PowMr POW-Keeper1220, POW-Keeper1230, POW-Keeper1240

Contents

PowMr MPPT Solar Charge Controller User Manual

Models: POW-Keeper1220, POW-Keeper1230, POW-Keeper1240

Brand: PowMr

1. Introduction

Thank you for selecting the MPPT series solar charge controller. This device incorporates the most advanced MPPT control algorithm, enabling it to quickly track the maximum power point of the PV array in any environment. This ensures maximum energy extraction from the solar panel and significantly improves the energy utilization efficiency of your solar system.

The controller features a dual display function (LCD and optional Remote header) and a standard communication interface, facilitating user extension applications and meeting diverse monitoring needs. It is suitable for various applications including communication base stations, home power supply systems, traffic lights, solar street lamps, and courtyard lamp systems.

2. Safety Information and Precautions

Important Safety Notice:

  • Always connect the battery first, then the solar panel, after setting the system parameters. Failure to follow this order may result in battery damage.
  • This MPPT series controller is a common positive controller. The positive poles of the PV array, battery, and load can be grounded simultaneously.
  • If an inverter or other high-current load is used in the system, connect it directly to the battery. Do not connect it to the controller's load terminal.
  • When using lithium batteries, ensure you set the system voltage and the correct battery type before use. Refer to sections 3.7 Setting Pages and 3.9 System Voltage Setting for details.

3. Package Contents

The PowMr Keeper series package typically includes the following items:

  • 1 x PowMr MPPT Solar Charge Controller
  • 1 x User Manual
  • 1 x Installation Guide Card
PowMr Keeper series controller and manual in box
PowMr Keeper series controller and manual in box.
Video: Overview of the PowMr Keeper series solar charge controller, its features, and package contents.

4. Product Features

The PowMr MPPT Solar Charge Controller offers a range of advanced features for optimal solar system performance:

  • Advanced MPPT Technology: Utilizes Maximum Power Point Tracking technology with a tracking efficiency of no less than 99.5%.
  • High Conversion Efficiency: Built with high-quality components, achieving a maximum conversion efficiency of 97%.
  • Fast Tracking Speed: Super-fast maximum power tracking speed ensures efficient energy harvesting.
  • Accurate MPPT: Capable of accurate identification and tracking of multi-wave peak maximum power points.
  • Reliable PV Input: Designed to handle reliable maximum input power from the PV array, ensuring equipment safety.
  • Wide Operating Voltage Range: Supports a wide operating voltage range for the PV array.
  • Automatic Voltage Identification: Automatically identifies 12V/24V system voltages.
  • Dynamic LCD Display: The LCD dynamically displays operation data and working status.
  • Multiple Load Control Modes: Includes general mode, light control mode, dual time mode, pure charger mode, and timing mode.
  • Battery Compatibility: Supports various battery types including Seal, GEL, Flooded, LifePO4, and Li(NiCoMn)O2 charging processes.
  • Temperature Compensation: Features battery temperature compensation for optimized charging.
  • Power Statistics: Includes a power statistics recording function.
  • Dual USB Ports: Equipped with dual USB ports for convenient charging of external devices.
Advanced MPPT technology with dual USB ports
Advanced MPPT technology with dual USB ports, showing MPPT+PWM charging and 99% tracking efficiency.
Solar panel connection to controller
Solar panel connection to controller, illustrating 98% tracking efficiency and 99% conversion efficiency.

5. Specifications

Below are the detailed technical specifications for the PowMr Keeper series MPPT Solar Charge Controllers:

Overview of Keeper MPPT Solar Charge Controller features and specifications
Overview of Keeper MPPT Solar Charge Controller features and specifications.
General Specifications
ParameterPOW-Keeper1220POW-Keeper1230POW-Keeper1240
Rated charge current20A30A40A
System rated voltage12V/24V Auto work
Voltage range of battery8-32V
Max open voltage of PV module55VDC (POW-Keeper1220); 100VDC (POW-Keeper1230, POW-Keeper1240)
Battery typeUser default, Sealed, Flooded, GEL, LiFePO4
Maximum PV input power (12V/24V)240W(12V); 480W(24V)360W(12V); 720W(24V)480W(12V); 960W(24V)
Equalized charging voltageMaintenance-free lead acid battery: 14.6V; GEL: No; Lead acid flooded battery: 14.8V
Absorption charging voltageMaintenance-free lead acid battery: 14.4V; GEL: 14.2V; Lead acid flooded battery: 14.6V
Floating charging voltageMaintenance-free lead acid battery, GEL, Lead acid flooded battery: 13.8V
Low voltage re-connection (LVR)Maintenance-free lead acid battery, GEL, Lead acid flooded battery: 12.6V
Low voltage disconnection (LVD)Maintenance-free lead acid battery, GEL, Lead acid flooded battery: 10.8V
Static loss<9.2mA 12V; <11.7mA 24V
High voltage disconnection (HVD)16V (24V x 2)
Duration of absorption charging2 Hours
Light control voltage5V
Charge loop voltage drop<0.29V
LCD Temperature-20°C~+70°C
Operating Temperature-20°C~+55°C (To run at full rated current continuously)
Storage temperature-30°C~+80°C
Working humidity<95% No condensation
Protection classIP30
Grounded typePositive grounded
Aperture for installationΦ5mm
Dimension (LxWxH) mm123x178x48135x202x55150x220x67

