EASUN POWER ISOLAR-SMG-II-11KW-48V-WIFI

Contents

EASUN 11KW 48V Hybrid Solar Inverter User Manual

Model: ISOLAR-SMG-II-11KW-48V-WIFI

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of the EASUN 11KW 48V Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance of the inverter. This inverter is designed for off-grid solar applications, featuring a pure sine wave output, high PV input voltage range, and integrated MPPT solar charging.

Key Features:

  • 11KW 48V Hybrid Solar Inverter
  • Off-Grid operation
  • 220/230/240VAC Output Voltage
  • Pure Sine Wave output with Power Factor 1.0
  • Max PV Input 500VDC
  • Built-in 160A MPPT Solar Charge Controller
  • Built-in WIFI for remote monitoring (optional)
  • Supports Lithium battery activation and communication via RS485 (BMS)
  • Capable of working without a battery
  • Detachable dust cover for harsh environments
  • Configurable input voltage range and charging priorities
  • Overload, over temperature, and short circuit protection
  • Cold start function
  • EQ function for battery performance optimization

2. Safety Information

Before installing or using the inverter, please read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual. Improper operation may cause damage to the unit, serious injury, or death. Keep this manual for future reference.

3. Package Contents

Upon unpacking, please verify that all items listed below are included and undamaged:

  • EASUN 11KW 48V Hybrid Solar Inverter Unit
  • User Manual
  • Communication Cables (RS232/RS485)
  • WIFI Module (Optional)
  • PV Connectors
  • Mounting Screws and accessories

Unboxing Video:

4. Product Overview

Front Panel:

Front panel of the EASUN Hybrid Solar Inverter showing LCD display, status indicators, and function buttons.

The front panel features an LCD display, LED indicators, and function buttons for monitoring and configuration.

  • LCD display: Shows system status and settings.
  • Status indicator: Indicates the operational status of the inverter.
  • Charging indicator: Shows battery charging status.
  • Fault indicator: Alerts to system faults or warnings.
  • Function buttons: Used for navigation and setting adjustments.

Rear Panel Connections:

Rear panel of the EASUN Hybrid Solar Inverter with labeled connection ports.
  1. Solar input-1
  2. Solar input-2
  3. AC input
  4. AC output
  5. Grounding
  6. Dry contact
  7. WiFi (Optional)
  8. RS485 communication port
  9. RS232 communication port
  10. Battery input
  11. Power on/off switch

5. Installation & Setup

Mounting the Unit:

Diagram showing mounting instructions and clearance requirements for the inverter.

Consider the following points before selecting where to install:

  1. Do not mount the inverter on flammable construction materials.
  2. Mount on a solid surface.
  3. Install this inverter at eye level in order to allow the LCD display to be read at all times.
  4. The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  5. The recommended installation position is to be adhered to the wall vertically.
  6. Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

WARNING: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

System Connection Diagrams:

System diagram illustrating connections for solar power, generator, utility grid, battery packs, and home appliances, both with and without battery connected.

The diagram illustrates typical system connections for the hybrid solar inverter, showing configurations for operation with and without battery packs, integrating solar power, a generator, and the utility grid to power home appliances.

PV Connection:

PV connection diagram and parameters for selecting proper PV modules.

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.

Battery Connection:

Battery connection diagram for a 48VDC system using four 12V batteries.

The 11KW model supports a 48VDC system. Connect four 12V batteries in series as shown in the diagram to achieve the required 48VDC.

6. Operation

LCD Display and Function Keys:

The LCD display provides real-time information about the inverter's status. Use the function keys to navigate through menus and adjust settings.

LED Indicator Messages
LED IndicatorColorStateMessages
AC / INVGreenSolid OnOutput is powered by utility in Line mode.
GreenFlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
GreenFlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
RedFlashingWarning condition occurs in the inverter.
Function Keys Description
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your EASUN Hybrid Solar Inverter.

  • Dust Cover: The inverter features a detachable dust cover. Regularly clean the dust cover and the inverter's ventilation openings to prevent dust accumulation, which can hinder cooling and affect performance.
  • Battery Maintenance: Utilize the inverter's EQ function to optimize battery performance and extend its lifecycle. Follow battery manufacturer guidelines for specific maintenance procedures.
  • Connection Checks: Periodically inspect all electrical connections for tightness and signs of corrosion. Ensure all cables are securely fastened.
  • Environmental Conditions: Ensure the installation environment remains within the specified temperature and humidity ranges to prevent damage to the unit.

