1. Introduction
The MESTEK Combustible Gas Detector is a portable device designed for detecting various combustible gases. It features a high-performance sensor, offering high sensitivity and fast response. The detector is equipped with an analog display, automatic power-off, and some models include temperature and humidity display, along with a flashlight function.
This instrument is ideal for applications such as gas pipeline leak detection, household gas prevention, oil and natural gas exploitation, tunnel and mine operations, and use in chemical, metallurgical, refining, and biochemical medicine industries.
Compliance: The design, production, and verification of this product comply with national regulation JJG693-2011 (for detectors of combustible gas).
Video: MESTEK Combustible Gas Detector Overview
2. Key Features
- Flexible hose suitable for various detecting conditions.
- Adjustable high or low sensitivity for accurate leak detection.
- Dual alarm system: sound, backlight, and screen analog bar display.
- Temperature and humidity display (model dependent).
- Flashlight lighting.
- USB-C charging (CGD02B only).
- High-precision sensor with fast response.
- Double injection molding for durability.
- PPM/%LEL concentration unit switching (CGD02B only).

Image: Key features of the CGD02B model.
3. Product Appearance and Components
The detector consists of the following main components:
- Flashlight: Provides illumination in dark environments.
- Sensor: High-performance sensor for gas detection.
- Flexible Hose: A 285mm lengthened flexible probe for reaching complex measurement areas.
- Display Screen: Shows readings, symbols, and alarm indicators.
- Power Switch: Turns the device on/off.
- High/Low Sensitivity Switchover (H/L): Adjusts detection sensitivity.
- Flashlight/Cancel Auto Power-off (APO): Short press for flashlight, long press to cancel auto power-off.
- ZERO Button: Resets the instrument.
- Sound On/Off / Celsius/Fahrenheit Switchover: Short press to toggle sound, long press to switch temperature units.

Image: Product appearance with probe and flexible hose.

Image: Product dimensions (165mm x 53mm).
4. Display Introduction
The display screen provides crucial information during operation. The layout varies slightly between models:
CGD02B Display Screen:

Image: CGD02B Display Screen Layout.
- Automatic shutdown symbol
- Battery undervoltage symbol
- ZERO clear indicator
- Analog display bar
- Digital display of gas concentration
- Unit of measurement (PPM/%LEL)
- HIGH alarm prompt
- Timing symbol
- Sound symbol
CGD01B Display Screen:

Image: CGD01B Display Screen Layout.
- Automatic shutdown symbol
- Battery undervoltage symbol
- ZERO clear symbol
- Analog display
- Sound symbol
- Timing symbol
5. Setup and Initial Checks
5.1. Battery Installation/Charging
For CGD01B:
This model uses 3 x AAA 1.5V batteries.
- Turn off the product.
- Unscrew the battery cover on the back of the tester.
- Remove the battery cover.
- Insert new AAA batteries, ensuring correct polarity.
- Close the battery cover and tighten the screws.
For CGD02B:
This model has a built-in 3.7V/18650 lithium battery (2000mAh) and supports USB Type-C charging.
- Connect the USB Type-C cable to the detector's charging port and to a 5V/1A USB power adapter.
- The battery indicator on the screen will show charging status.
- A full charge takes approximately 4 hours.

Image: USB Type-C charging for CGD02B.
5.2. Pre-measurement Precautions
- Initial Calibration: Upon startup, the instrument enters an automatic calibration mode for approximately 30 seconds. During this time, ensure the detector is placed in a normal gas environment or away from potential gas leaks to ensure accurate calibration.
- Battery Check: If the battery undervoltage symbol (a battery icon with a low charge indicator) is displayed on the screen, replace the AAA batteries (CGD01B) or charge the built-in battery (CGD02B) promptly to avoid inaccurate measurements.
- Functionality Test: Before using the detector for actual gas leak detection, perform a preliminary test using an unlit lighter. The detector should be able to detect the presence of combustible gas from the lighter. If it fails this test, do not proceed with environmental detection and arrange for repair.
6. Operating Instructions
- Power On: Press the power button (
). The screen will display "WAIT" and the analog bar will flash, indicating the 30-second automatic calibration process. The instrument is ready for use once the countdown ends. - Sensitivity Adjustment: Use the H/L button (
) to switch between high and low sensitivity. High sensitivity is the default setting. - Flashlight & Auto Power-off: Short press the APO button (
) to turn the flashlight on/off. Long press the APO button to cancel the automatic power-off function. - Zeroing: Press the ZERO button (
) to reset the instrument's reading. - Sound & Temperature Unit: Short press the sound button (
) to toggle the sound alarm on/off. Long press it to switch between Celsius and Fahrenheit temperature units. - Gas Concentration Unit Switching (CGD02B only): Press the PPM/%LEL button (
) to switch between PPM (parts per million) and %LEL (Lower Explosive Limit) measurement units. - Detection Procedure: Slowly move the detector's probe to the area where a gas leak is suspected. If a gas leak is detected, the instrument will emit an audible alarm, the backlight will turn red, and the screen will display "HIGH" (for CGD02B) or show an increasing analog bar. The white analog bar indicates the maximum leakage detected.

