Jebao SCP-50, ECP-50, ECP-50M WIFI

Contents

Jebao SCP-50 / ECP-50 / ECP-50M WIFI Wave Pump Instruction Manual

Brand: Jebao | Models: SCP-50, ECP-50, ECP-50M WIFI

1. Introduction

This manual provides instructions for the installation, operation, and maintenance of your Jebao SCP-50, ECP-50, or ECP-50M WIFI wave pump. These pumps are designed to create natural wave patterns and circulation in marine and freshwater aquariums, promoting a healthy environment for your aquatic life. Featuring SINE wave technology for ultra-quiet and stable performance, a cross-wave double impeller structure for optimal water flow, and no exposed copper elements, these pumps are suitable for various aquarium setups.

2. Important Safety Instructions

  • Read all instructions before using this appliance.
  • Always ensure the pump is fully submerged in water before operation. Running the pump dry will cause damage.
  • The maximum water temperature for operation is 35°C (95°F). Do not exceed this temperature.
  • The pump is designed for indoor aquarium use only.
  • Input power: AC 100-240V, 50/60Hz. Output: DC 24V, 12W. Ensure your power supply matches these specifications.
  • The pump is rated IPX8, meaning it is protected against continuous immersion in water. However, the controller and power adapter are not waterproof and must be kept dry.
  • Always disconnect power to the pump and all other aquarium equipment before performing any maintenance or handling the pump.
  • Do not operate any appliance with a damaged cord or plug, or if the appliance malfunctions or has been dropped or damaged in any manner.
  • Do not attempt to repair this appliance yourself. Refer all servicing to a qualified service facility or return to the place of purchase.
  • To avoid the possibility of the appliance plug or receptacle getting wet, position the aquarium stand and tank to one side of a wall-mounted receptacle to prevent water from dripping onto the receptacle or plug. A "drip loop" should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. The "drip loop" is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water from traveling along the cord and coming into contact with the receptacle. If the plug or receptacle does get wet, DO NOT unplug the cord. Disconnect the fuse or circuit breaker that supplies power to the appliance. Then unplug and examine for presence of water in the receptacle.

3. Package Contents

Your package should contain the following items:

  • Jebao Wave Pump Unit (SCP-50, ECP-50, or ECP-50M WIFI model)
  • External Controller (for SCP-50 and ECP-50 models)
  • Power Adapter (appropriate for your region: EU, US, UK, or AU plug type)
  • Magnetic Mount
Jebao SCP-50 Sine Cross-Flow Pump unit and controller
SCP-50 Pump Unit and Controller
Jebao ECP-50M Smart Cross-Flow Pump packaging box
ECP-50M Packaging (Smart Cross-Flow Pump)
Jebao power adapter with US plug
Power Adapter (US plug shown, other types available)

4. Installation and Setup

  1. Choose Placement: Select a suitable location inside your aquarium for the pump. Ensure it is fully submerged and positioned to create the desired water flow without disturbing substrate or corals.
  2. Mounting: The pump uses a magnetic mount. Place the pump unit inside the aquarium and align the external magnet on the outside of the glass. The pump is suitable for glass thickness up to 8mm.
  3. Connect Controller (SCP-50/ECP-50): Connect the pump's cable to the designated port on the external controller.
  4. Connect Power Adapter: Plug the power adapter into the controller (if applicable) or directly into the pump unit (for ECP-50M WIFI models).
  5. Power On: Plug the power adapter into a suitable electrical outlet. Ensure a drip loop is formed with the power cord to prevent water from reaching the outlet.
  6. Initial Check: Once powered on, the pump should start operating. Observe the water flow and adjust placement if necessary.
Jebao SCP-50 pump unit with power cable
SCP-50 Pump Unit
Jebao ECP-50 pump unit with power cable
ECP-50 Pump Unit
Jebao ECP-50M WIFI pump unit with power cable
ECP-50M WIFI Pump Unit

5. Operating Instructions

5.1. SCP-50 / ECP-50 Controller Functions

The external controller for SCP-50 and ECP-50 models features several buttons to adjust pump operation:

Jebao SCP-50 controller with buttons: MODE/WAVE, SPEED/FEED, W.L./LOCK
SCP-50 Controller Interface
  • MODE/WAVE Button: Press to cycle through different wave patterns and operating modes.
  • SPEED/FEED Button:
    • Speed Adjustment: In normal operating modes, press to adjust the flow speed/intensity of the pump.
    • Feed Mode: Long press to activate feed mode, which temporarily pauses the pump to allow for feeding without food being immediately swept away.
  • W.L./LOCK Button:
    • Wireless Control (W.L.): This pump supports master and slave wireless control for synchronized operation of multiple units. Refer to the full user manual for detailed pairing instructions.
    • Lock Function: Long press to lock the current settings, preventing accidental changes.

