yieryi PH-W218EU

Contents

PH-W218EU WiFi Tuya Smart 8-in-1 Water Quality Tester

User Manual

Brand: yieryi | Model: PH-W218EU

1. Introduction

The yieryi PH-W218EU is an advanced 8-in-1 WiFi-enabled water quality tester designed for continuous monitoring of various water parameters. This smart device integrates pH, EC, TDS (ppm), ORP, CF, Salinity, S.G., and Temperature measurements into a single unit, providing real-time data and logging capabilities through the Tuya Smart APP. It is ideal for a wide range of applications including aquariums, hydroponics systems, swimming pools, and other water sources where precise water quality management is crucial.

yieryi PH-W218EU 8-in-1 WiFi Water Quality Tester with probes and smartphone app interface
Figure 1: PH-W218EU 8-in-1 WiFi Water Quality Tester overview with probes and smartphone app interface.

2. Key Features

  • 8-in-1 Water Quality Tester: Simultaneously measures pH, EC, TDS (ppm), ORP, CF, Salinity, S.G., and Temperature. Measurement units can be switched on the screen with a single click.
  • WiFi Tuya APP Connectivity: Enables accurate real-time WiFi data transmission and clear measured values, allowing for easy saving, management, and sharing of test data without data loss.
  • Data Logger: Data is automatically stored and saved for up to 30 days. Data is transmitted every 15 seconds, and data curve graphs are provided for analysis. Export data to Excel files on your phone or PC.
  • LCD Backlight Display: Multi-parameter display for clear reading, supporting night monitoring.
  • Wide Applications: Suitable for water sources, aquariums, hydroponics, laboratories, spas, swimming pools, fish tanks, koi ponds, and other water systems.

3. Packing List

Ensure all the following items are included in your package:

  • 1 x PH-W218EU Monitor
  • 1 x pH Probe
  • 1 x ORP Probe
  • 1 x PPM/EC/Salt/S.G./CF Probe
  • 1 x Temperature Probe
  • 1 x Power Adapter/Charger
  • 1 x English User Manual (PDF version also available: Download PDF)
  • 2 x Suction Cups
  • 1 x Clip
Contents of the PH-W218EU package including the monitor, probes, power adapter, and accessories
Figure 2: Package contents of the PH-W218EU water quality tester.

4. Specifications

ParameterRangeResolutionAccuracy
pH0.00 - 14.00 pH0.01 pH±0.03 pH
ORP-2000 mV - +2000 mV1 mV±5 mV
EC0 - 19000 us/cm, 0 - 199.0 ms/cm1 us/cm (<1999 us/cm), 10 us/cm (>1999 us/cm), 0.1 ms/cm±2% F.S
TDS0 - 19990 ppm, 0 - 199.0 ppt1 ppm (<1999 ppm), 10 ppm (>1999 ppm), 0.1 ppt±2% F.S
Salinity0 - 199.9 ppt, 0% - 20%1 ppm (<1999 ppm), 10 ppm (>1999 ppm), 0.1 ppt, 0.01%±2% F.S
CF0 - 1999.0 CF1 CF±2% F.S
Temperature0 - 50°C (32 - 122°F)0.1°C (0.2°F)±1.0°C (±2°F)

General Specifications:

  • Power Supply: DC6V (via included power adapter)
  • Temperature Compensation: 0°C - 50°C
  • Operating Temperature: 0°C - 50°C
  • Dimensions: 152 mm x 80 mm x 26 mm (5.98 in x 3.07 in x 0.98 in)
  • Weight: 245g
  • Probe Wire Length: 1.1m (43.31 in)
  • Display Type: DIGITAL with Backlight
  • Smart Device: Yes, Tuya Smart APP compatible
Dimensions of the PH-W218EU monitor and probe wire length
Figure 3: Device dimensions and probe wire length.

5. Setup

5.1. Physical Installation

The PH-W218EU features a wall-mounted design for easy installation. Use the provided suction cups and clip to secure the monitor and probes in your desired location.

Wall-mounted installation of the PH-W218EU with probes immersed in an aquarium
Figure 4: Wall-mounted design with probes in an aquarium. Note: This tester is not waterproof. Do not let it get wet or damp.

5.2. Connecting Probes

Connect the pH electrode, ORP electrode, temperature electrode, and PPM/EC/SALT/S.G./CF probe to their respective ports on the monitor. Ensure connections are secure.

Detailed view of PH-W218EU monitor showing probe connection points and control buttons
Figure 5: Probe connection points and control buttons on the PH-W218EU monitor.