Image: Using the flexible hose for household gas stove detection.

Image: Gas water heater detection.

Image: Triple alarm (sound, backlight, screen display) in action.
7. Maintenance
Proper maintenance ensures the longevity and accuracy of your gas detector.
- Handling: Do not drop or strike the product.
- Disassembly: Disassembly of the detector is forbidden to prevent malfunctions and void warranty.
- Storage: For long-term storage, remove the batteries (CGD01B) to prevent leakage. Store the instrument away from high temperatures, moisture, corrosive gases, or objects.
- Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use abrasive cleaners or solvents.
8. Troubleshooting
If you encounter issues with your gas detector, refer to the following common problems and solutions:
- Inaccurate Readings / No Detection:
a. Ensure the device was calibrated in a clean air environment during startup.
b. Check battery level. If the battery undervoltage symbol is displayed, replace batteries (CGD01B) or recharge (CGD02B).
c. Perform the unlit lighter test to confirm sensor functionality. If it fails, the sensor may be faulty and require repair. - Device Does Not Power On:
a. Check battery installation and charge level. - Alarm Not Functioning:
a. Ensure the sound alarm is not muted (short press the sound button).
b. Verify that the gas concentration exceeds the alarm threshold.
If the problem persists after attempting these solutions, please contact customer support.
9. Technical Specifications

Image: Technical Parameter Comparison (CGD01B vs CGD02B).
| Parameter | CGD01B | CGD02B |
|---|---|---|
| Product Name | Combustible Gas Detector | |
| Detectable Gas | Natural gas, coal gas, liquefied petroleum gas | |
| Power Supply | 1.5V X 3 AAA | Built-in 18650/2000mAh/3.7V |
| Charging Interface | - | USB Type-C |
| Charging Time | - | About 4h |
| Measurement Accuracy | - | < ±5%LEL, < ±500PPM |
| Automatic Shutdown | About 5 minutes | About 10 minutes |
| Display | General analog display | Digital display + analog bar |
| Operating Current | 120mA | About 185mA |
| Weight | About 210g (With battery) | About 230g |
| Sampling Method | Diffusive | |
| Response Speed | 2 seconds | |
| Calibration Method | Automatic calibration after 30 seconds of startup | |
| Alarm Mode | Sound, backlight, screen display | |
| Warm-up Time | 30 seconds | |
| Gas Measuring Range | 50-10000PPM | 50-50000PPM / 0-100%LEL |
| Working Temperature | 0-50°C | |
| Operating Humidity | 0-70%RH | |
| Storage Environment | -10~50°C (5%~95%RH) | |
| Hose Length | 285mm | |
| Size | 165*53*34mm | |
10. User Tips
- Always ensure the detector is fully charged or has fresh batteries before critical use.
- Calibrate the device in a well-ventilated area free from gas to ensure accurate baseline readings.
- When searching for leaks, move the probe slowly to allow the sensor sufficient time to react and provide precise readings.
- Pay attention to both audible and visual alarms for comprehensive leak detection.
- Regularly check the flexible hose for any damage or blockages that might affect detection accuracy.
11. Warranty and Support
For detailed warranty information and customer support, please refer to the official product documentation or contact your retailer.
An electronic version of the user manual (PDF) is available for download: MESTEK Combustible Gas Detector User Manual (PDF).