1. Introduction
This manual provides essential information for the installation, operation, and maintenance of the EASUN 11KW 48V Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance of the inverter. This inverter is designed for off-grid solar applications, featuring a pure sine wave output, high PV input voltage range, and integrated MPPT solar charging.
Key Features:
- 11KW 48V Hybrid Solar Inverter
- Off-Grid operation
- 220/230/240VAC Output Voltage
- Pure Sine Wave output with Power Factor 1.0
- Max PV Input 500VDC
- Built-in 160A MPPT Solar Charge Controller
- Built-in WIFI for remote monitoring (optional)
- Supports Lithium battery activation and communication via RS485 (BMS)
- Capable of working without a battery
- Detachable dust cover for harsh environments
- Configurable input voltage range and charging priorities
- Overload, over temperature, and short circuit protection
- Cold start function
- EQ function for battery performance optimization
2. Safety Information
Before installing or using the inverter, please read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual. Improper operation may cause damage to the unit, serious injury, or death. Keep this manual for future reference.
3. Package Contents
Upon unpacking, please verify that all items listed below are included and undamaged:
- EASUN 11KW 48V Hybrid Solar Inverter Unit
- User Manual
- Communication Cables (RS232/RS485)
- WIFI Module (Optional)
- PV Connectors
- Mounting Screws and accessories
Unboxing Video:
4. Product Overview
Front Panel:

The front panel features an LCD display, LED indicators, and function buttons for monitoring and configuration.
- LCD display: Shows system status and settings.
- Status indicator: Indicates the operational status of the inverter.
- Charging indicator: Shows battery charging status.
- Fault indicator: Alerts to system faults or warnings.
- Function buttons: Used for navigation and setting adjustments.
Rear Panel Connections:

- Solar input-1
- Solar input-2
- AC input
- AC output
- Grounding
- Dry contact
- WiFi (Optional)
- RS485 communication port
- RS232 communication port
- Battery input
- Power on/off switch
5. Installation & Setup
Mounting the Unit:

Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
WARNING: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
System Connection Diagrams:

The diagram illustrates typical system connections for the hybrid solar inverter, showing configurations for operation with and without battery packs, integrating solar power, a generator, and the utility grid to power home appliances.
PV Connection:

When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
Battery Connection:

The 11KW model supports a 48VDC system. Connect four 12V batteries in series as shown in the diagram to achieve the required 48VDC.
6. Operation
LCD Display and Function Keys:
The LCD display provides real-time information about the inverter's status. Use the function keys to navigate through menus and adjust settings.
| LED Indicator | Color | State | Messages |
|---|---|---|---|
| AC / INV | Green | Solid On | Output is powered by utility in Line mode. |
| Green | Flashing | Output is powered by battery or PV in battery mode. | |
| CHG | Green | Solid On | Battery is fully charged. |
| Green | Flashing | Battery is charging. | |
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Red | Flashing | Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your EASUN Hybrid Solar Inverter.
- Dust Cover: The inverter features a detachable dust cover. Regularly clean the dust cover and the inverter's ventilation openings to prevent dust accumulation, which can hinder cooling and affect performance.
- Battery Maintenance: Utilize the inverter's EQ function to optimize battery performance and extend its lifecycle. Follow battery manufacturer guidelines for specific maintenance procedures.
- Connection Checks: Periodically inspect all electrical connections for tightness and signs of corrosion. Ensure all cables are securely fastened.
- Environmental Conditions: Ensure the installation environment remains within the specified temperature and humidity ranges to prevent damage to the unit.
8. Troubleshooting
The inverter is equipped with various protection mechanisms. Refer to the LED Indicator Messages table in the Operation section for fault and warning conditions. If a fault occurs, the red FAULT indicator will illuminate or flash.
- Overload Protection: If the load connected to the inverter exceeds its capacity (e.g., 140% load for 5 seconds or 110-140% load for 10 seconds), the inverter will trigger an overload protection. Reduce the connected load to resume normal operation.
- Over Temperature Protection: If the internal temperature of the inverter exceeds safe limits, it will shut down to prevent damage. Ensure adequate ventilation and proper clearance around the unit as per mounting instructions.
- Short Circuit Protection: In case of a short circuit at the output, the inverter will immediately shut down. Disconnect the load and check for any wiring issues before restarting.
- AC Recovery: The inverter features an auto-restart function when AC power is recovered after an interruption.
For persistent issues, consult the detailed troubleshooting section in the full user manual or contact customer support.
9. Specifications
General Specifications (ISolar-SMG-II-11KW-48V-WiFi):

