Danfoss BFP 21 R3 L3 R5 L5

Contents

BFP 21 Series Diesel Oil Pump Instruction Manual

Model: BFP 21 R3, BFP 21 L3, BFP 21 R5, BFP 21 L5

Brand: Danfoss

1. Introduction

The BFP 21 series oil pumps are designed for use in the oil combustion systems of oil burners or dual-purpose burners. These pumps are compatible with both kerosene and diesel fuels. Users can configure the pump for either single or double pipe oil supply as needed.

This model features integrated solenoid valves, making it suitable for commercial and thermal industrial applications requiring pressure regulation. It is a high-tech pump designed for robust industrial use, incorporating an integrated pressure regulator and a preheating device.

  • Pressure Range: 14 bar (nominal)
  • Max. Flow Rate: 45 L/h (for BFP 21R3 and BFP 21L3 models); 70 L/h (for BFP 21R5 and BFP 21L5 models)
  • Rotation Note: 'L' indicates anticlockwise rotation, while 'R' indicates clockwise rotation.
Two Danfoss BFP 21 series oil pumps, models R3 and L5, with solenoid valves.
Figure 1: Danfoss BFP 21 R3 and BFP 21 L5 Diesel Oil Pumps.
Two Danfoss BFP 21 L3 oil pumps, showing the top view with 'P' and 'V' ports and rotation arrows.
Figure 2: Top view of two BFP 21 L3 pumps, indicating ports and rotation.
Danfoss BFP 21 R5 oil pump, showing the top view with 'P' and 'V' ports and rotation arrows.
Figure 3: Top view of a BFP 21 R5 pump.
Danfoss BFP 21 L5 oil pump, showing the top view with 'P' and 'V' ports and rotation arrows.
Figure 4: Top view of a BFP 21 L5 pump.

2. Technical Specifications

The following table details the technical specifications for the BFP 21 series oil pumps:

Attribute Specification
Model BFP21L3, BFP21R3, BFP21L5, BFP21R5
Oil Types Standard fuel gas oil and fuel oil acc. to DIN V 51603-6 EL A Bio 10 (max. 10% FAME)
Fuel Oil Viscosity Range (1.3) 1.8 - 12.0 cSt. (mm²/s)
Filter Type Tube type oil filter, Cartridge filter
Filter Area 11 cm²
Filter Mesh 200 µm
Pressure Range 7 - 20 Bar
Factory Set Pressure 10 ± 1 Bar
Max. Inlet/Return Pressure 2 Bar
Power 9 W (Coil power consumption)
Rated Voltage 230 V, 50/60 Hz (other voltages on request)
Speed 2400 - 3450 min⁻¹
Max. Starting Torque 0.1 Nm (BFP 20/21), 0.12 Nm (BFP 20/21)
Ambient/Transport Temperature -20 to +70 °C
Medium Temperature 0 to +70 °C
Coil Enclosure IP 40
Shaft/Neck EN 225
Material Metal
Capacity ≤20L (General)
Sprayer Type TRIGGER
Origin Mainland China
Technical data table for BFP 20/21 oil pumps, including specifications for oil types, viscosity, filter, pressure, speed, temperature, and coil details.
Figure 5: Detailed Technical Data for BFP 20/21 Series.
Data sheet for BFP 20/21 oil pump, size 3 and 5, detailing application, features, function, bleeding, cut-off function, and warranty information.
Figure 6: Data Sheet for BFP 20/21 Oil Pump, Sizes 3 and 5.

3. Setup and Installation

The BFP 20/21 series oil pumps are designed for small/medium-sized domestic oil burners. Proper installation is crucial for optimal performance and safety.

3.1 Connections

Refer to Figure 7 for an example of connections on a BFP 21 5L pump. Key connection points are:

  • P₁: Pressure adjustment
  • S: Suction inlet G1/4
  • R: Return outlet G1/4
  • E: Nozzle outlet G 1/8
  • P: Pressure gauge port G 1/8
  • V: Vacuum gauge port G 1/8
  • H: Filter

Shaft rotation (R-rotation for Right-hand, L-rotation for Left-hand) and the location of the nozzle outlet and other connections are determined from the shaft end view.

3.2 Pipe Configuration (Change-over)

The pump can be configured for either 1-pipe or 2-pipe operation:

  • 2-pipe operation: Install with the screw (A) in place.
  • 1-pipe operation: Remove the screw (A). In 1-pipe systems with a plugged return outlet (R) and screw (A) removed, the oil is returned internally to the gear set.

3.3 Mounting Considerations

Important Note: Do not mount the pump with the solenoid valve pointing downwards.

Diagram showing connections for a BFP 21 5L pump, including pressure adjustment, suction, return, nozzle, pressure gauge, vacuum gauge ports, and filter. Also shows change-over for 1-pipe and 2-pipe operation and pump dimensions.
Figure 7: Connections, Change-over, and Dimensions for BFP 21 Series.
Multi-language table identifying components and connections for the LE-S System, including P for Pressure, S for Suction line G1/4, R for Return line G1/4, E for Nozzle conn. G1/8, V for Vacuum meter conn. G1/8, P for Pressure gauge conn. G1/8, and Filter for Cartridge filter.
Figure 8: Component Identification for LE-S System (English column).

