SUSWE HE100/HE200 Series

Contents

Variable Frequency Drive (VFD) HE100/HE200 Series Instruction Manual

Model: HE100/HE200 Series | Brand: SUSWE

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the SUSWE HE100/HE200 Series Variable Frequency Drive (VFD). The VFD is designed to control the speed of AC motors by varying the frequency and voltage of the power supplied to the motor. Please read this manual thoroughly before attempting to install or operate the device.

2. Safety Information

WARNING: Risk of electrical shock. Read the user manual before operation. Wait at least 10 minutes after removing power before servicing to allow capacitors to discharge.

  • Ensure all wiring is performed by qualified personnel in accordance with local and national electrical codes.
  • Always disconnect power before making any connections or performing maintenance.
  • Do not operate the VFD with damaged cables or if the enclosure is open.
  • Ensure proper grounding of the VFD and the motor.
  • Keep the VFD away from moisture, direct sunlight, and corrosive environments.
  • Do not touch internal components immediately after power disconnection, as residual voltage may be present.
Front view of the VFD with safety warning
Front view of the VFD, showing the display and control panel, along with a critical safety warning regarding electrical shock and waiting 10 minutes after power removal before servicing.

3. Product Overview

The SUSWE HE100/HE200 series VFDs are economical variable frequency drives designed for motor speed control. They offer various input/output configurations to suit different applications.

Key Features:

  • Forward, reverse, start, and stop control via panel or external terminals.
  • Speed adjustment via panel potentiometer or external potentiometer.
  • Built-in brake unit for connecting brake resistance.
  • PID function for applications like constant pressure water supply.
  • Multi-stage run capability.
  • RS485 communication protocol for PLC integration.
  • Vector control for low frequency and high torque applications.
  • Overload protection.
  • Optional external control panel (not included).

Model Variations:

The VFDs are available in various power ratings and input/output voltage configurations:

  • 1.5KW - 7.5KW: 220V 1-phase input to 380V 3-phase output
  • 1.5KW - 7.5KW: 380V 3-phase input to 380V 3-phase output
  • 1.5KW - 2.2KW: 220V 1-phase input to 220V 1-phase output
VFD input/output configurations and CE certification
Diagram illustrating the various input and output voltage/phase configurations supported by the VFD, along with CE certification mark.

4. Specifications

General Specifications:

  • Output Current: 4A - 25A
  • Output Frequency: 0-500Hz
  • Output Power: 0.75KW - 7.5KW
  • Type: DC/AC Inverters
  • Weight: 1.1KGS - 2.8KGS
  • Output Type: Triple
  • Certification: CE
  • Communication Protocol: RS485 Modbus
  • Brake Unit: Built-in

Technical Data (HE200 Series Example):

HE200 series VFD technical data table
Technical data table for the HE200 series VFD, detailing rated voltage, frequency, output current, output power, and control characteristics.

Technical Data (HE100 Series Example):

HE100 series VFD technical data table
Technical data table for the HE100 series VFD, detailing power capacity, input current, output current, and adaptive motor HP for various models.

5. Installation and Wiring

Proper installation and wiring are critical for the safe and correct operation of the VFD. Refer to the diagrams below for terminal connections and dimensions.

Dimensions:

HE100 series VFD dimensions
Dimensions for HE100 Series VFDs (Plastic 2.2KW structure and 3.5KW structure) and external keyboard dimensions.
HE200 series VFD dimensions
Dimensions for HE200 Series VFDs (Inverter model HE200-T3-0R7G to HE200-T3-0110) including width, height, and depth.

Main Circuit Terminal Description:

HE100 series VFD main circuit terminal description
Main circuit terminal description for HE100 series, showing terminals R, S, T (Power input), P+, PB (Braking resistor), U, V, W (Inverter output).
HE200 series VFD main circuit terminal diagram
Main circuit terminal diagram for HE200 series, showing R, S, T (Power input), Earth terminal, P+, PB (Dynamic braking resistor connection), U, V, W (Motor terminals).