*Note: Above parameters are for a 12V system at 25°C; values are doubled for a 24V system.

6. Setup and Installation

Follow these steps carefully to connect and install your solar charge controller:

6.1 Wiring Diagram

The following diagram illustrates a typical solar energy system wiring. Ensure all connections are secure and correctly polarized.

Solar energy system wiring diagram
Solar energy system wiring diagram.

6.2 Connection Steps

Perform the following steps to connect cables and install the controller:

  1. Open the cover: First, open the cover of the controller to access the screw terminals.
  2. Wire the battery: Connect the battery cables to the controller terminals. Ensure correct polarity (positive to positive, negative to negative).
  3. Wire the solar panels (PV): Connect the solar panel cables to the controller terminals. Ensure correct polarity.
  4. Connect the load: Connect your DC load to the designated load terminals on the controller.
  5. (Optional) Connect inverter: If using an inverter, connect it directly to the battery, not to the controller's load terminal.
Step-by-step wiring instructions for the solar charge controller
Step-by-step wiring instructions for the solar charge controller.
Installation steps and LCD display overview
Detailed installation steps and LCD display overview.

7. Operating Instructions

7.1 LCD Display Overview

The LCD screen provides real-time information about the system's status. Key icons and their meanings are:

LCD display icons and their meanings
LCD display icons and their meanings.
LCD Status Indicators
ItemIconStatus
PV arrayPV array iconDay / Night
Charging iconCharging
BatteryBattery iconUncharged / Battery capacity
LiPo / LiFeBattery type
LoadLoad iconLoad on / Load off

7.2 Button Functions

The controller has two main buttons: MENU and SET.

Button Definitions
ButtonFunction
MENUShort press to switch down through pages. Hold for 3 seconds to enter the next interface (e.g., setting pages).
SETShort press to switch up through pages. Press and hold for 3 seconds to exit without saving changes.

7.3 Boot Screen and Initial Display

When the controller powers on, the LCD will display a starting interface, followed by the battery voltage and then the software revision. This is normal system initialization.

Notice:

From the first interface, long press the "MENU" button for 3 seconds to enter the secondary interface. If no action is taken for 15 seconds, it will automatically revert to the first interface.

7.4 Load Switch On/Off

On the main display page, a short press of the "SET" button will toggle the load output on or off. This function is available in any load operating mode.

7.5 Main Loop Pages

After the controller is powered on, the LCD screen will enter the main page. From this page, you can short press "MENU" or "SET" to cycle through various main loop pages, displaying information such as battery temperature, charging current, discharging current, accumulated charging AH, and accumulated discharging AH.

7.6 Setting Pages

To enter the setting pages from the main page, long press "MENU" for 3 seconds. Once in the setting pages, short press "MENU" or "SET" to navigate between different settings. To save changes, long press "MENU" for 3 seconds. To exit without saving, long press "SET" for 3 seconds.

7.7 Battery Type Configuration

From the main page, long press "MENU" for 3 seconds to enter the setting page, then short press "MENU" to navigate to the battery type page (user mode 1). Long press "MENU" again for 3 seconds to enter the battery type selection pages. Use short presses of "MENU" or "SET" to choose between GEL, Sealed, Flooded, and Lithium batteries.

For lithium batteries, after selecting the type, long press "MENU" for 3 seconds to set the capacity. The parameters on screen will flash. Use short presses of "MENU" or "SET" to adjust the capacity. Long press "MENU" for 3 seconds to save.

Important: For lithium batteries, always set the system voltage before selecting the battery type.

Battery Type Display Codes
DisplayBattery type
USE 1Lead-acid battery custom
GELColloidal lead acid battery
SLDSealed lead acid battery
FLDValve-Regulated Lead-Acid Battery
4*3.24S LiFePO4 battery
5*3.25S LiFePO4 battery
3*3.73S Lithium-ion battery
4*3.74S Lithium-ion battery
USE 2Lithium battery custom

7.8 System Voltage Setting

After configuring the battery type, proceed to the system voltage setting. "AUTO" indicates automatic detection of the system voltage. To change, enter the setting pages, switch to the system voltage page, and long press "MENU" for 3 seconds until "AUTO" flashes. Then, short press "MENU" or "SET" to select 12V or 24V.

