HXCONTROLLER MPPT Solar Water Pump Controller

Contents

HXCONTROLLER MPPT Solar Water Pump Controller User Manual

Model: MPPT Solar Water Pump Controller

1. Introduction

This controller is specially designed for solar energy, electronically driven DC brushless motors, offering high efficiency with MPPT (Maximum Power Point Tracking) function. It features automatic frequency conversion according to sunlight intensity, adjusting the motor speed, and automatic startup when sunlight is available, with automatic shutdown when there is no sunlight.

The solar water pump controller is suitable for applications such as deep well pumping, agricultural irrigation, and domestic water intake.

Key Features:

  • High Quality Shell: Designed for high temperature resistance.
  • LED Display: Provides real-time viewing of power, current, voltage, speed, and other parameters.
  • Wiring Port: Features high insulation voltage and resistance to vibration.
  • Automatic Water Stop: The system automatically stops the pump when there is no water in the well (a liquid level switch is required for water tower applications).
Front view of the HXCONTROLLER MPPT Solar Water Pump Controller

Figure 1: Front view of the MPPT Solar Water Pump Controller

Video 1: Demonstration of the solar water pump system in operation.

2. Specifications

Product Parameters:

  • Product Name: Photovoltaic water pump controller / Solar water pump controller
  • Material: Aluminum alloy
  • Working Fluid: Water
  • Use: Water pump controller
  • Drive Mode: DC brushless
  • Transmission Medium: Water pump
  • Voltage Options: 24V/48V/72V/96V/110V
  • Weight: 1.8kg

Performance Table:

MPPT Solar Water Pump Controller Specifications
ModelDC 24V 48VDC 72VDC 96-110V
Rate Voltage24V -48V72V96-110V
Rated Input Power(W)450W(24V) 900W(48V)1400W1800W(96V) 2000W(110V)
Max input current (A)16A16A16A
Max input voltage (V)63V(24V) 100V(48V)150V200V
Min input voltage (V)20V(24V) 30V(48V)50V60V
MPPT voltage (V)24V-36V(24V),48V-72V(48V)72V-108V96V-144V
Working condition (°C)minis 15-60degreeminis 15-60degreeminis 15-60degree

Dimensions:

Dimensions of the MPPT Solar Water Pump Controller: 24.5cm x 19.2cm x 9.7cm

Figure 2: Controller Dimensions (Length: 24.5cm, Width: 19.2cm, Height: 9.7cm)

3. Setup and Installation

3.1 Solar Panel Connection Information

Solar panels can be connected in series, parallel, or a combination of both to achieve the desired voltage and current. When connecting panels in series, the voltage adds up while the current remains unchanged. When connecting panels in parallel, the current adds up while the voltage remains unchanged.

Diagram showing solar panel series, parallel, and series-parallel connection configurations

Figure 3: Solar Panel Connection Configurations

3.2 Wiring Diagram and Connection Terminals

The controller features clearly labeled connection terminals for solar panels, pump motor, and water level sensors.

Detailed diagram of the controller's connection terminals: PE, P+, P-, W, V, U, TL, TH, WEL, COM

Figure 4: Connection Terminal Description

System connection diagram showing solar panel, DC air switch, controller, pump motor, and water level sensors

Figure 5: System Connection Diagram

3.3 Pre-installation Inspection and Important Notes

  1. Before use, check whether the electric pump is intact, free from looseness, seepage, or oil leakage at each connection. Inspect for any accidental damage to the cable line. Use a megohmmeter to measure the insulation resistance of the pump; it should be >2M.
  2. If the cable supplied with the pump is not long enough and needs to be extended, the diameter of the added wire must be larger than the original one. All joints must be well sealed with waterproof tape.
  3. Before formal use, connect the pump to the power supply and perform a startup check. The pump should always be submerged in water when running (dry running is strictly forbidden). If the pump runs incorrectly (no water flowing out), reconnect any two of the power cables.
  4. When installing the pump, use ropes at the hole ring for lifting. Do not lift by the pump's cable. The pump should be installed at least 1 meter from the bottom to prevent mud and sand from being sucked in, which could damage the mechanical seal and impeller.

Important Warning: You must use an instrument to measure the open circuit voltage of the solar panel before starting, or calculate it using knowledge of series and parallel connections. The open circuit voltage of the solar panel must NOT exceed the maximum input voltage of the controller, otherwise, it will cause irreversible damage.

4. Operation

4.1 Operation Panel

Controller operation panel with LED indicators and control buttons

Figure 6: Controller Operation Panel

4.2 LED Indicators

  • "V" light: On when the screen displays input voltage.
  • "RPM" light: On when the screen displays motor speed.
  • "A" light: On when the screen displays input current.
  • "W" light: On when the screen displays input power.
  • "Tank" light: On when the water tank is full.
  • "Well" light: On when there is no water in the water source.
  • "MPPT" light: On when there is solar input power.
  • "Power" light: On when the pump is running; flashes when the pump stops.

4.3 Key Operation

Controller Key Functions
ButtonFunction
SetManufacturer operating only.
EnterManufacturer operating only.
Up (▲)
  • Rotation speed setting: Each press increases speed by one gear.
  • In fault state: ON/OFF the fault display.
Down (▼)Rotation speed setting: Each press decreases speed by one gear.
Switch (ON/OFF)
  • In running status: Switches display mode (Voltage -> Speed -> Current -> Power cyclically).
  • Starts/stops the pump.

