Tuya WiFi Smart Electric 3 way Ball Valve

Contents

Tuya WiFi Smart Water Valve 3 Way Motorized Electric Ball Valve Smart Switch Timing Smart Life APP Alexa Google Home User Manual

Brand: Tuya | Model: WiFi Smart Electric 3 way Ball Valve

Tuya WiFi Smart Water Valve with smart switch and smartphone app

Image: The main product components including the motorized ball valve, the smart WiFi switch, and a smartphone displaying the control app.

1. Introduction

This motorized ball valve is designed to control the on-off function of air-conditioning water systems. It comprises an actuator and a valve body. The actuator (driver) utilizes a synchronous motor to rotate the valve body by 90 degrees. It features a built-in limit relay contact that automatically cuts off power when the valve is fully open or closed.

2. Package Contents

Your package should include:

  • 1x Motorized 3 Way Ball Valve
  • 1x WiFi Smart Switch

3. Specifications

3.1. Main Technical Parameters

ParameterValue
Power SupplyDC24V, DC12V, AC220V ±10%, 50/60Hz (Max. Voltage: AC90-250V for Smart Switch)
Power Consumption6W (Only when the valve is open or closed)
Motor TypeSynchronous motor
Running Time≤15S (Bi-directional motor); <15S (Single-directional motor)
General Pressure2.5MPa (Valve body pressure resistance: 1.6mpa)
Connection WayPipe screw thread G (T/L type)
Applied MediumCold water, hot water or 50% liquor of glycol water liquor
Medium Temperature0~90℃
Grade of ProtectionIP54
Valve Body MaterialForging Brass, Nickel plated Surface
Actuator MaterialOuter Cover: ABS+PC Engineering Plastics (antiflaming), Base: PA66+30%GF
Wireless StandardIEEE802.11b/g/n
Radio ProtocolWi-Fi 2.4GHz
CertificationCE

3.2. Dimensions and Port Sizes

Motorized Ball Valve size table with dimensions

Image: A diagram showing the motorized ball valve with labels for Length, Width, High, Thread diameter, and Ball Bore, alongside a detailed size table.

Nominal DiameterBall BoreLength (mm)High (mm)Width (mm)Thread Diameter (mm)
DN15 (1/2" 4 points)10mm55mm120mm43mm20mm
DN20 (3/4" 6 points)14mm67mm130mm52mm25mm
DN25 (1" 1 inch)17mm80mm137mm62mm32mm
DN32 (1-1/4" 1.2 inches)24mm98mm152mm75mm40mm
DN40 (1-1/2" 1.5 inches)30mm120mm157mm93mm50mm

Note: The size is measured by hand, there may be an error of 1-3mm. All specifications are subject to the actual product.

Multiple motorized ball valves of different sizes

Image: A display of various sizes of motorized ball valves, illustrating the range of available port sizes.

3.3. Solenoid Valve vs. Motorized Ball Valve Comparison

Comparison table between Solenoid Valve and Motorized Ball Valve

Image: A table comparing the features and characteristics of a Solenoid Valve and a Motorized Ball Valve, including installation method, power-on time, medium flow, power consumption, running time, and flow rate.

4. Safety Warnings

Warning:

The symbol ⚠ indicates that the unit is being installed. It may cause an electrical shock hazard during maintenance. Please ensure that installation and maintenance are performed by a professional technical worker.

5. Setup and Installation

5.1. Installation Notices

  • The actuator must be installed on a horizontal line.
  • Do not apply excessive force to the actuator during installation.
  • The screw thread of the valve must conform to the international standard of tube screw (G screw). Do not use taper screw thread to connect the valve.
  • Before installation, ensure the valve and the pipeline are clean and free of sundries.
  • The valve and pipeline should be installed horizontally or vertically. Upside-down installation is forbidden.
  • Maintain the temperature of the pipeline and the valve.
  • Do not place the actuator inside a protected cover.
  • Attention: When assembling the actuator and valve body, the angle of the actuator power down-lead and valve body should be 90°.

5.2. Connection Diagram of Actuator and Valve Body

Connection diagram of actuator and valve body

Image: A diagram illustrating the steps to connect the actuator to the valve body. It shows pressing the convex plate of the actuator into the groove of the valve body and then screwing the nut until it stops.

  1. Press vertically the convex plate of the actuator into the groove of the valve body.
  2. Screw the nut on the actuator in the direction of the arrow until it stops.

6. Wiring Instructions

6.1. Wiring Method Description (Two-wire power-off reset mode)

Wiring method description diagram

Image: A wiring diagram showing the connection of the smart switch (Actuator External Controller) to the valve actuator (Inside the actuator) with blue and yellow/blue lines, and a backup power source.