7.9 Load Working Mode

The controller defaults to load working 24 hours. There are four load working modes available:

Load Working Modes
IconDescription
Ld1Regular mode: The load works normally and can be turned on or off manually.
Ld2Light control mode: The load automatically turns on at dark and turns off at dawn.
Ld3Light & time control mode: Load working hours after dark, load working hours before dawn. (Automatically identifies dark and light according to local environment). If this mode is selected, you can configure the duration of DC output. Once set, the LD3 mode can be activated/deactivated by selecting "on" or "off" in the switch interface.
Ld4Reverse light control mode: Load automatically turns on at dawn, load automatically turns off at dark.

In light control mode, time and light control mode, and reverse light control mode, the controller will start or stop the load with a delay of approximately 30 seconds after the light is detected or disappears.

7.10 PV Voltage Page

Long press "SET" for 3 seconds to switch between the main page and the PV voltage page, which displays the current voltage from your solar panels.

7.11 Equalization and Absorption Charging Duration Settings

To set the duration for equalization or absorption charging, navigate to the respective charging page from the main page. Long press "MENU" for 3 seconds until the parameter starts to flash. Continue pressing "MENU" for 3 seconds to enter the duration setting page. Use short presses of "MENU" or "SET" to increase or decrease the time. Long press "MENU" for 3 seconds to save the setting.

8. Maintenance

To ensure optimal performance and longevity of your PowMr MPPT Solar Charge Controller, regular maintenance is recommended:

  • Periodically inspect all wiring connections for tightness and corrosion.
  • Ensure the controller's heat sink (fins on the side/back) is free from dust and debris to allow for proper heat dissipation.
  • Check the battery terminals for any signs of corrosion and clean if necessary.
  • Verify that the solar panels are clean and free from obstructions.
  • Monitor the LCD display for any error codes or unusual readings.

9. Troubleshooting

9.1 Protection Functions

The controller includes several protection features to safeguard your system:

Protection Functions and Status
ProtectionConditionStatus
Solar panel reversedSolar panel can be reversed if battery is not connected.Controller isn't broken.
Battery is reversedBattery can be reversed if PV is unconnected.Controller isn't broken.
Battery over-voltageBattery voltage reaches the over-voltage point.Stop charging and discharging.
Battery over-dischargeBattery voltage drops below the under-voltage point.Stop discharging.
Over-loadThe load current is over the rated current.Turn off the output.

9.2 Fault Management and Error Codes

If an issue occurs, the controller may display an error code. Refer to the table below for common fault codes and their corrections:

Fault Codes and Corrections
Error codeCauseCorrection
PV array indicator is off (sunlight is enough)Solar panel is disconnected.Check if PV array connection is proper.
No sign on the LCD (connection is right)1. Battery voltage is less than 8V.
2. Voltage of solar panel is less than battery voltage.
1. Check battery voltage (at least 8V to activate the controller).
2. The voltage of PV must be higher than battery voltage.
E1 (Ex1)Battery over discharge.The load will stop automatically and recover when battery voltage reaches 12.6V (LVR).
E2 (Ex2)Battery over voltage.Make sure the settled value of high voltage disconnection voltage is over battery voltage and reconnect PV array.
E3 (Ex3)Over load.Reduce load or check load connection.
E5 (Ex5)Controller overheating.The controller will restart after it cools down.
E6 (Ex6)Input voltage of solar panel is too high.Check voltage of solar panel and reduce quantities of solar panel in series.
E7 (Ex7)No operation.Controller will restart after setting system voltage.

The fault code consists of an "E" and two digits. The first digit represents the current error count, and the second digit indicates the specific fault condition. For example, if the fault code displays as "E-12," it means there is one error at the moment, and the specific reason is overvoltage in the battery.

10. User Tips

  • MPPT vs. PWM: The PowMr Keeper series controllers primarily utilize advanced MPPT technology for efficient power tracking and charging. For battery safety, when the battery voltage reaches a high voltage disconnection point, the controller will automatically switch to PWM charging to optimize battery performance and extend battery life.
  • Lithium Battery Setup: Always remember to set the system voltage and then the specific lithium battery type in the controller's settings before initial use to prevent damage and ensure proper charging.

11. Warranty and Support

For technical support, warranty claims, or further inquiries, please contact the manufacturer:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

  • Telephone/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Website: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

A detailed user manual (PDF) is available for download for further information. You can access it via the official website or by contacting support.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.