1. Introduction
Congratulations on receiving your AFU AF300 Battery Charger! This manual provides essential information for the safe and efficient operation of your charger. Please read it carefully before use.
If you have any questions, concerns, or missing parts, please contact the retailer.
2. Package Contents
Please check the package for the following items:
- 1 x AFU AF300 Battery Charger
- 1 x AC Input Power Cord
- 1 x User Manual (this document)
- 2 x Fuses (spare)
This battery charger is designed for optimal performance without sacrificing affordability. It features an integrated MCU and PWM for precise power control.
3. Product Overview
The AFU AF300 charger is housed in a robust aluminum case, designed for durability and efficient heat dissipation. It features an OLED display for real-time monitoring of charging parameters.

Figure 1: Front view of the AFU AF300 Battery Charger with OLED display.

Figure 2: Back view of the charger, highlighting the input interface, fuse, cooling fan, and output wire.

Figure 3: Charger dimensions (135x90x50mm) and weight (1KG).

Figure 4: Product Structure Diagram.
Video 1: Product overview and basic setup demonstration.
4. Specifications
| Feature | Specification |
|---|---|
| Brand Name | AFU |
| Model Number | AF300-84035B |
| AC Input Voltage | 100~120V/200~240Vac |
| Frequency | 50~60Hz |
| DC Output Voltage | 84 Volt |
| DC Output Current | 3.5 Amp |
| Dimension | 135mm x 90mm x 50mm (5.3 x 3.54 x 1.97 inches) |
| Net Weight | 1KG (2.2 lbs) |
| Case Color | Black |
| Case Material | Aluminum |
| Suitable Battery Type | 20S 74V Li-ion Lipo Battery (Series Connection) |
| Efficiency | ≥85% |
| Charging Mode | Three-stage Intelligent Charging: Constant Current, Constant Voltage, Trickle (Floating Charge) |
| Charging Indicator | Red (charging), Green (finished/standby) |
| Operating Temperature | -20°C to +40°C (-4°F to 104°F) |
| Storage Temperature | -40°C to +70°C (-40°F to 158°F) |
| Relative Humidity | 5% to 95% (Operating), 0% to 95% (Storage) |
| Max. Altitude | 10000 meters (Operating), 20000 meters (Storage) |
| Voltage Range | High voltage (50-1000V DC, 75-1000V AC) |
| Max. Output Power | 294W |
| Output Power | 150-500W (including 500W) |
| Power Source | AC & DC |
| Display Screen | Yes |
| Intelligent Charge | Yes |
| Quick Charge | No |
| Certifications | CE, FCC, RoHS |
5. Setup Instructions
- Connect the Charger: Connect the detachable AC input power cord to the charging unit. Ensure a tight connection.
- Connect to Battery: Plug the DC output plug into the battery charging socket on your battery.
- Observe Indicators: Upon successful connection to the battery, LED1 will turn red (power on) and LED2 will turn red (charging).
- Connect to Power Outlet: Connect the AC input power cord to a suitable electrical outlet. Do not face the battery when making this connection.
- Monitor Charging: Keep your battery charging until the LED2 light turns green, indicating that it is fully charged.
- Automatic Maintenance: If the charger remains plugged in after full charge, automatic maintenance mode will activate, continuously monitoring the battery for optimal storage.
- Disconnect: First, disconnect the DC output plug from your battery, then disconnect the AC power cord from the electrical outlet.
- Storage: Store your battery charger in a dry environment.

Figure 5: LED Indicators for charging status.
6. Operating Instructions
The AFU AF300 charger operates with a three-stage intelligent charging mode to protect and preserve your batteries:
- Stage 1: Constant Current (CC) - The charger delivers a constant current to the battery until it reaches a certain voltage level.
- Stage 2: Constant Voltage (CV) - The charger maintains a constant voltage while the current gradually decreases.
- Stage 3: Float Charging / Trickle Charging - Once the battery is nearly full, the charger switches to a lower current to maintain the battery's charge without overcharging. This stage is particularly relevant for Lead-acid chargers.

