CNC YCQ1B-63/2P/3P/4P

Contents

CNC YCQ1B-63 Dual Power Automatic Transfer Switch Instruction Manual

Models: YCQ1B-63/2P, YCQ1B-63/3P, YCQ1B-63/4P

1. Product Overview

The CNC YCQ1B-63 Dual Power Automatic Transfer Switch (ATS) is designed to seamlessly switch between two power sources, typically a common power supply (e.g., utility grid) and a standby power supply (e.g., generator or solar inverter). This ensures continuous power to your load in case of an outage from the primary source. The device supports both automatic and manual switching operations, providing flexibility for various applications.

Key features of the YCQ1B-63 series include:

  • Overload Protection
  • Output Analysis Signal
  • Undervoltage Protection
  • Current Protection
Diagram showing the key features of the YCQ1B-63 ATS: Overload Protection, Output Analysis Signal, Undervoltage Protection, Current Protection.
Figure 1: Key Features of the YCQ1B-63 ATS

2. Specifications

AttributeValue
Model NumberYCQ1B-63/2P/3P/4P
Brand NameCNC
TypeMoulded Case Circuit Breaker
Poles Number2P, 3P, 4P
Rated Current10A - 63A
Rated Voltage400V
Operating Voltage220V
Working Frequency50Hz/60Hz
Standards CompliantIEC60947-6-1
Operation MethodAutomatic and Manual
ATS LevelCB
Conversion Time≤2s
Conversion MethodSelf-return
CertificationCE
Is Smart DeviceNo
OriginMainland China

Dimensions (mm)

Diagram showing product dimensions for 2P, 3P, and 4P models. 2P: 150mm width, 138mm height. 3P: 163mm width, 138mm height. 4P: 220mm width, 138mm height. Side view shows 115mm depth.
Figure 2: Product Dimensions for 2P, 3P, and 4P Models
  • 2P Model: Approximately 150mm (width) x 138mm (height)
  • 3P Model: Approximately 163mm (width) x 138mm (height)
  • 4P Model: Approximately 220mm (width) x 138mm (height)
  • Depth (all models): Approximately 115mm

3. Installation and Wiring

WARNING: Installation should only be performed by qualified personnel. Ensure all power sources are disconnected before beginning installation to prevent electric shock or damage to equipment.

General Installation Steps:

  1. Mount the ATS securely in a suitable electrical enclosure using the provided mounting holes.
  2. Identify the common power supply (e.g., utility) and the standby power supply (e.g., generator).
  3. Connect the main power and generator power to their respective input terminals on the ATS.
  4. Connect the load output from the ATS to your electrical panel or distribution board.
  5. Ensure all connections are tight and properly insulated.

Wiring Diagrams:

Refer to the following diagrams for specific wiring configurations for 2P, 3P, and 4P models. The terminals are typically labeled 'N' for Neutral and 'R' for Live/Phase connections.

Detailed wiring diagram for 2P, 3P, and 4P CNC Dual Power Automatic Transfer Switches. Shows connections for Common Fire Wire, Standby Fire Wire, Common Zero Line, Spare Neutral, and Load Output.
Figure 3: Product Wiring Diagram (2P, 3P, 4P)
  • 2P Wiring: Connect Common Fire Wire and Standby Fire Wire to the respective 'N' and 'R' inputs. Connect Load Output.
  • 3P Wiring: Connect Common Fire Wire, Common Zero Line (Position 3), and Standby Fire Wire to the respective inputs. Connect Load Output.
  • 4P Wiring: Connect Common Fire Wire, Common Zero Line (Position 3), Spare Neutral (Position 6), and Standby Fire Wire to the respective inputs. Connect Load Output.

For a visual demonstration of the wiring process, please watch the following video:

Video 1: Wiring Demonstration for CNC Dual Power Automatic Transfer Switch

4. Operation

The YCQ1B-63 ATS features both automatic and manual operation modes, selectable via a switch on the front panel.

Automatic Mode:

In 'Auto' mode, the switch will automatically detect the presence and absence of the common power supply. If the common power supply fails, the ATS will automatically switch to the standby power supply. When the common power supply is restored, the ATS will automatically switch back to the common power supply (self-return function).

Manual Mode:

In 'Manual' mode, you can manually switch between the common and standby power supplies using the rotary knob or lever on the device. This mode is useful for maintenance, testing, or in situations where automatic switching is not desired.

Ensure the switch is in the desired position ('Auto' or 'Manual') for proper operation.

Front view of the CNC YCQ1B-63/4P Dual Power Automatic Transfer Switch, showing the auto/manual selector and power indicators.
Figure 4: Front Panel of the YCQ1B-63 ATS (4P model)

5. Maintenance

Regular maintenance helps ensure the longevity and reliable operation of your ATS.

  • Visual Inspection: Periodically check for any signs of physical damage, loose connections, or overheating (discoloration, burnt smell).
  • Cleaning: Keep the ATS free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquids or abrasive cleaners.
  • Terminal Tightness: Ensure all electrical connections remain tight. Loose connections can lead to overheating and potential failure.
  • Functional Test: Periodically test the automatic switching function by simulating a common power failure (if safe to do so and with proper precautions).

Always disconnect power before performing any maintenance.

6. Troubleshooting

If you encounter issues with your ATS, refer to the following troubleshooting guide:

ProblemPossible CauseSolution
ATS does not switch automatically1. Switch is in 'Manual' mode.
2. No power detected from standby source.
3. Control circuit fault.
1. Set switch to 'Auto' mode.
2. Verify standby power source is active and connected.
3. Consult a qualified electrician.
No power to load after switching1. Loose wiring connections.
2. Overload or short circuit.
3. Faulty ATS unit.
1. Check and tighten all terminal connections (with power off).
2. Check connected loads for faults; reset circuit breakers.
3. Consult a qualified electrician or replace unit.
Overheating or burning smell1. Loose connections.
2. Overload.
3. Internal component failure.
1. Immediately disconnect power. Check and tighten all connections.
2. Reduce load or ensure ATS capacity matches demand.
3. Consult a qualified electrician.

User Tips:

  • Voltage Compatibility: Always verify that the voltage of your power sources (e.g., 220V, 110+110) is compatible with the ATS specifications (Operating Voltage: 220V, Rated Voltage: 400V). Incorrect voltage can damage the unit.
  • Application Versatility: This ATS is suitable for automatically switching between utility power and alternative sources like generators or solar power systems, ensuring seamless power transition for critical loads.
  • Professional Installation: Due to the electrical nature of this device, professional installation is highly recommended to ensure safety and correct functionality.

7. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized dealer. Keep your purchase receipt and product model number handy when contacting support.

© 2024 CNC Electric. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.