  • Note: The power-on time shall not be less than 1 minute. The positive and negative wiring shall be strictly in accordance with the wiring diagram and shall not be reversed.
  • Normally Closed:
    • When the SW (switch) is closed, the valve opens/closes. After the position is in place, the internal power is automatically cut off. The valve remains on/off and the backup power is charged.
    • When the SW is disconnected, the valve is closed/opened. After it is in place, the internal power is automatically cut off. The valve remains closed/open.
  • Normally Open:
    • Power on, power off triggers backup power off.
    • Power on off, power off triggers backup power on.

7. Operation

7.1. Smart Control Features

  • Voice Control: Connect the smart switch with Amazon Alexa (Amazon Echo/Dot/Tap) or Google Assistant for convenient voice control of your valve.
  • Wi-Fi Remote Control: Use the "Smart Life" APP on your smartphone to control the switch wirelessly via Wi-Fi or 4G network. No additional hub is required.
  • Timing Function: Schedule exact times to turn the valve on/off automatically, allowing full control over your water system.
  • Device Sharing: The smart switch supports device sharing, allowing multiple family members to control the valve. One mobile phone can also control multiple switches.
  • IFTTT Integration: Utilize IFTTT ("If This, Then That") to create custom automations for your valve, such as turning it on before you arrive home or off when you leave.
Smart home compatibility with Amazon Alexa, Google Assistant, and IFTTT

Image: Illustrates compatibility with Amazon Alexa, Google Assistant, and IFTTT, showing various smart home devices.

Remote control from anywhere via smartphone app

Image: Demonstrates controlling the valve remotely using a smartphone app, allowing operation from any location.

Timing, Countdown, and Schedule functions via app

Image: Shows the app interface for setting up timing, countdown, and recurring schedules for valve operation.

Sharing function for family members to control devices

Image: Depicts the device sharing feature, allowing a main account to grant control permissions to other family members.

7.2. Valve Flow Direction and States

Diagram explaining Normally Closed and Normally Open valve states (A, B, C ports)

Image: A diagram of the 3-way ball valve showing ports A, B, and C, with explanations for Normally Closed and Normally Open configurations.

  • Normally Closed:
    • When powered on, ports A and B are open, and port C is closed.
    • When powered off, port C is open to port B, and port A is closed (ports A and C are always closed).
  • Normally Open:
    • When powered on, ports B and C are open, and port A is closed.
    • When powered off, ports A and B are open, and port C is closed (ports A and C are always closed).

8. Maintenance

To ensure optimal performance and longevity of your valve:

  • Regularly check the valve and pipeline for any accumulated sundries or impurities. Clean as necessary.
  • Consider installing a pre-placed filter in your water system to prevent debris from entering the valve.
  • If the valve is exposed to harsh conditions, ensure the actuator is not placed inside a protected cover that might trap heat or moisture.

9. Troubleshooting

9.1. Abnormal Problems and Solutions

ItemAbnormalityReasonsSolutions
1Valve opening and closing positions are oppositeWrong wire connectionExchange the valve opening wire and closing wires.
2The actuator does not runWrong wire connection, the circuitry is burnt, or the actuator suffers water/motor damage.Check the power supply and the circuitry of the thermostat. Exchange the actuator if damaged.
3The connection of the screw thread is crackedUsed wrong screw, improper installation, or over force installation.Exchange the valve body.
4The valve cannot be open or closed thoroughlyJammed with sundries or bad quality water.Clean up the sundries or add a pre-placed filter.

10. User Tips

  • Understand Valve States: Familiarize yourself with the "Normally Closed" and "Normally Open" configurations (Section 7.2) to ensure the valve operates as expected for your specific application.
  • Prevent Leaks: Some users have reported issues with water passing through when the valve is in the closed position. Ensure proper installation, tight connections, and check for any debris that might prevent the valve from sealing completely.
  • Wiring Precision: Always double-check your wiring against the provided diagram. Incorrect polarity or loose connections can lead to malfunction or damage.

11. Warranty and Support

This product typically comes with a 1-year warranty from the store. For further guides and documents, please refer to the official PDF user manual available from the seller.

Remarks: If the products are damaged due to improper installation or bad circumstances, our company could only provide charged services.

12. Frequently Asked Questions (FAQ)

Q: Does it work with 110V AC?
A: The smart switch supports a maximum voltage of AC90-250V, so it is compatible with 110V AC systems. However, please ensure the specific valve model you purchased is rated for 110V AC if applicable, as some models are specified for AC220V.
Q: If the valve is normally open, when I turn it ON, how long will it stay closed? Or will it remain closed until I turn it OFF?
A: The behavior depends on whether the valve is configured as "Normally Closed" or "Normally Open" (refer to Section 7.2). For a "Normally Open" valve, when powered on, ports B and C are open, and port A is closed. When powered off, ports A and B are open, and port C is closed. The valve will maintain its state (open or closed) as long as power is applied or removed, respectively, until a new command is issued or power status changes.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.