5.3. Powering On

  1. Connect the power adapter to the device and then to a suitable power outlet (110V US Plug or 220V EU Plug, depending on your model).
  2. The device will power on automatically.

6. Operation

6.1. General Measurement

  1. Remove the protective caps from the electrodes.
  2. Clean the electrodes with distilled water and dry them well.
  3. Immerse the pH electrode, ORP electrode, temperature electrode, and TDS electrode into the testing solution. Stir lightly and wait a few seconds for a stable reading.
  4. The current measurements will be displayed on the LCD screen.

6.2. Switching Temperature Units (°C/°F)

Short press the "TEMP CAL" key to switch between Celsius (°C) and Fahrenheit (°F) temperature displays.

Illustration of pressing the TEMP CAL button to switch between Celsius and Fahrenheit
Figure 6: Switching temperature units.

6.3. Selecting Measurement Parameters (PPM/EC/SALT/S.G/CF)

Short press the "MODE" key to cycle through and select different measurement parameters for the combined probe: PPM, EC, SALT, S.G, or CF.

Illustration of pressing the MODE button to cycle through PPM, EC, SALT, S.G, CF measurements
Figure 7: Selecting measurement parameters using the MODE button.

6.4. Turning WiFi On/Off

Long press the "MODE" key to turn the WiFi function on or off.

7. Calibration

7.1. Calibration Notice

Calibration is essential for maintaining the accuracy of your water quality tester. Recalibration is required in the following cases:

  • If the device has not been calibrated for a long time.
  • For regular and long-term continual use.
  • When high accuracy is required for measurements.

7.2. pH Calibration (3 Points)

  1. Prepare three clean beakers and pour standard buffer solutions of pH 6.86, pH 4.00, and pH 9.18 (at 25°C) into them separately. For accurate calibration, fill two beakers with the same buffer solution (e.g., pH 6.86); one for cleaning the electrode and one for calibration to reduce pollution.
  2. Plug in and turn on the device.
  3. Immerse the pH electrode into the pH 6.86 standard buffer solution. Stir gently until the value is stable.
  4. Long press the "TEMP CAL" key for 5 seconds. The screen will display "06.86" and "28.2" (temperature), indicating it has entered pH 6.86 automatic correction mode. The meter will automatically identify standard buffer solutions of pH 4.00 and pH 6.86. Once the displayed value corresponds to the standard buffer solution, calibration is complete for this point.
  5. Clean the electrode with distilled water.
  6. Immerse the electrode into the pH 4.00 standard buffer solution. Long press the "TEMP CAL" key for 5 seconds when the display value is stable. The screen will display "04.00" and "28.2", entering pH 4.01 automatic calibration mode. Calibration is complete for this point when the displayed value matches the buffer solution.
  7. Clean the electrode with distilled water.
  8. Immerse the electrode into the pH 9.18 standard buffer solution. Long press the "TEMP CAL" key for 5 seconds when the display value is stable. The screen will display "09.18" and "28.2", entering pH 9.18 automatic calibration mode. Calibration is complete for this point when the displayed value matches the buffer solution.
  9. Users can choose calibration solutions from 6.86, 4.00, 9.18, or 7.00, 4.00, 10.00. The factory default calibration is 6.86, 4.00, 9.19.

7.3. EC Calibration

  1. Turn on the meter. Press the "MODE" key to select EC-ms.
  2. Immerse the electrode into distilled water for about five minutes to activate it.
  3. Immerse the electrode into 12.88 ms/cm EC calibration solution (at 25°C) and stir gently.
  4. When the reading is stable, long press the "CAL" key for about 5 seconds. The screen will display "12.80" or "12.70-12.90".
  5. Clean the electrode with distilled water and dry it with filter paper.
  6. Immerse the electrode into 1.413 ms/cm EC calibration solution (at 25°C) and stir gently. The display value should be the same as or close to the calibration solution value.
  7. Clean the electrode with distilled water and dry it with filter paper.

7.4. ORP Calibration

  1. Plug in the power to turn on the device.
  2. Immerse the ORP electrode into distilled water for five minutes.
  3. Immerse the ORP electrode into 265 mV ORP calibration solution (at 25°C) and stir gently.
  4. When the reading is stable, press and hold the "CAL" key for about 5 seconds. The screen will display "265" or a similar value.
  5. Clean the electrode in distilled water and dry with filter paper.
  6. Immerse the electrode in 100 mV ORP calibration solution (at 25°C) and stir gently until the display value is the same as or close to the calibration solution value.
  7. Clean the electrode with distilled water and dry with filter paper.