- Frequency Range: 50Hz/60Hz (Auto sensing)
- Battery Voltage: 48VDC
- Max Output Power: 11000W
- Wave Form: Pure Sine Wave
- Output Voltage: 220/230/240 VAC
- Parallel Support: Not Supported
- Solar Charge Current: 160A
- PV Open Circuit Voltage: 500VDC
- Communication: RS232/RS485/DRY CONTACT
Detailed Technical Specifications:
| MODEL | ISolar-SMG-II-8.5KW-48V-WiFi | ISolar-SMG-II-11KW-48V-WiFi |
|---|---|---|
| Capacity | 8.5KVA/8.5KW | 11KVA/11KW |
| Maximum PV Input Power | 10KW | 11KW |
| Parallel Capability | NO | NO |
| Lithium Battery Activation | YES (By PV or Utility) | |
| Lithium Battery Communication | YES (RS485) | |
| INPUT | ||
| Nominal Voltage | 230VAC | |
| Acceptable Voltage Range | 170-280VAC (For personal Computer); 90-280VAC (For Home Appliances) | |
| Frequency | 50/60Hz (Auto sensing) | |
| OUTPUT | ||
| Nominal Voltage | 220/230/240VAC | |
| Surge Power | 17000VA | 22000VA |
| Frequency | 50/60Hz | |
| Waveform | Pure Sinewave | |
| Transfer Time | 10ms (For personal Computer); 20ms (For Home Appliances) | |
| Peak Efficiency | 94% | |
| Overload Protection | 5s @ >=140% load; 10s @ 110%~140% load | |
| Admissible Power Factor | 0.6~1 (inductive or capacitive) | |
| BATTERY | ||
| Battery Voltage | 48VDC | 48VDC |
| Maximum Discharge Current | 180A | 220A |
| Floating Charge Voltage | 54VDC | 54VDC |
| Over Charge Protection | 63VDC | 63VDC |
| Charging Method | CC/CV | |
| SOLAR CHARGER & AC CHARGER | ||
| Solar Charger Type | MPPT | MPPT |
| Max. PV Array Power | 5000W*2 | 5500W*2 |
| Max. PV Array Open Circuit Voltage | 500VDC | 500VDC |
| PV Array MPPT Voltage Range | 60VDC~500VDC | 60VDC~500VDC |
| Max. Solar Input Current | 18A*2 | 18A*2 |
| Max. Solar Charge Current | 140A | 160A |
| Max. AC Charge Current | 120A | 120A |
| Max. Charge Current | 140A | 160A |
| PHYSICAL | ||
| Dimensions (DxWxH) (mm) | 540*415*122 | 540*415*122 |
| Net Weight (Kgs) | 14 | 15 |
| Communication Interface | RS232/RS485/DRY CONTACT | |
| LCD | YES | |
| ENVIRONMENT | ||
| Operating Temperature Range | -10°C to 55°C | |
| Storage Temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
10. Warranty and Support
Warranty Information:

EASUN Power offers a 12-month warranty on its solar inverters. For specific details regarding warranty claims or technical support, please refer to your purchase documentation or contact EASUN Power customer service.
Customer Support:
For any questions, inquiries, or technical assistance regarding your EASUN Hybrid Solar Inverter, please contact our customer service. We are committed to providing comprehensive support to ensure your satisfaction.