1. Introduction
This controller is specifically designed for solar energy applications, featuring an electronically driven DC brushless motor. It boasts high efficiency with Maximum Power Point Tracking (MPPT) functionality, automatically adjusting motor speed based on sunlight intensity. The system automatically starts when sunlight is available and shuts down when there is no sunlight. It is suitable for deep well pumping, agricultural irrigation, and domestic water intake.
Key features include a high-quality aluminum alloy shell for temperature resistance, an LED display for viewing power, current, voltage, and speed, and robust wiring ports with high insulation voltage, resistant to vibration.
A notable feature is the automatic pump stop when water is absent, eliminating the need for a liquid level switch in the well (a liquid level switch is required for water towers).

2. Specifications
| Attribute | Value |
|---|---|
| Product Name | Photovoltaic water pump controller/solar water pump controller |
| Material | Aluminum Alloy |
| Application | Charger Controller, Voltage Controller |
| Working Fluid | Water |
| Drive Mode | DC Brushless |
| Transmission Medium | Water pump |
| Rated Voltage Options | 24V, 48V, 72V, 96V, 110V |
| Maximum Current | 16A |
| Certification | CE |
| Is Smart Device | No |
| is_customized | Yes |
| Weight | 1.8kg |
2.1. Performance Parameters by Model
| Model | DC 24V 48V | DC 72V | DC 96-110V |
|---|---|---|---|
| Rate Voltage | 24V - 48V | 72V | 96-110V |
| Rated Input Power (W) | 450W (24V), 900W (48V) | 1400W | 1800W (96V), 2000W (110V) |
| Max Input Current (A) | 16A | 16A | 16A |
| Max Input Voltage (V) | 63V (24V), 100V (48V) | 150V | 200V |
| Min Input Voltage (V) | 20V (24V), 30V (48V) | 50V | 60V |
| MPPT Voltage (V) | 24V-36V (24V), 48V-72V (48V) | 72V-108V | 96V-144V |
| Working Condition (°C) | -15 to 60 degrees | -15 to 60 degrees | -15 to 60 degrees |
Important: Users must use an instrument to measure the open circuit voltage of the solar panel before starting, or use knowledge of series and parallel connections to calculate it. The open circuit voltage of the solar panel must not exceed the maximum input voltage of the controller, otherwise it will cause irreversible damage.

3. Setup and Installation
3.1. Solar Panel Connection Information
Solar panels can be connected in series, parallel, or a combination of both to achieve the desired voltage and current for the pump controller.
- Series Connection: When panels are connected in series, the voltage adds up, while the current remains unchanged.
- Parallel Connection: When panels are connected in parallel, the current adds up, while the voltage remains unchanged.

3.2. Wiring Diagram
The controller features clearly labeled connection terminals for solar panels, pump motor, and water level sensors. Ensure all connections are secure and correctly polarized.

Warning: Do not reverse the positive and negative of the power connection, otherwise the system will not work.
3.3. Pre-Installation Inspection
- Before use, check whether the electric pump is intact, and inspect for any looseness, seepage, oil leakage at each connection, or accidental damage (e.g., to the cable line).
- Use a megohmmeter to measure the insulation resistance of the pump; it should be greater than 2MΩ.
- If the cable supplied with the pump is not long enough and needs extension, the diameter of the added wire must be larger than the original one. All joints must be well sealed with waterproof tape.
- Before formal use, connect the pump to the power supply and perform a startup check. The pump must always be submerged in water when running (dry running is strictly forbidden). If the pump runs incorrectly (no water flowing out), reconnect any two of the power cables.
- When installing the pump, use ropes at the hole ring for lifting. Do not lift the pump by its cable.
- The pump should be installed at least 1 meter from the bottom to prevent mud and sand from being sucked in, which could damage the mechanical seal and impeller.
4. Operation
4.1. Operation Panel Overview

