1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the SUSWE HE100/HE200 Series Variable Frequency Drive (VFD). The VFD is designed to control the speed of AC motors by varying the frequency and voltage of the power supplied to the motor. Please read this manual thoroughly before attempting to install or operate the device.
2. Safety Information
WARNING: Risk of electrical shock. Read the user manual before operation. Wait at least 10 minutes after removing power before servicing to allow capacitors to discharge.
- Ensure all wiring is performed by qualified personnel in accordance with local and national electrical codes.
- Always disconnect power before making any connections or performing maintenance.
- Do not operate the VFD with damaged cables or if the enclosure is open.
- Ensure proper grounding of the VFD and the motor.
- Keep the VFD away from moisture, direct sunlight, and corrosive environments.
- Do not touch internal components immediately after power disconnection, as residual voltage may be present.
3. Product Overview
The SUSWE HE100/HE200 series VFDs are economical variable frequency drives designed for motor speed control. They offer various input/output configurations to suit different applications.
Key Features:
- Forward, reverse, start, and stop control via panel or external terminals.
- Speed adjustment via panel potentiometer or external potentiometer.
- Built-in brake unit for connecting brake resistance.
- PID function for applications like constant pressure water supply.
- Multi-stage run capability.
- RS485 communication protocol for PLC integration.
- Vector control for low frequency and high torque applications.
- Overload protection.
- Optional external control panel (not included).
Model Variations:
The VFDs are available in various power ratings and input/output voltage configurations:
- 1.5KW - 7.5KW: 220V 1-phase input to 380V 3-phase output
- 1.5KW - 7.5KW: 380V 3-phase input to 380V 3-phase output
- 1.5KW - 2.2KW: 220V 1-phase input to 220V 1-phase output
4. Specifications
General Specifications:
- Output Current: 4A - 25A
- Output Frequency: 0-500Hz
- Output Power: 0.75KW - 7.5KW
- Type: DC/AC Inverters
- Weight: 1.1KGS - 2.8KGS
- Output Type: Triple
- Certification: CE
- Communication Protocol: RS485 Modbus
- Brake Unit: Built-in
Technical Data (HE200 Series Example):
Technical Data (HE100 Series Example):
5. Installation and Wiring
Proper installation and wiring are critical for the safe and correct operation of the VFD. Refer to the diagrams below for terminal connections and dimensions.
Dimensions:
Main Circuit Terminal Description:
Control Circuit Terminal Diagram and Function Description:
6. Operating Instructions
The VFD can be operated via its integrated control panel or external terminals. Familiarize yourself with the control panel layout and functions.
Control Panel Description:
Basic Operation:
- Start/Stop: Use the RUN and STOP/RESET buttons on the panel, or configure external terminals for control.
- Speed Adjustment: Adjust the frequency using the potentiometer on the panel or an external potentiometer connected to the analog input terminals.
- Parameter Setting: Use the PRG (Program) key to enter parameter settings. Navigate using the arrow keys and confirm with ENTER. Refer to the full user manual for detailed parameter descriptions and programming instructions.
7. Maintenance
Regular maintenance ensures the longevity and reliable operation of your VFD.
- Cleaning: Keep the VFD clean and free from dust and debris. Ensure ventilation openings are not obstructed.
- Inspection: Periodically check all wiring connections for tightness and signs of wear or damage.
- Cooling: Ensure adequate airflow around the VFD for proper cooling.
- Power Disconnection: Always disconnect the main power supply before performing any maintenance or inspection. Wait at least 10 minutes after power removal to allow internal capacitors to discharge completely before touching any components.
8. Troubleshooting
This section provides general guidance for common issues. For specific error codes or complex problems, consult the detailed user manual or contact technical support.
- No Power/Display: Check input power connections, fuses, and circuit breakers.
- Motor Not Running: Verify VFD status (RUN/STOP), check motor wiring, ensure correct parameter settings (e.g., frequency, voltage, motor type).
- Overload Error: Check motor load, ensure VFD capacity matches motor requirements, and verify motor parameters in VFD settings.
- Overvoltage/Undervoltage Error: Check input power supply stability.
- Overheat Error: Ensure proper ventilation and ambient temperature. Clean any dust from cooling fins.
9. User Tips
- VFD Sizing: When selecting a VFD, especially for 220V to 380V conversion, it is recommended to choose a VFD with a higher power rating than your motor. For light loads, select one grade larger (e.g., for a 1.5KW motor, choose a 2.2KW VFD). For heavy loads, consider multiplying the motor's power by two (e.g., for a 2.2KW motor, choose a 5.5KW VFD). This provides sufficient margin due to the voltage conversion.
- Programming: Many users inquire about programming. The VFD offers extensive parameter settings. It is crucial to refer to the detailed English manual for specific programming steps to configure functions like PID, multi-stage run, and communication protocols.
- Input/Output Configuration: Ensure your VFD model matches your power supply (e.g., 220V single-phase) and motor requirements (e.g., 380V three-phase).
10. Frequently Asked Questions (FAQ)
- Q: Can this VFD convert 220V single-phase input to 380V three-phase output?
- A: Yes, specific models in the HE100/HE200 series are designed for 220V 1-phase input to 380V 3-phase output. Please verify the model specifications before purchase.
- Q: Is an English instruction manual available?
- A: Yes, an English manual is available. It is highly recommended to obtain and review the full English manual for detailed installation, wiring, and programming instructions.
- Q: Can the output voltage be configured to 220V?
- A: Some models support 220V 1-phase input to 220V 1-phase output. For other configurations, refer to the specific model's technical data and programming parameters.
- Q: How do I program the VFD?
- A: Programming involves setting various parameters using the control panel. Detailed steps and parameter codes are provided in the comprehensive user manual. It is essential to follow these instructions carefully.
- Q: Does it have soft start and reverse functions?
- A: Yes, the VFD supports soft start and has forward/reverse control capabilities, which can be operated via the panel or external terminals.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized dealer. Keep your purchase records for reference.