5.2. ECP-50M WIFI Model Operation

The ECP-50M WIFI model offers smart control via a mobile application. Download the official Jebao app from your smartphone's app store (e.g., Apple App Store, Google Play Store). Follow the in-app instructions to connect your pump to your home Wi-Fi network and control its various modes and settings remotely.

ECP-50M box showing App Store and Google Play logos
ECP-50M packaging indicating app control

6. Maintenance

Regular maintenance is crucial for the longevity and optimal performance of your wave pump.

  1. Disconnect Power: Always unplug the pump from the power outlet before performing any maintenance.
  2. Remove from Aquarium: Carefully remove the pump unit from the aquarium.
  3. Disassembly: Gently twist or unclip the pump housing to access the impeller chamber. Refer to the full user manual for specific disassembly instructions for your model.
  4. Clean Impeller and Housing: Use a soft brush and clean water (or a mild vinegar solution for stubborn calcium deposits) to clean the impeller, impeller shaft, and the inside of the pump housing. Ensure all debris, algae, and mineral buildup are removed.
  5. Inspect Components: Check the impeller for any signs of wear or damage. Ensure the power cord is intact and free from nicks or cuts.
  6. Reassembly: Carefully reassemble the pump, ensuring all parts are securely fitted.
  7. Reinstall: Place the pump back into the aquarium, ensuring it is fully submerged before reconnecting power.

7. Troubleshooting

ProblemPossible CauseSolution
Pump not runningNo power; Controller/app settings; Impeller jammedCheck power connection; Verify controller/app settings; Clean impeller and housing
Weak or inconsistent flowBlocked intake/output; Dirty impeller; Air in pumpClean pump intake/output; Clean impeller; Gently shake pump to release trapped air
Excessive noiseImpeller obstruction/wear; Improper seating; Dry runningClean impeller; Ensure pump is fully submerged and securely mounted; Check for damage to impeller or shaft
WIFI connection issues (ECP-50M)Incorrect network settings; Router distance; App issuesEnsure correct Wi-Fi password; Move pump closer to router; Restart app/phone; Consult app's help section

8. Specifications

FeatureSpecification
ModelsSCP-50, ECP-50, ECP-50M WIFI
VoltageDC 24V
InputAC 100-240V, 50/60Hz
Power (Watts)12W
Flow Rate1500-5000 L/H
Dimensions (SCP-50)122.5 x 45.5 mm
Recommended Tank Size (SCP-50)Up to 60 cm
Applicable Glass ThicknessLess than 8 mm
MaterialRubber
Fixed FormSitting (Magnetic Mount)
Waterproof RatingIPX8 (pump unit only)
Max Water Temperature35°C (95°F)
Table of specifications for SCP-50 including voltage, watts, dimensions, tank size, and tank thickness
SCP-50 Specifications Table

9. User Tips

  • Adapter Selection: Ensure you select the correct power adapter plug type (EU, US, UK, AU) for your region when purchasing or setting up the pump.
  • Cable Management: Use drip loops for all power cords to prevent water from reaching electrical outlets.
  • Regular Cleaning: To maintain optimal flow and prevent noise, clean the pump and impeller regularly, especially in tanks with high bioload or algae growth.
  • WIFI Setup (ECP-50M): For the ECP-50M WIFI model, ensure your smartphone and the pump are within reasonable range of your Wi-Fi router during initial setup.

10. Warranty and Support

For warranty information, technical support, or further assistance, please contact the manufacturer or your retailer. Keep your proof of purchase for warranty claims.

A detailed user manual in PDF format may be available for download. Please refer to the official product page or manufacturer's website for the most comprehensive guide: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.