1. Product Overview
This HKFZ Pure Sine Wave Inverter is a professional, multi-functional device equipped with an intelligent LCD display and robust protection systems. Utilizing MCU micro-processing control SPWM technology, it provides a stable pure sine-wave output suitable for inductive, capacitive, resistive, and mixed loads. It offers strong overload resistance, impact resistance, and a long service life, making it ideal for both household and professional power conversion needs.

2. Specifications
The inverter is available in two main power variants. Please ensure the inverter's voltage matches your battery system's voltage (e.g., a 12V battery requires a 12V inverter).

| Feature | Description |
|---|---|
| Output Waveform | Pure Sine Wave |
| Output Frequency | 50Hz |
| Input Voltage (DC) | 12V, 24V, 48V, 60V, 72V, 96V (must match battery voltage) |
| Output Voltage (AC) | 220-230V |
| Operating Voltage (12V) | 10.5V-15.5V |
| Operating Voltage (24V) | 22V-30V |
| Operating Voltage (48V) | 43V-58V |
| Operating Voltage (60V) | 50V-70V |
| Operating Voltage (72V) | 62V-90V |
| Output Efficiency | 90%-95% |
| Storage Temperature | -20°C ~ +60°C |
| Compatible Battery Types | Iron lithium battery, lead-acid battery, lithium battery, gel battery, etc. |
| Certification | CE |
| Type | DC/AC Inverters |
3. Appearance & Components
Familiarize yourself with the key components of your inverter:
- LCD Display: Shows input voltage, output power, working status, and fault codes.
- Inverter Switch: Controls the inverter's on/off.
- Output Sockets: Provide 220V~230V AC household power output.
- AC Output Terminal: For connecting electrical appliances.
- Battery Positive Terminal: Connects to the positive pole of the battery.
- Battery Negative Terminal: Connects to the negative pole of the battery.
- Radiator Fan: Intelligent heat dissipation component.




4. Setup and Operation
4.1 Wiring & Operation Steps
- Confirm Voltage Match: Ensure the battery voltage precisely matches the inverter's specified input voltage (e.g., 12V battery for 12V inverter, 24V battery for 24V inverter, etc.).
- Connect Battery: Connect the battery positive wire to the inverter's "Battery Positive" terminal and the negative wire to the "Battery Negative" terminal. Do NOT reverse the connection.
- Secure Wiring: Verify all wiring is firm. If extending battery wires, use a heavier gauge wire (e.g., replace 10-square wire with 20-square wire) to prevent current transmission loss for high-power applications.
- Power On: Turn on the inverter switch. The LCD display should illuminate, indicating normal operation.
- Power Off: When not in use, immediately turn off the inverter switch to prevent damage to internal components and battery drain.


4.2 Radiator Fan Start-Up Modes
- Temperature-triggered: The fan starts automatically when the internal temperature reaches 45°C.
- Power-dependent: The fan runs continuously when high-power devices are connected and stops at low power.
- Intelligent Upgraded Mode: The fan's rotation speed adjusts adaptively based on the inverter's internal temperature.
5. Safety Guidelines and Restrictions
5.1 Key Usage Restrictions
- Voltage Mismatch Prohibition: Using a battery with a mismatched voltage (e.g., a 24V battery with a 12V inverter) will cause permanent damage to the inverter.
- Wire Gauge Requirement: Do not use undersized wires when lengthening connections. Insufficient wire gauge can lead to high current and malfunctions.
- Power Limitation: The usable power depends on battery capacity. Larger battery capacities support higher output power; small-capacity batteries cannot drive high-power devices.
- Overvoltage Protection: The 12V inverter's overvoltage protection activates at 15V. The inverter will stop working when overvoltage occurs.
5.2 Warnings
- No Reverse Connection Protection: This inverter does NOT have reverse connection protection. Reversing battery positive and negative wires will cause irreversible damage.
- High Voltage Hazard: Do not open the machine under any circumstances to avoid electric shock.
- Ventilation: Ensure the inverter is placed in a well-ventilated area for effective heat dissipation. Poor ventilation may trigger overheating protection or equipment damage.
- Correct Wiring: Use the correct type and gauge of wires to prevent fuse blowout due to excessive current.
- Cleaning: Before carrying or cleaning the inverter, turn off the switch and clean the surface with a dry cloth (avoid water contact).
- Environment: Keep the inverter away from flammable, explosive, and humid environments.
- Children: Keep out of reach of children without adult supervision.
- Moisture: Avoid the inverter from coming into contact with water or humid environments.
- Rated Power: Do not exceed the rated power of the inverter when using electrical appliances.
- Abnormalities: Immediately cut off all power if you smell burning, see smoke, hear abnormal noise, or notice overheating of the casing.
- Frequent Shutdowns: If the inverter frequently shuts down due to protection, check the load, battery, or heat dissipation system. Do not forcefully turn it on continuously.

