Port
  12. Battery input
  13. Anti dust cover

3.2 Wiring Diagram

The following diagram illustrates a typical PV off-grid system energy storage setup with the hybrid inverter:

PV Off Grid System Energy Storage Expert Wiring Diagram

Figure 3.2: Typical System Wiring Diagram

Ensure all connections are secure and correctly polarized. Consult a qualified electrician for installation if you are unsure.

3.3 Battery Connection

The inverter is compatible with various battery types. When connecting lithium batteries, ensure the battery type is set to 'LI' in the inverter settings. The lithium battery will be activated by solar energy after 3 seconds.

Inverter Compatible Battery Types

Figure 3.3: Compatible Battery Types

4. Operating Instructions

4.1 Powering On/Off

Use the Power ON/OFF switch (component 6 in Figure 3.1) to turn the inverter on or off. Ensure all connections are verified before powering on.

4.2 LCD Display and Controls

The 6.25-inch LCD display provides real-time system status, including input/output voltage, charging status, and fault indicators. Use the touch function buttons (ESC, UP, DOWN, ENTER) to navigate menus and adjust settings.

4.3 Charging and Output Modes

The inverter supports multiple charging and output modes to optimize energy usage:

Multiple Charging and Output Modes Diagram

Figure 4.1: Charging and Output Modes

  • Charging Modes: Solar priority, Solar+Utility, Only solar.
  • Output Modes: Solar priority, Utility priority, SBU mode.

Refer to the inverter's on-screen menu for detailed configuration of these modes.

4.4 Remote Monitoring (Optional)

If equipped with the optional WiFi accessory, you can monitor your inverter remotely. Connect the WiFi accessory to the RS232/WIFI/Remote LCD Communication Port (component 11 in Figure 3.1) and follow the instructions provided with the accessory for setup.

Video 4.1: PowMr Hybrid Inverter Unboxing and Feature Overview

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

5.1 Cleaning

The inverter features a dust-proof cover and cooling fans. Periodically inspect and clean the cooling fans and vents to prevent dust accumulation, which can affect heat dissipation. Use a soft, dry cloth for cleaning the exterior. Do not use liquid cleaners.

Smart Design with Cooling Fans and Dust-proof Cover

Figure 5.1: Cooling Fans and Dust-proof Cover

5.2 Connection Checks

Regularly check all electrical connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion. Loose connections can lead to poor performance or safety hazards.

5.3 Environmental Considerations

Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, moisture, and flammable materials. The operating temperature range is 0℃ to 55℃, and storage temperature is -15℃ to 60℃.

6. Troubleshooting

This section addresses common issues you might encounter with your inverter.

6.1 General Protection Features

The inverter is equipped with comprehensive protection mechanisms. If a fault occurs, the fault indicator (component 4 in Figure 3.1) will illuminate, and an error code may be displayed on the LCD. Refer to the specific error code in the full user manual for detailed troubleshooting steps.

Inverter 360 Degree Protection Features

Figure 6.1: Inverter Protection Features

  • Short Circuit Protection
  • Over Current Protection
  • Over Voltage Protection
  • Under Voltage Protection
  • Over-Load Protection
  • Backfill Protection
  • Over-Temperature Protection
  • Over Charge Protection

6.2 Common Issues & Solutions

  • Inverter not turning on: Check battery connections, DC breaker, and ensure sufficient battery voltage.
  • No AC output: Verify AC output connections, check for overload, and ensure the inverter is in an appropriate operating mode (e.g., Solar priority, Utility priority).
  • Low PV charging: Ensure solar panels are clean, not shaded, and correctly connected. Check PV array MPPT voltage range.
  • Inverter not accepting 110V AC input: This inverter is designed for 230Vac nominal input. It does not support 110V AC input.

7. Specifications

ParameterPOW-HVM4.2M-24V-NPOW-HVM6.2M-48V-N
Line Mode Specifications
Input Voltage WaveformPure Sine Wave (Utility or Generator)
Nominal Input Voltage230Vac
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz/60Hz (Auto detection)
Output Short Circuit ProtectionLine mode: Circuit Breaker; Battery mode: Electronic Circuits
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Inverter Mode Specifications
Rated Output Power4.2KW6.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50HZ
Peak Efficiency0.93
Overload Protection3s@≥150% load; 5s@101%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24Vdc48Vdc
Cold Start Voltage23.0Vdc46.0Vdc
No Load Power Consumption30W50W
Charge Mode Specifications
Charging Algorithm3-Step
AC Charging Current (Max)100A100A
Max. PV Array Power6200W6500W
Nominal PV Voltage240Vdc360Vdc
PV Array MPPT Voltage Range60Vdc~450Vdc (Battery Connected) / 120Vdc~450Vdc (Battery Disconnected)90Vdc~500Vdc (Battery Connected) / 120Vdc~500Vdc (Battery Disconnected)
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)120A120A
Grid-Tie Operation
Nominal Output Voltage220/230/240VAC
Feed-in Grid Voltage Range195-253VAC
Feed-in Grid Frequency Range49-51±1Hz/59-61±1Hz
Nominal Output Current18.2A26.9A
Maximum Conversion Efficiency (DC/AC)97%
Two Load Output Power
Full Load4200W6200W
Maximum Main Load4200W6200W
Maximum Second Load (battery model)1400W2066W
Main Load Cut Off Voltage26VDC52VDC
Main Load Return Voltage27VDC54VDC
General Specifications
Safety CertificationCE
Operating Temperature Range0℃ to 55℃
Storage temperature-15℃ to 60℃
Dimension (D*W*H)468*318*159mm
Net Weight7.5KG/9.5KG (depending on model)

8. User Tips

  • Operation Without Battery: Yes, this inverter can operate without a battery. When operating without a battery, the PV Array MPPT Voltage Range is 120VDC~450VDC (for 4.5K model) or 120VDC~500VDC (for 6.5K model).
  • Battery Compatibility: The inverter is designed to work with a variety of battery types including AGM, GEL, FLD, SLD, LI (Lithium-ion), and USER-defined settings. Ensure you select the correct battery type in the inverter's settings for optimal performance and safety.
  • Anti-Dusk Kit: An optional anti-dusk kit is available for installations in harsh, dusty environments. This kit helps prevent dust from entering the inverter, extending its service life.
  • UPS Functionality: The inverter features a fast transfer time (10ms typical for UPS applications), allowing it to seamlessly switch to battery power during grid outages, providing an uninterrupted power supply for critical loads.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official PowMr website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for any warranty claims.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.