1. Introduction

The SZYTF WCS series Hall Current Sensor Module is designed for precise DC current detection and over-current protection. This versatile module offers two primary functionalities:

  1. Analog Signal Output: Provides an analog signal, conditioned by an operational amplifier, suitable for Analog-to-Digital (A/D) conversion in microcontrollers or data acquisition systems. This output is proportional to the measured current.
  2. Switch Signal Output: Features a configurable current limit value. When the detected current exceeds this preset threshold, the switch signal transitions from a low logic level to a high logic level, accompanied by an illuminated LED indicator. This allows for easy implementation of over-current detection and protection mechanisms.
Front view of the SZYTF WCS Hall Current Sensor Module
Figure 1: Front view of the SZYTF WCS Hall Current Sensor Module, showing pins and potentiometer.
Side view of the SZYTF WCS Hall Current Sensor Module
Figure 2: Side view of the SZYTF WCS Hall Current Sensor Module, highlighting the current sensing ring.
Angled view of the SZYTF WCS Hall Current Sensor Module
Figure 3: Angled view of the SZYTF WCS Hall Current Sensor Module, showing the compact design.
Top view of the SZYTF WCS Hall Current Sensor Module
Figure 4: Top view of the SZYTF WCS Hall Current Sensor Module, illustrating the current path and components.

2. Specifications

FeatureDetail
Brand NameSZYTF
TypeOptical-Electronics Sensor
Operating Voltage3-5V DC
Current Range (Model Dependent)WCS1600-100A, WCS1700-70A, WCS1700-200A, WCS1800-35A
Output TypeAnalog (Aout), Digital (Dout)
Adjustable ThresholdYes, via onboard potentiometer
IndicatorLED for switch signal
MaterialMixture
OriginMainland China
CustomizationYes (is_customized)
Package Dimensions (approx.)Length: 10cm, Width: 10cm, Height: 10cm
Package Weight (approx.)0.03 kg

3. Setup Instructions

Follow these steps to set up your WCS Hall Current Sensor Module:

  1. Power Connection:
    • Connect the Vcc pin to a 3-5V DC power supply.
    • Connect the GND pin to the ground of your power supply and control circuit.
  2. Current Path:
    • Route the wire carrying the current you wish to measure through the central hole of the Hall sensor component on the module. Ensure the wire passes cleanly through the opening.
  3. Output Connections:
    • Analog Output (Aout): Connect the Aout pin to an analog input (ADC) of your microcontroller (e.g., Arduino, ESP32) to read the current's analog value.
    • Digital Output (Dout): Connect the Dout pin to a digital input pin of your microcontroller for over-current detection.
  4. Threshold Adjustment:
    • The blue potentiometer on the module is used to set the threshold for the digital (Dout) output. Turn it clockwise to increase the threshold current and counter-clockwise to decrease it.
WCS1600-100A module showing pin labels and potentiometer
Figure 5: WCS1600-100A module highlighting pin labels (Vcc, Gnd, Aout, Dout) and the adjustable potentiometer.

4. Operation

Once the module is set up, you can begin monitoring current:

  1. Analog Current Measurement:
    • Read the voltage from the Aout pin using your microcontroller's ADC. This voltage will be proportional to the DC current flowing through the sensing hole.
    • Refer to the specific WCS sensor datasheet (e.g., WCS1600, WCS1700, WCS1800) for the voltage-to-current conversion ratio (mV/A) to accurately calculate the current.
  2. Digital Over-Current Detection:
    • Monitor the Dout pin. When the current through the sensor exceeds the threshold set by the potentiometer, the Dout pin will go HIGH, and the onboard LED will illuminate.
    • You can use this digital signal to trigger alarms, shut down circuits, or activate other protective measures in your system.

5. Maintenance

  • Keep the module clean and free from dust and moisture.
  • Avoid exposing the module to extreme temperatures or direct sunlight.
  • Ensure all connections are secure to prevent intermittent operation.
  • Do not apply voltage outside the specified 3-5V DC range to the Vcc pin.

6. Troubleshooting

  • No Output / Incorrect Readings:
    • Verify that the module is powered correctly (3-5V DC to Vcc and GND).
    • Check all wiring connections for continuity and correct polarity.
    • Ensure the current-carrying wire is properly routed through the sensor's hole.
    • For analog output, ensure your ADC is configured correctly and calibrated if necessary.
  • Digital Output (Dout) Not Triggering:
    • Confirm that the actual current exceeds the set threshold.
    • Adjust the potentiometer to lower the threshold if needed.
    • Check if the LED indicator on the module illuminates when the current is expected to exceed the threshold.
  • Module Overheating:
    • Ensure the current being measured does not exceed the maximum rating of your specific WCS model (e.g., 35A, 70A, 100A, 200A).
    • Verify that the power supply voltage is within the 3-5V DC range.

7. User Tips

  • When integrating the sensor, consider the physical dimensions of the current-carrying wire to ensure it fits through the sensor's opening.
  • For precise analog measurements, it is recommended to perform a calibration step in your software, mapping the ADC readings to actual current values based on known loads.
  • The digital output threshold can be fine-tuned for sensitive over-current protection in various applications.

8. Frequently Asked Questions (FAQ)

Q: What is the maximum frequency supported by the sensor?
A: The provided product information does not specify a maximum frequency for AC current measurement. These modules are primarily designed for DC current detection. For AC applications, consult the specific WCS sensor datasheet or contact technical support.
Q: What is the size of the hole in the sensor for the wire?
A: The sensor features a through-hole design for the current-carrying wire. While exact dimensions are not provided, it is designed to accommodate standard electrical wires for the specified current ranges. Visually inspect the module or refer to detailed mechanical drawings if precise dimensions are critical for your application.

9. Warranty and Support

For technical assistance, warranty claims, or further inquiries regarding your SZYTF WCS Hall Current Sensor Module, please contact the seller or manufacturer directly. Ensure you have your product model (e.g., WCS1600-100A) and any relevant purchase information available when seeking support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?