COMPTYCO Visual Fault Locator

Contents

COMPTYCO Visual Fault Locator User Manual

Model: Visual Fault Locator (10/30/50/60/80mW variants)

Your essential tool for fiber optic cable testing and fault location.

1. Product Overview

The COMPTYCO Visual Fault Locator (VFL) is a robust and efficient tool designed for identifying breaks, bends, and poor connections in fiber optic cables. It emits a powerful red laser light that allows for visual tracing of fiber paths and precise location of faults. With its durable metal construction and support for multiple connector types, it is an indispensable device for FTTH (Fiber To The Home) installations and maintenance.

COMPTYCO Visual Fault Locator with key features
Figure 1: COMPTYCO Visual Fault Locator highlighting breakpoint location, strong light source, and multiple connector support.

Key Features:

  • Breakpoint Location: Easily identifies breaks and faults in fiber optic cables.
  • Strong Light Source: Emits a powerful red laser for clear visibility over long distances.
  • Multiple Connector Support: Standard 2.5mm interface compatible with SC, FC, and ST connectors. LC connectors are supported with an optional FC male to LC female adapter (purchased separately).
  • High Quality Pen Head: Ensures stable performance and efficient operation.
  • Durable Design: Metal fuselage is wear-resistant and fall-resistant, with an anti-slip handle for comfortable use.
  • Power Options: Available in 10mW, 30mW, 50mW, 60mW, and 80mW output power variants.
  • Replaceable Ceramic Core: Allows for extended product lifespan.

2. Product Structure

Familiarize yourself with the components of your Visual Fault Locator for proper handling and maintenance.

Diagram of Visual Fault Locator components
Figure 2: Exploded view showing the Metal battery cartridge, Protective cap, Battery cover, and Sliding cover switch.
  • Protective Cap: Covers the optical port when not in use to prevent dust and damage.
  • Sliding Cover Switch: Controls the power and operating mode (constant or flashing light).
  • Optical Output Port: Where the laser light is emitted.
  • Metal Battery Cartridge: Houses the batteries.
  • Battery Cover: Secures the batteries within the device.

3. Setup

3.1 Battery Installation

  1. Unscrew the battery cover from the bottom of the Visual Fault Locator.
  2. Insert two (2) No.5 alkaline batteries (AA batteries) into the metal battery cartridge, ensuring correct polarity (+/-).
  3. Screw the battery cover back on securely.

3.2 Connector Preparation

  1. Remove the protective cap from the VFL's optical output port.
  2. For SC, FC, or ST connectors, directly insert the fiber optic cable connector into the VFL's 2.5mm universal interface.
  3. For LC connectors, an FC male to LC female adapter (purchased separately) is required. Attach the adapter to the VFL, then insert the LC connector into the adapter.
Visual Fault Locator supporting various fiber optic connectors
Figure 3: Illustration of VFL compatibility with FC, SC, LC, and ST connectors. Note the LC adapter is optional.

Safety Warning: Never look directly into the optical output port or at the laser light. Direct exposure can cause severe eye damage. Always use appropriate eye protection.

Close-up of VFL pen head with safety warning
Figure 4: Close-up of the VFL pen head connected to a fiber, with a critical safety reminder to avoid direct eye exposure to the light source.

4. Operating Instructions

4.1 Powering On and Mode Selection

The Visual Fault Locator features a sliding cover switch for easy operation.

Visual Fault Locator with anti-slip handle and switch explanation
Figure 5: Anti-slip handle design and explanation of the sliding switch for constant ('Changliang') and flashing ('Flashing') modes.
  • To turn on the VFL and activate constant light mode (CW), slide the switch upwards to the "CW" position.
  • To activate flashing light mode (GLINT), slide the switch downwards to the "GLINT" position. This mode can be useful for easier fault identification in some scenarios.
  • To turn off the VFL, slide the switch to the middle "OFF" position.

4.2 Fault Location

  1. Connect the fiber optic cable to be tested to the VFL's optical output port (refer to Section 3.2).
  2. Turn on the VFL to either constant or flashing mode.
  3. Observe the fiber optic cable along its path. The red laser light will escape from any breaks, cracks, or poorly connected points, making the fault visible.
  4. For long-distance fibers, the VFL's high-performance light-emitting head ensures the red light can penetrate effectively, allowing for fault detection even over extended lengths.
Visual Fault Locator penetrating long distance optical fiber
Figure 6: The VFL emitting a strong red light, demonstrating its capability to penetrate long-distance optical fiber for fault detection.

5. Maintenance

5.1 Cleaning the Optical Port

To ensure accurate readings and optimal performance, keep the optical output port clean. Use a lint-free optical cleaning swab and optical-grade alcohol to gently clean the port. Avoid touching the port with bare hands.

5.2 Replacing the Ceramic Core

The ceramic core is a consumable part and can be replaced if damaged or worn. Replacement ceramic cores and metal heads can be purchased separately.

Replaceable ceramic core for Visual Fault Locator
Figure 7: Diagram showing the replaceable ceramic core and metal head. Note: Ceramic core is fragile and should be handled with care.

Important: The ceramic core is fragile. Take off the metal head when replacing and do not install or remove it by force to prevent damage.

5.3 Battery Replacement

When the light output becomes dim or the device fails to power on, replace the two (2) No.5 alkaline batteries (AA batteries) as described in Section 3.1.

5.4 Storage

Store the VFL in a dry place within the specified storage temperature range of -20°C to +70°C. Always replace the protective cap when not in use to protect the optical port from dust and debris.

6. Troubleshooting

  • No Light Output:
    • Check if the batteries are correctly installed and have sufficient charge. Replace if necessary.
    • Ensure the sliding switch is in either the "CW" or "GLINT" position.
  • Weak or Intermittent Light:
    • Replace the batteries with fresh ones.
    • Clean the optical output port and the fiber connector thoroughly.
  • Inaccurate Fault Location:
    • Ensure the fiber optic cable and VFL connector are clean and properly seated.
    • Verify that the correct adapter is used for LC connectors.
    • Check for any physical damage to the VFL's optical head or the fiber itself.

7. Specifications

Table of Visual Fault Locator product parameters
Figure 8: Detailed product parameters including dimensions and performance metrics.
ParameterValue
Product NameVisual Fault Locator
Output Optical Power>10mW (Available in 10/30/50/60/80mW variants)
Output Wavelength650nm ± 10nm
Fiber Optic Adapter2.5mm universal connector (SC/FC/ST compatible)
Connector TypeSC/FC/ST (LC with optional adapter)
Service Temperature0°C to +60°C
Storage Temperature-20°C to +70°C
Battery Type2 x No.5 alkaline batteries (AA)
Battery Life>13 hours
Dimensions (L x W x H)17.5 x 2 x 2 cm
Weight (Device)70g
Weight (with package)~110g
Power SourcePowered (Battery)
Wireless FunctionNo
High-concerned chemicalNone

8. User Tips

  • For optimal visibility of faults, especially in brightly lit environments, consider using the flashing light mode.
  • Always ensure the fiber end-face is clean before connecting to the VFL to prevent contamination of the VFL's optical port and ensure clear light transmission.
  • When testing long fiber runs, start from one end and systematically check sections to narrow down the fault location.
  • Keep spare batteries on hand, especially for extended use, as battery life can vary.
  • The compact size and lanyard make it easy to carry and prevent accidental drops during fieldwork.

9. Warranty & Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.