Control Circuit Terminal Diagram and Function Description:

HE100 series VFD control loop wiring diagram
Control loop wiring diagram for HE100 series, including connections for braking resistor, three-phase power, motor, analog inputs (AOV, AOI), digital inputs (DI1-DI4), RS485 communication, and relay output.
HE200 series VFD control circuit terminal diagram and function description
Control circuit terminal diagram and detailed function description for HE200 series, covering +10V, +24V, GND, analog inputs (AI1, AI2), digital inputs (X1-X5), RS485, and relay outputs (K2A-K2C).
HE200 series VFD basic operation wiring diagram
Basic operation wiring diagram for HE200 series, showing connections for three-phase power, MCCB, motor, braking resistor, 10V output, relay output, analog inputs (AI1, AI2), and digital inputs (X1-X4).

6. Operating Instructions

The VFD can be operated via its integrated control panel or external terminals. Familiarize yourself with the control panel layout and functions.

Control Panel Description:

HE200 series VFD keyboard description
Keyboard description for HE200 series, detailing display area, status indicator, program key, numeric modifier keys, run key, stop/reset key, and displacement key functions.
HE100 series VFD keyboard description
Keyboard description for HE100 series, detailing display area, status indicator, program key, numeric modifier keys, run key, stop/reset key, and displacement key functions.

Basic Operation:

  • Start/Stop: Use the RUN and STOP/RESET buttons on the panel, or configure external terminals for control.
  • Speed Adjustment: Adjust the frequency using the potentiometer on the panel or an external potentiometer connected to the analog input terminals.
  • Parameter Setting: Use the PRG (Program) key to enter parameter settings. Navigate using the arrow keys and confirm with ENTER. Refer to the full user manual for detailed parameter descriptions and programming instructions.

7. Maintenance

Regular maintenance ensures the longevity and reliable operation of your VFD.

  • Cleaning: Keep the VFD clean and free from dust and debris. Ensure ventilation openings are not obstructed.
  • Inspection: Periodically check all wiring connections for tightness and signs of wear or damage.
  • Cooling: Ensure adequate airflow around the VFD for proper cooling.
  • Power Disconnection: Always disconnect the main power supply before performing any maintenance or inspection. Wait at least 10 minutes after power removal to allow internal capacitors to discharge completely before touching any components.

8. Troubleshooting

This section provides general guidance for common issues. For specific error codes or complex problems, consult the detailed user manual or contact technical support.

  • No Power/Display: Check input power connections, fuses, and circuit breakers.
  • Motor Not Running: Verify VFD status (RUN/STOP), check motor wiring, ensure correct parameter settings (e.g., frequency, voltage, motor type).
  • Overload Error: Check motor load, ensure VFD capacity matches motor requirements, and verify motor parameters in VFD settings.
  • Overvoltage/Undervoltage Error: Check input power supply stability.
  • Overheat Error: Ensure proper ventilation and ambient temperature. Clean any dust from cooling fins.

9. User Tips

  • VFD Sizing: When selecting a VFD, especially for 220V to 380V conversion, it is recommended to choose a VFD with a higher power rating than your motor. For light loads, select one grade larger (e.g., for a 1.5KW motor, choose a 2.2KW VFD). For heavy loads, consider multiplying the motor's power by two (e.g., for a 2.2KW motor, choose a 5.5KW VFD). This provides sufficient margin due to the voltage conversion.
  • Programming: Many users inquire about programming. The VFD offers extensive parameter settings. It is crucial to refer to the detailed English manual for specific programming steps to configure functions like PID, multi-stage run, and communication protocols.
  • Input/Output Configuration: Ensure your VFD model matches your power supply (e.g., 220V single-phase) and motor requirements (e.g., 380V three-phase).

10. Frequently Asked Questions (FAQ)

Q: Can this VFD convert 220V single-phase input to 380V three-phase output?
A: Yes, specific models in the HE100/HE200 series are designed for 220V 1-phase input to 380V 3-phase output. Please verify the model specifications before purchase.
Q: Is an English instruction manual available?
A: Yes, an English manual is available. It is highly recommended to obtain and review the full English manual for detailed installation, wiring, and programming instructions.
Q: Can the output voltage be configured to 220V?
A: Some models support 220V 1-phase input to 220V 1-phase output. For other configurations, refer to the specific model's technical data and programming parameters.
Q: How do I program the VFD?
A: Programming involves setting various parameters using the control panel. Detailed steps and parameter codes are provided in the comprehensive user manual. It is essential to follow these instructions carefully.
Q: Does it have soft start and reverse functions?
A: Yes, the VFD supports soft start and has forward/reverse control capabilities, which can be operated via the panel or external terminals.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized dealer. Keep your purchase records for reference.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.