6. Troubleshooting
Refer to the table below for common fault codes and their corresponding troubleshooting steps:
| Fault Code | Description | Troubleshooting |
|---|---|---|
| E01 | Short circuit fault | Check the output circuit for short circuits; restart after eliminating the fault. |
| E02 | Input undervoltage fault | Recharge or replace the battery (ensure voltage meets requirements). |
| E03 | High temperature protection | Improve ventilation; restart after the inverter cools down. |
| E04 | Overload protection | Reduce the load power to within the inverter's rated range. |
| E05 | Overvoltage protection | Check the battery voltage; ensure it matches the inverter's rated voltage. |
| E06 | Front-stage power overload | Reduce connected loads and restart the inverter. |
7. Product Characteristics
- Core Technology: MCU micro-processing control SPWM technology, pure sine-wave output with stable waveform.
- Load Adaptability: Compatible with inductive, capacitive, resistive, and mixed loads.
- Protection System: Equipped with input overvoltage/undervoltage, overload, overheating, and output short circuit protection.
- User-Friendly Design: LCD display for clear real-time status monitoring; intelligent radiator fan for efficient heat dissipation.



8. Applications
The Pure Sine Wave Inverter is versatile and can power a wide range of electrical appliances due to its pure sine wave output.



9. Certifications
The HKFZ Pure Sine Wave Inverter complies with various international regulations and harmonized standards:
- Low Voltage Directive (LVD) 2014/35/EU
Test Standards: EN 62109-1:2010; EN 62109-2:2011 - EMC Directive 2014/30/EU
Test Standards: EN IEC 61000-6-1:2019, EN IEC 61000-6-3:2021, EN IEC 61000-3-2:2019+A1:2021, EN 61000-3-3:2013+A2:2021+AC:2022 - MD Directive 2006/42/EC
Test Standards: EN 60204-1-2018; EN ISO 12100:2010 - RoHS 2.0 Directive 2011/65/EU Annex II (EU) 2015/863 as last amended by Directive (EU) 2017/2102.
Test Standards: EN IEC 63000:2018, EN 62321-1:2013, EN IEC 62321-2:2021, EN 62321-3-1:2014, EN 62321-4-2013+AMD1:2017, EN 62321-5:2014, EN 62321-6:2015, EN 62321-7-1:2015, EN 62321-7-2:2017, EN 62321-8:2017

10. Maintenance
To ensure the longevity and optimal performance of your inverter, follow these maintenance guidelines:
- Cleaning: Regularly clean the exterior of the inverter with a dry, soft cloth. Ensure the inverter is turned off and disconnected from all power sources before cleaning. Avoid using liquids or abrasive cleaners.
- Ventilation: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Periodically check that the radiator fans are operating correctly.
- Connections: Periodically inspect all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to power loss or overheating.
- Environment: Store and operate the inverter in a cool, dry, and well-ventilated area, away from direct sunlight, moisture, and flammable materials.
11. User Tips
- Voltage Compatibility: Always double-check that the inverter's input voltage (e.g., 12V, 24V, 48V) precisely matches your battery bank's voltage to prevent damage.
- Load Management: Ensure the total continuous power consumption of your connected appliances does not exceed the inverter's rated continuous power. Consider the peak power requirements for motor-type loads during startup.
- Wire Sizing: When extending battery cables, use appropriately thick wires to minimize voltage drop and ensure efficient power delivery. Consult a professional if unsure about wire gauge selection.
12. Warranty & Support
Quality Assurance:
- During the warranty period, we offer free repair or replacement of defective parts. Damaged parts must be returned to our company.
- The warranty period will automatically expire if the machine is disassembled, modified, or damaged due to improper use.
Please retain this manual and your purchase receipt (invoice) for warranty purposes. If you experience any malfunction with the inverter, please contact customer service promptly.
Additional Resources:
A detailed user manual in PDF format is available for download. This document provides further in-depth information and diagrams for your inverter. You can typically find this on the product's support page or by contacting customer service.