ATORCH 4SPQ

Contents

ATORCH Data Line Test Board User Manual

Model: 4SPQ

1. Introduction

This manual provides detailed instructions for the ATORCH Data Line Test Board, Model 4SPQ. It is designed as an accessory for use with ATORCH DL24, DL24MP, and DL24EW electronic loads, facilitating comprehensive testing of various data line types. Please read this manual thoroughly before use to ensure proper operation and safety.

2. Safety Information

  • Always ensure proper and secure connection to compatible ATORCH electronic loads (DL24, DL24MP, DL24EW).
  • Do not exceed the specified voltage and current limits of the connected electronic load or the data cable being tested.
  • Keep the device away from moisture, liquids, and extreme temperatures to prevent damage.
  • Handle the test board and its connectors with care to avoid physical damage.
  • This device is intended for testing purposes only and should not be used as a power supply or for other unintended applications.

3. Product Overview

The ATORCH Data Line Test Board (Model 4SPQ) is a compact and versatile accessory designed to expand the testing capabilities of your ATORCH electronic load. It features multiple input ports to accommodate various data cable standards, enabling a wide range of testing scenarios for different devices.

ATORCH Data Line Test Board
Figure 3.1: ATORCH Data Line Test Board (Model 4SPQ)
ATORCH Data Line Test Board with labeled ports
Figure 3.2: Labeled ports on the Data Line Test Board, showing DC5.5 input detection port, Mini USB input detection port, Micro USB (Android) input detection port, and Type-C (USB-C) input detection port. An LED indicator light is also present. This interface requires insertion into DL24/DL24MP/DL24EW electronic load interfaces.

4. Setup Instructions

  1. **Connect to Electronic Load**: Carefully insert the male connectors of the Data Line Test Board into the corresponding female interfaces of your ATORCH DL24, DL24MP, or DL24EW electronic load. Ensure the connection is firm and fully seated.
  2. **Power On Electronic Load**: Turn on your ATORCH electronic load device according to its specific user manual.
  3. **Prepare Data Cable**: Select the data cable you intend to test. Ensure it is free from visible damage.
  4. **Connect Data Cable**: Plug the data cable into the appropriate input detection port on the Data Line Test Board (DC5.5, Mini USB, Micro USB, or Type-C), matching the cable type.
  5. **Observe LED Indicator**: A successful connection and readiness for testing will typically be indicated by the illumination of the LED indicator light on the test board.

5. Operating Instructions

Once the Data Line Test Board is correctly connected to your electronic load and a data cable is inserted, you can proceed with various tests using the functionalities of your ATORCH electronic load.

  • **Voltage and Current Measurement**: Utilize your electronic load to accurately measure the voltage and current characteristics of the connected data cable.
  • **Load Testing**: Apply different load conditions through your electronic load to evaluate the data cable's performance and stability under varying power demands.
  • **Data Line Integrity**: While the test board provides the connection points, the detailed analysis of data line integrity (e.g., resistance, voltage drop, signal quality) is performed by the connected electronic load. Refer to your electronic load's manual for specific testing procedures.

For detailed instructions on how to perform specific tests, configure settings, and interpret results, please consult the user manual of your ATORCH DL24/DL24MP/DL24EW electronic load.

6. Maintenance

  • **Cleaning**: To clean the test board, use a soft, dry, and lint-free cloth. Avoid using liquid cleaners, solvents, or abrasive materials, as these can damage the components or finish.
  • **Storage**: When not in use, store the Data Line Test Board in a dry, dust-free environment, preferably in its original packaging or a protective case, to prevent damage to the connectors.
  • **Inspection**: Periodically inspect all connectors and the board for any signs of wear, corrosion, or physical damage. If any damage is observed, discontinue use and consider replacement.

7. Troubleshooting

ProblemPossible CauseSolution
LED indicator not lighting up.
  • Test board not properly connected to the electronic load.
  • Data cable not properly inserted into the test board.
  • Electronic load not powered on or experiencing a fault.
  • Faulty data cable.
  • Ensure the test board is securely and fully inserted into the electronic load's interfaces.
  • Verify the data cable is fully plugged into the correct port on the test board.
  • Check the electronic load's power status and functionality.
  • Try a different, known-good data cable.
Inaccurate or no readings on the electronic load.
  • Loose connections between the test board, data cable, or electronic load.
  • Faulty data cable being tested.
  • Issue with the electronic load itself.
  • Incorrect settings on the electronic load.
  • Re-seat all connections firmly.
  • Test with a different, known-good data cable.
  • Consult the electronic load's manual for troubleshooting and calibration.
  • Verify the electronic load's settings are appropriate for the test.

8. Specifications

FeatureDetail
Brand NameATORCH
Model Number4SPQ
DIY Supplies CategoryElectrical
Electronic ComponentNo (Passive Test Board)
High-concerned chemicalNone
OriginMainland China
CertificationCE, RoHS
Compatible Electronic LoadsATORCH DL24, DL24MP, DL24EW
Input PortsDC5.5, Mini USB, Micro USB (Android), Type-C (USB-C)

9. User Tips

  • **Calibration**: For the most accurate results, ensure your ATORCH electronic load is regularly calibrated according to its manufacturer's guidelines.
  • **Cable Selection**: Always use the correct input port on the test board that matches the type of data cable you are testing to prevent damage and ensure proper contact.
  • **Cleanliness**: Keep the test board's connectors free from dust and debris. A clean connection ensures reliable electrical contact and accurate measurements.
  • **Systematic Testing**: When troubleshooting or comparing cables, test them systematically. Use a known-good reference cable to establish a baseline for comparison.

10. Warranty and Support

For information regarding product warranty, technical support, or service inquiries, please refer to the documentation provided with your ATORCH electronic load or contact ATORCH customer service directly. Please retain your purchase receipt as proof of purchase for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.