8. Mobile Application Monitoring (Tuya Smart APP)

The PH-W218EU is a 24-hour online monitoring tool compatible with Apple (iOS) and Android systems via the Tuya Smart APP.

Mobile application monitoring interface for PH-W218EU showing various parameters and compatibility with iOS and Android
Figure 8: Tuya Smart APP interface for PH-W218EU monitoring.

8.1. App Download and Installation

  1. Search for "Tuya Smart" in your mobile phone's app store (Google Play Store for Android or Apple App Store for iOS).
  2. Download and install the application.
  3. Register for an account or log in if you already have one.

8.2. Device Connection

  1. Open the Tuya Smart APP.
  2. Click "Add Device" (usually a '+' icon or similar). The app will search for nearby devices.
  3. Ensure your mobile phone and the PH-W218EU device are connected to the same WiFi network.
  4. Long press the "MODE" key on the meter to turn on WiFi (if not already on).
  5. Select the discovered device (e.g., "WiFi smart online 8 in 1 tester") in the app.
  6. Enter your WiFi password when prompted and click "Next".
  7. Once connected, the device will appear in your app's device list.
WiFi connection and data transfer process to Tuya Smart app, showing the device connected to an aquarium
Figure 9: WiFi connection and real-time monitoring via Tuya Smart APP.

8.3. Real-time Data Monitoring

Once connected, you can view various parameters in real-time on the Tuya Smart APP. The app allows you to view details over day, week, or month periods.

Real-time pH data detection on the Tuya Smart app with a pH scale from acidic to alkalinity
Figure 10: Real-time pH data detection and pH scale in the app.

8.4. Alarm Settings

You can set up alarms within the Tuya Smart APP to be notified when specific parameters exceed or fall below set thresholds. For example, you can set a pH low alarm. When the pH value drops below the set threshold, the app will send an alarm message.

8.5. Multi-device Control

The Tuya Smart APP allows one mobile phone to control multiple devices simultaneously, including multiple PH-W218EU units or other compatible smart devices.

Diagram showing one mobile phone controlling multiple PH-W218EU devices via WiFi
Figure 11: One mobile phone can control multiple devices.

9. Data Management

9.1. Data Logging and Storage

The device automatically stores and saves data for up to 30 days. Data is received at all times, with a set of data transmitted every 15 seconds. The app provides data curve graphs for analysis.

Data logging capacity showing 60 groups per hour, 7 groups per week, and 30 groups per month
Figure 12: Data logging capacity and frequency.

9.2. Exporting Data to Excel/Email

You can export your measurement data to an Excel file and send it to your email for viewing and sharing. The export is sent directly to your mailbox in the form of a report. After receiving the email, you need to click 'Download' to access the file.

Steps for exporting data to Excel via email from the mobile app: Click Export, Enter Email, Open and Share
Figure 13: Steps for exporting data to Excel via email.

10. Maintenance

10.1. Electrode Cleaning

Regularly clean the electrodes with distilled water, especially before and after calibration and measurement, to ensure accurate readings and prolong their lifespan.

10.2. General Care

  • Always keep the instrument dry and ensure the environment is well-ventilated and dry when using or storing.
  • Do not let the tester get water or damp during use, as it is not waterproof. Otherwise, the tester may not work normally.
  • Store the electrodes with their protective caps on when not in use to prevent them from drying out.

11. User Tips

  • Continuous Operation: The PH-W218EU is designed for 24-hour online monitoring, making it suitable for continuous operation in aquariums, hydroponics, and other systems.
  • Probe Cable Length: The sensor cables for the probes are approximately 1.1 meters (43.31 inches) long, providing flexibility for placement.
  • WiFi Monitoring: For smartphone monitoring, the device and your smartphone need to be connected to the same WiFi network. The smartphone does not need to be physically close to the equipment as long as both are within the WiFi network's range.
  • Calibration Frequency: The frequency of calibration depends on the application and required accuracy. For freshwater aquariums or applications requiring high accuracy and continuous use, regular calibration (e.g., monthly or as needed based on drift) is recommended.

12. Warranty and Support

All defects in materials and manufacture of this device are guaranteed for one year from the date of purchase. Within this one-year period, please contact your dealer or our office for free repair if the damage is not caused by the user's negligence or wrong operation.

For further assistance, please refer to the comprehensive user manual PDF available online: Download User Manual (PDF).

13. Safety Warnings

  • This tester is not waterproof. Please do not let the tester get water or damp during use. Otherwise, the tester may not work normally.
  • Always keep the instrument dry and ensure the environment is ventilated and dry when using.
  • Keep out of reach of children.
  • Use only the provided power adapter.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.