4. Operating Principles

The BFP 21 oil pump operates by drawing oil from the suction inlet (S) through the filter (H) to the gear set. Within the gear set, the oil pressure is increased. When an electrical voltage is applied to the NC-valve, it opens, allowing oil to be released to the nozzle outlet.

4.1 Pressure Regulation

An internal diaphragm (D) in the pressure regulator (T) maintains a constant pressure, which is set via the adjustment screw (P1).

4.2 Bleeding

  • In 2-pipe systems: The pump is self-priming. Bleeding occurs automatically via the constriction (O) to the return outlet (R).
  • In 1-pipe systems: Bleeding must be performed through the nozzle outlet (E) or the pressure gauge port (P).

4.3 Cut-off Function (Solenoid Valve)

For BFP 21 models, when the burner stops, the voltage to the NC-valve is cut off, immediately stopping the oil flow to the nozzle outlet. BFP 20 models do not have an integrated solenoid valve; a separate cut-off valve must be installed in the nozzle line for these systems.

Diagram illustrating the function of the BFP 20/21 oil pump, showing pressure, suction, and return lines, and explaining the oil flow path, pressure regulation, bleeding, and cut-off function.
Figure 9: Functional Diagram of BFP 20/21 Oil Pump.
Graphs showing nozzle capacity versus pressure and operating torque versus power consumption for BFP 20/21 oil pumps.
Figure 10: Nozzle Capacity and Operating Torque Graphs.

Video 1: Product Overview and Operation.

5. Maintenance

Regular maintenance of your oil pump and burner system is essential for efficient operation and longevity. A well-adjusted oil burner can significantly improve efficiency and reduce oil consumption.

5.1 Filter Replacement

The pump includes a cartridge filter (H) that should be regularly inspected and replaced as part of routine maintenance. Refer to Figure 7 for the filter location.

5.2 Solenoid Valve Replacement

The solenoid valve has an approved life expectancy of 250,000 operations or 10 years. It must be replaced after reaching either of these limits.

5.3 Benefits of Annual Service

Annual service helps ensure:

  • Energy savings
  • Cost savings
  • Minimum pollution
  • Longer burner lifetime
  • Avoid breakdowns
  • Greener heating
  • Consistent warmth

If soot builds up in the burner, oil usage can increase by 2-4% per millimeter of soot layer. Regular cleaning and servicing prevent this inefficiency.

Images showing maintenance procedures: checking the filter, inspecting the nozzle, and adjusting pump settings with a wrench.
Figure 11: Visual examples of oil burner maintenance, including filter and nozzle inspection.

6. Troubleshooting

This section provides guidance on common issues you might encounter with your oil pump.

6.1 General Issues

  • No oil flow: Check for blockages in the suction line or filter (H). Ensure the solenoid valve is receiving power and opening correctly.
  • Incorrect pressure: Verify the pressure setting using the adjustment screw (P1) and a pressure gauge connected to port P.
  • Pump not self-priming (1-pipe system): Ensure the return outlet (R) is plugged and screw (A) is removed for internal return. Bleed the system through the nozzle outlet (E) or pressure gauge port (P).

6.2 Solenoid Valve Malfunction

If the solenoid valve is not functioning, check its electrical connection. If the valve is old or has exceeded its operational cycles (250,000 operations or 10 years), it may need replacement.

6.3 Oil Quality Issues

Using oil containing abrasive particles can void the warranty and lead to pump damage. Ensure you use standard fuel gas oil or fuel oil according to DIN V 51603-6 EL A Bio 10 (max. 10% FAME).

7. User Tips

No specific user tips were available from reviews or Q&A for this product at this time. Always refer to the official documentation and consult a qualified technician for complex installations or repairs.

8. Warranty and Support

8.1 Manufacturer Warranty

This product comes with a 1-year manufacturer warranty.

  • First 3 Months: Free new parts or accessories will be provided with free shipping.
  • 3 Months to 1 Year: Free new parts or accessories will be provided, but you may need to cover some shipping fees.

The warranty may be voided for pumps used outside the stated technical data or with oil containing abrasive particles.

8.2 Reporting Issues

  • Defective Product: Problems must be submitted within 7 business days after product delivery.
  • Shipping Damage: Issues must be submitted within 5 business days after product delivery.

Please provide photos or videos when reporting problems with the product to facilitate the resolution process.

8.3 Contact Information

For bulk wholesale orders or inquiries about multiple products, please contact the seller directly for potential discounts.

Contact information for Yaoshun Spray Technology Co., Ltd., including WhatsApp, Wechat, Skype, QQ, and Gmail addresses.
Figure 12: Seller Contact Information.

© 2024 Danfoss. All rights reserved. This manual is for informational purposes only.