4.1.1. LED Indicators
- "V" light: Indicates the screen is displaying "input voltage".
- "RPM" light: Indicates the screen is displaying "motor speed".
- "A" light: Indicates the screen is displaying "input current".
- "W" light: Indicates the screen is displaying "input power".
- "Tank" light: Illuminates when the tank is full.
- "Well" light: Illuminates when there is no water in the water source.
- "MPPT" light: Illuminates when there is solar input power.
- "Power" light: On when the pump is running, flashing when the pump stops.
4.1.2. Key Operations
| Button | Function |
|---|---|
| Set | Manufacturer operating only. |
| Enter | Manufacturer operating only. |
| Up (▲) | Rotation speed setting: each press increases speed by one gear. In fault state, ON/OFF the fault display. |
| Down (▼) | Rotation speed setting: each press decreases speed by one gear. |
| Switch | In running status, switches display mode (Voltage (V) -> Speed (RPM) -> Current (A) -> Power (W) cyclically). |
| ON/OFF | Starts/stops the pump. |
4.2. Pump Operation Modes
The pump detects the power supply mode (DC battery or PV solar) each time it starts. The detection time is 10 seconds. During this process, setting speed is invalid.
4.2.1. Starting the Pump
- Power-on Start: When the system is powered on, the pump will start immediately without detecting a tank shortage signal (no shutdown conditions).
- Start via Key: If the system is off (digital tube displays OFF), press the ON/OFF key to switch to the ON state. The pump will start immediately without detecting a tank shortage signal.
- Start when Water Tank is Low: If the system is on but the pump is off, and the water tank shortage switch is closed (TL signal terminal and COM terminal are short-circuited), the pump will start immediately.
4.2.2. Stopping the Pump
- Shutdown by Float Signal (Tank Full): If the pump is running and the water tank becomes full (TH signal terminal COM are short-circuited, TANK light on), the pump will stop immediately and restart in 20 minutes.
- Shutdown by Float Signal (Well Dry): If the pump is running and there is a water shortage in the well (WEL signal terminal and COM are short-circuited, WELL light on), the pump will stop immediately and restart in 15 minutes.
- Shutdown by Dry Pumping: If the pump runs for some time with current power less than the set power at the current speed for 20 seconds, it will stop immediately (error P48). Automatic recovery after 30 minutes.
- Shutdown by Pressing Key: When the pump is running, press the ON/OFF key to stop the pump.
4.2.3. Pump Running Modes (DC/PV)
- DC (Battery) Mode:
- Speed is adjustable from 1000-6000 RPM. Default is 6000 RPM. Use Up/Down keys to adjust.
- To prevent battery over-discharge, the pump will stop if the voltage drops below the corresponding protection voltage (e.g., 20V for 24V system, 40V for 48V system, etc.).
- PV (Solar) Mode:
- Speed setting is similar to DC mode, with a 6000 RPM maximum limit.
- The running speed is determined by the current solar panel power. The system tracks the Maximum Power Point (MPPT) in real-time.
- As sunlight intensity increases, the output power of the solar panel increases, and the pump speed increases (and vice versa).
- The MPPT indicator flashes; faster flashing indicates closer to maximum operating point.
- If solar power is insufficient, the pump speed will decrease. If speed drops to 600 RPM, the pump will stop (error P46) after 3 seconds.
- If solar power is insufficient to maintain starting or running, the output voltage of the solar panel will drop rapidly. If it drops to the minimum voltage for 10 seconds, error "PL" will occur. The pump will attempt to start 5 times; if it fails, it will restart after 30 minutes.
4.3. Anti-Reverse Function
If the P+ and P- terminals are connected in reverse, the controller will continuously alarm.
5. Maintenance
- After 3000 hours of operation, the wearing parts (bearings, sealing rings, mechanical seals, etc.) must be replaced to prevent greater damage.
- If the pump will not be used for an extended period, it should be cleaned, wiped dry, and stored in a ventilated, dry place.
6. Troubleshooting
| Error Code | Error | Possible Causes | Recovery |
|---|---|---|---|
| P0 | Hardware overcurrent |
| Automatic recovery after 60s. |
| P43 | Phase protection | Short circuit in U, V, W 3-phase wiring. | Automatic recovery after 60s. |
| P46 | Low Speed protection |
| Automatic recovery after 30s. |
| P48 | Running dry |
| Automatic recovery after 30s or restart. |
| P49 | Software overcurrent |
| Automatic recovery after 30s. |
| P50 | Low power | Input voltage too low (refer to electrical characteristics for correct distribution). | Automatic recovery after 5s when input voltage resumes. |
| P51 | Over power | Input voltage too high (refer to electrical characteristics for correct distribution). | Automatic recovery after 5s when input voltage resumes. |
| P60 | High Temperature | MCU temperature in controller over 90°C. | Automatic recovery after 5s. |
| E8 | Current sampling failure | Switch off power, restart after 30s. | Recovery when restart. |
| PL | Low input power |
| Automatic recovery after 30s (first 5 times), then after 30mins. |
| Continuous rumbling | Input wire is reversed | Reconnect P+ and P-. | Recovery when restart. |
7. User Tips
- Ensure your water pump's magnetic steel is compatible (3 pairs of poles) for normal operation with this controller. If unsure, consult customer service with your pump's parameters.
- Always verify the open circuit voltage of your solar panels before connecting to avoid damage to the controller.
- For optimal performance, ensure proper sizing and connection of solar panels (series/parallel) to match the controller's voltage and power requirements.
8. Frequently Asked Questions (FAQ)
- Q: In what scenarios can I use this controller?
- A: You can use it in various solar water pump applications, including deep well pumping, agricultural irrigation, and domestic water intake.
- Q: What are the functions of this controller?
- A: It can function as a charger controller and a voltage controller.
- Q: Which category does this controller belong to?
- A: It belongs to the solar water pump control category.
- Q: Can you tell me more about its highlights?
- A: Some of its highlights include CE certification and customization options.
- Q: What are the benefits of using this controller?
- A: Using this controller ensures efficient charging and effective voltage control for your solar water pump system.
- Q: What is the voltage of it?
- A: The voltage can be 24V, 48V, 72V, or 96V.
- Q: How to check if my water pump can be used with this controller?
- A: Please check the magnetic steel of your water pump. If it has 3 pairs of poles, the controller can be used normally. If you are unsure, please send the parameters of your water pump to customer service for confirmation.
9. Warranty and Support
For any issues not covered in this manual or for further assistance, please contact HXCONTROLLER Official Store customer support. Refer to the official product page for warranty details and contact information.
A PDF version of the user manual is available for download: User Manual (PDF)