8. Troubleshooting

The inverter is equipped with various protection mechanisms. Refer to the LED Indicator Messages table in the Operation section for fault and warning conditions. If a fault occurs, the red FAULT indicator will illuminate or flash.

  • Overload Protection: If the load connected to the inverter exceeds its capacity (e.g., 140% load for 5 seconds or 110-140% load for 10 seconds), the inverter will trigger an overload protection. Reduce the connected load to resume normal operation.
  • Over Temperature Protection: If the internal temperature of the inverter exceeds safe limits, it will shut down to prevent damage. Ensure adequate ventilation and proper clearance around the unit as per mounting instructions.
  • Short Circuit Protection: In case of a short circuit at the output, the inverter will immediately shut down. Disconnect the load and check for any wiring issues before restarting.
  • AC Recovery: The inverter features an auto-restart function when AC power is recovered after an interruption.

For persistent issues, consult the detailed troubleshooting section in the full user manual or contact customer support.

9. Specifications

General Specifications (ISolar-SMG-II-11KW-48V-WiFi):

Key specifications of the EASUN Hybrid Solar Inverter including frequency, voltage, power, and communication.
  • Frequency Range: 50Hz/60Hz (Auto sensing)
  • Battery Voltage: 48VDC
  • Max Output Power: 11000W
  • Wave Form: Pure Sine Wave
  • Output Voltage: 220/230/240 VAC
  • Parallel Support: Not Supported
  • Solar Charge Current: 160A
  • PV Open Circuit Voltage: 500VDC
  • Communication: RS232/RS485/DRY CONTACT

Detailed Technical Specifications:

EASUN Hybrid Solar Inverter Specifications Comparison
MODELISolar-SMG-II-8.5KW-48V-WiFiISolar-SMG-II-11KW-48V-WiFi
Capacity8.5KVA/8.5KW11KVA/11KW
Maximum PV Input Power10KW11KW
Parallel CapabilityNONO
Lithium Battery ActivationYES (By PV or Utility)
Lithium Battery CommunicationYES (RS485)
INPUT
Nominal Voltage230VAC
Acceptable Voltage Range170-280VAC (For personal Computer); 90-280VAC (For Home Appliances)
Frequency50/60Hz (Auto sensing)
OUTPUT
Nominal Voltage220/230/240VAC
Surge Power17000VA22000VA
Frequency50/60Hz
WaveformPure Sinewave
Transfer Time10ms (For personal Computer); 20ms (For Home Appliances)
Peak Efficiency94%
Overload Protection5s @ >=140% load; 10s @ 110%~140% load
Admissible Power Factor0.6~1 (inductive or capacitive)
BATTERY
Battery Voltage48VDC48VDC
Maximum Discharge Current180A220A
Floating Charge Voltage54VDC54VDC
Over Charge Protection63VDC63VDC
Charging MethodCC/CV
SOLAR CHARGER & AC CHARGER
Solar Charger TypeMPPTMPPT
Max. PV Array Power5000W*25500W*2
Max. PV Array Open Circuit Voltage500VDC500VDC
PV Array MPPT Voltage Range60VDC~500VDC60VDC~500VDC
Max. Solar Input Current18A*218A*2
Max. Solar Charge Current140A160A
Max. AC Charge Current120A120A
Max. Charge Current140A160A
PHYSICAL
Dimensions (DxWxH) (mm)540*415*122540*415*122
Net Weight (Kgs)1415
Communication InterfaceRS232/RS485/DRY CONTACT
LCDYES
ENVIRONMENT
Operating Temperature Range-10°C to 55°C
Storage Temperature-15°C~60°C
Humidity5% to 95% Relative Humidity (Non-condensing)

10. Warranty and Support

Warranty Information:

Warranty information for EASUN products.

EASUN Power offers a 12-month warranty on its solar inverters. For specific details regarding warranty claims or technical support, please refer to your purchase documentation or contact EASUN Power customer service.

Customer Support:

For any questions, inquiries, or technical assistance regarding your EASUN Hybrid Solar Inverter, please contact our customer service. We are committed to providing comprehensive support to ensure your satisfaction.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.