Figure 6: Charging Curve for Lead-acid and Lithium-ion/LiFePO4 batteries.
The OLED display provides real-time information on voltage, electric current, temperature, and power output during operation.
7. Troubleshooting
- Charger shows no indication when plugged in:
- Check if the input AC voltage (110V or 220V) matches the charger's requirement.
- Verify if the input AC line fuse is damaged.
- LED1 is red and LED2 is green, but nothing happens when output plug is inserted into battery:
- Ensure the output plug is fully inserted into the battery.
- Check for any loose or corroded connections on your battery terminals or the charger's output fuse.
- Battery meter reads full, but charger is still running: Many aftermarket battery meters require 12-24 hours after charging to accurately read the battery state. Allow the charger to complete its full charge cycle.
- Batteries sound like they are “boiling” (applies to lead-acid batteries): This sound is typically the release of hydrogen gas bubbles during the bulk recharge phase, which helps stir up sediment. If fluid is bubbling out, immediately disconnect the charger as this may indicate too much fluid has been added.
- LEDs stay illuminated for a period after unplugging from AC power: This is normal and does not affect your batteries. It is a function of precision charging, ensuring the charger is disconnected prior to terminating the charge cycle.
8. Maintenance
To ensure the longevity and optimal performance of your AFU AF300 Battery Charger:
- Always use the charger in a well-ventilated and dry environment.
- Do not cover the aluminum case during operation, as this can cause the charger to overheat.
- Regularly inspect the power cords and plugs for any signs of damage or corrosion.
- Keep the charger clean and free from dust.
9. Important Safety Instructions
WARNING: Failure to follow these safety instructions may result in electric shock, fire, or serious injury.
- Do not attempt to repair or service the charger yourself. Opening the charger may expose you to high voltages, the risk of electric shock, and other hazards.
- Ensure the local power grid voltage is consistent with the AC configuration of the charger to avoid incorrect input voltage.
- Avoid charging the wrong type of battery.
- Always check connector/cable polarity before connecting to the battery.
- Do not cut or splice the AC power cord. Damaged cords and plugs can cause electric shock or electrocution.
- When using an extension cord, make the AC connection to the charger outside of the battery compartment as far away as practical to reduce the risk of a spark igniting gases.
- Even though the charger is capable of operating in a high ambient temperature environment, a minimum of six inches of unobstructed area should be allowed on all sides of the unit for proper air circulation and cooling.
- Do not submerge the charger in water or allow it to get wet.
- Sparking is normal due to high current when connecting the charger to the battery.
- Do not disassemble the charger.
- Risk of electrical shock. Do not touch uninsulated portions of AC or DC connectors or uninsulated battery terminals.
- To prevent electrical shock, make sure all electrical connectors are in good working condition. Do not use connectors that are cracked, corroded, or do not make adequate electrical contact.
- Never alter the AC cord or plug provided. If it will not fit the outlet, consult a qualified electrician. Improper connection can result in electric shock.
10. User Tips
- For optimal battery health, ensure the charger is placed in a well-ventilated area during use to prevent overheating.
- Always double-check the battery type and voltage compatibility before connecting to avoid damage.
- If you notice any unusual sounds or smells during charging, disconnect the charger immediately and consult the troubleshooting section or contact support.
11. Warranty and Support
The AFU AF300 Battery Charger comes with a 12-month manufacturer's warranty from the date of purchase.
Warranty is not provided in the following cases:
- Damage caused by installation and use in violation of product instructions.
- Damage caused by unauthorized modification or repair.
- Exceeding the specified use environment, natural disasters, or other force majeure events.
For any questions, concerns, or support regarding your product, please contact the online retailer where you purchased the charger. You may also refer to the official user manual PDF for additional details: View User Manual (PDF).

Figure 7: Contact Information for AFU Official Store.
12. Frequently Asked Questions (FAQ)
- Q: How loud should the charger be?
- A: The noticeable sound of rushing air from the fan is a normal part of the cooling process for your rapid charger.
- Q: How warm do chargers get?
- A: The battery chargers can reach up to 140°F (60°C). They may get warm in an enclosed area. The maximum recommended air temperature for charging batteries is 105°F (40.5°C). When the charger is hot, the output current will drop to protect the charger and the battery.
- Q: Will I damage my batteries if I leave the charger plugged in over long periods of non-use (like storage)?
- A: No. You only need to place the charger in a well-ventilated and dry environment, and the charger will not be damaged. The automatic maintenance mode will keep your battery optimally charged.
- Q: Why do the LEDs on my charger stay illuminated for a period of time after unplugged from AC power?
- A: This is normal and does not affect your batteries. It is simply a function of the precision charging, ensuring the charger is disconnected prior to terminating the charge cycle.
- Q: What is the warranty?
- A: The manufacturer's warranty is 12 months.