4.4 Pump Operation Modes

4.4.1 Pump Start

  • Power-on Start: When the power is turned on, the system starts by default. The pump will start immediately without detecting a tank shortage signal (if no shutdown conditions are met).
  • Key Start: If the system is off (digital tube displays OFF), pressing the ON/OFF key switches it to the on state. The pump will start immediately without detecting a shortage signal.
  • Start when Water Tank is Short of Water: If the system is on and the pump is in a shutdown state, and the water tank shortage switch is closed (TL signal terminal and COM terminal are short-circuited), the pump will start immediately.

4.4.2 Pump Shutdown

  • Shutdown by Float Signal:
    • If the pump is running and the water tank is full (TH signal terminal COM are short-circuited, TANK light on), the pump stops immediately and restarts in 20 minutes.
    • If the water pump is running and there is a water shortage (WEL signal terminal and COM are short-circuited, WELL light on), the pump stops immediately and restarts in 15 minutes.
  • Shutdown by Dry Pumping: If the pump runs for some time, and the current power is less than the set power at the current speed for 20s, the pump stops immediately, displays error P48, and automatically recovers after 30 minutes.
  • Shutdown by Pressing the Key: When the pump is running, press the ON/OFF key to stop the pump.

4.5 Pump Running

The pump detects the power supply mode (DC battery or PV solar) each time it starts. The detection time is 10s, after which it switches to the corresponding mode. During the detection process, setting speed is invalid.

4.5.1 DC (Battery) Mode

In DC (battery) mode, the pump speed is adjustable from 1000-6000RPM. The default setting speed is 6000RPM. Pressing the Up or Down key adjusts the speed by one gear.

The DC (battery) power supply voltage will drop as the pump runs. To prevent battery over-discharge, the pump will stop working when the voltage drops below the corresponding protection voltage:

ModelProtection Voltage (V)
24V20
48V40
72V60
96V80

4.5.2 PV Mode

Speed setting in PV mode is similar to DC mode, with the maximum speed limit of 6000RPM. The pump's running speed is also determined by the current solar panel power. The system tracks the maximum power of the solar panel (MPPT) in real-time. As sunlight intensity increases, the solar panel's output power increases, leading to an increase in pump speed, and vice versa.

In PV mode, the MPPT indicator flashes. A faster flashing frequency indicates the current work point is closer to the maximum operating point. If the flashing frequency is slower or does not flash, the current is tracking the maximum power point.

If solar power is insufficient, the pump speed will decrease. When the speed drops to 600rpm, the pump will stop and show error P46 within 3 seconds.

If the system's output voltage drops rapidly due to insufficient solar power, and it remains at the minimum voltage for 10 seconds, it will display error "PL". The pump will attempt to restart 5 times; if it fails, it will try again after 30 minutes.

4.6 Anti-Reverse Function

If the P+ and P- terminals are connected in reverse, the controller will continuously alarm.

5. Maintenance

  • After the pump has been running for 3000 hours, wearing parts such as bearings, sealing rings, and mechanical seals must be replaced. Failure to do so may lead to greater damage.
  • If the pump will not be used for an extended period, it should be cleaned, wiped dry, and stored in a ventilated and dry place.

6. Troubleshooting

Error Codes and Solutions
Error CodeErrorPossible CausesRecovery
P0Hardware overcurrent
  • The controller and pump are not matched; match a suitable pump.
  • There's a short circuit in U, V, W 3-phase; rewire U, V, W correctly.
Automatic recovery after 60s
P43Phase protectionThere's a short circuit in U, V, W 3-phase; rewire U, V, W correctly.Automatic recovery after 60s
P46Low Speed protection
  • The controller and pump are not matched; match a suitable pump.
  • The extension cable is too long; replace it with a thicker one.
  • Input power is too low; increase the input power.
  • The motor is blocked; clean up the pump.
Automatic recovery after 30s
P49Software overcurrent
  • The controller and pump are not matched; match a suitable pump.
  • There's a short circuit in U, V, W 3-phase; rewire U, V, W correctly.
Automatic recovery after 30s
P50Low powerInput voltage is too low; refer to the electrical characteristic of this model, electricity distribution correctly.Automatic recovery after 5s when the input voltage resumes.
P51Over powerInput voltage is too high; refer to the electrical characteristic of this model, electricity distribution correctly.Automatic recovery after 5s when the input voltage resumes.
P48Running dry
  • There's air remaining in the pump; cut off the power, reconnect, and start the pump after 30s.
  • There's no water in the water source; restart the pump when there's enough water.
Automatic recovery after 30s or restart.
P60High TemperatureThe temperature of MCU in the controller is over 90°C.Automatic recovery after 5s.
E8Current sampling failureSwitch off the power, restart after 30s.Recovery when restarted.
PLLow input power
  • NO sunshine; restart when there's enough sunshine.
  • Solar panels used are not suitable; refer to recommendations, select suitable solar panel.
First 5 times, automatic recovery after 30s; then automatic recovery after 30mins later.
Continuous rumblingInput wire is reversedReconnect the P+ and P-.Recovery when restarted.

7. User Tips

  • Pump Compatibility: Before connecting your water pump, check if its magnetic steel is 3 pairs of poles. If you are unsure about compatibility, please provide the water pump parameters to the seller for confirmation.
  • Water Level Management: The controller automatically stops the pump when there is no water in the well. For water tower applications, a separate liquid level switch is required to manage water levels.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller directly. Keep your purchase records for reference.

A detailed user manual in PDF format is available for download: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.