PowMr POW-HVM10.2M

Contents

PowMr 10.2KW Hybrid Solar Inverter User Manual

Model: POW-HVM10.2M

Brand: PowMr

1. Overview

The PowMr POW-HVM10.2M is a high-quality, all-in-one grid-tied hybrid solar inverter designed to meet the requirements of various environments. It features a built-in MPPT (Maximum Power Point Tracking) charging control module, offering a wide PV input voltage range of 90-500VDC. This inverter provides a dual-channel AC output configuration with a total capacity of up to 10.2KW, ensuring reliable power for your solar energy system.

It includes multiple built-in protection features to ensure the safety and longevity of your solar power system. The inverter is capable of connecting to 48V lithium batteries and supports various battery types, including Lifepo4, Lithium, Flooded, Gel, and Lead-acid batteries.

PowMr 10.2KW Hybrid Solar Inverter front view

Figure 1: Front view of the PowMr 10.2KW Hybrid Solar Inverter.

2. Features

  • Pure sine wave solar inverter (on/off Grid capability).
  • Can operate without a battery.
  • Output power factor of 1.0.
  • High PV input voltage range (90~500VDC).
  • WIFI & GPRS connectivity available for IOS and Android apps (WIFI module and GPRS data sold separately).
  • Built-in anti-dust kit for harsh environments.
  • Integrated 160A MPPT solar charge controller.
  • Smart battery charge design to optimize battery life.
  • One-click restoration to factory settings.
  • Dual AC output (Main output: 8200W, Auxiliary output: 2733W).
  • Built-in Lithium battery automatic activation function.
  • Intuitive touch button interface.
  • Equipped with 3 cooling fans and a demountable insect screen for easy cleaning.
  • Compatible with multiple battery types: AGM, GEL, FLD, LI, SLD, USER.
  • Provides 360° protection including: Short Circuit, Over Current, Over Voltage, Under Voltage, Over-Load, Backfill, Over-Temperature, Solar panel reverse connection, Battery overvoltage, and Over Charge protection.
Intelligent Protection Systems diagram

Figure 2: Diagram illustrating the 15 intelligent protection modes of the inverter.

3. Specifications

3.1 General Product Properties

  • Brand Name: PowMr
  • Model Number: POW-HVM10.2M-WIFI
  • Output Power: 1 - 200 KW (Rated Output Power: 10200W)
  • Output Type: SINGLE
  • Size: 537*390*130mm
  • Weight: 14.5KG
  • Output Frequency: 50HZ/60HZ
  • Output Current: MPPT 160A
  • Is Smart Device: Yes
  • Origin: Mainland China
  • Certification: CE
  • Item: grid-tied solar inverter
  • Product: on/off grid inverter
  • Charging: pure sine wave inverter
  • PV array MPPT voltage range: 90Vdc-500Vdc
  • Output voltage range: 220/230/240Vac
  • Battery type: Lifepo4, Lithium, Flooded, Gel, Lead-acid Battery
  • Feature 1: Built-in Lithium battery automatic activation
  • Feature 2: Double AC output
  • Load type: Household appliances, farm tools
  • Applicable equipment: Factory equipment, commercial load, industrial machinery
  • Applicable area: Asia, Europe, Africa and North America (220-240VAC drivers)

3.2 Detailed Specifications Tables

Table 1: Line Mode Specifications
INVERTER MODELPOW-HVM8.2MPOW-HVM10.2M
Input Voltage WaveformPure Sine Wave (Utility or Generator)
Nominal Input Voltage230Vac
Max AC Input Voltage300Vac
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)
Table 2: Inverter Mode Specifications
INVERTER MODELPOW-HVM8.2MPOW-HVM10.2M
Rated Output Power8.2KW10.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50HZ
Peak Efficiency0.93
Overload Protection3s@≥150% load; 5s@101%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage48Vdc48Vdc
Cold Start Voltage46.0Vdc46.0Vdc
No Load Power Consumption70W75W
Table 3: Charge Mode Specifications
INVERTER MODELPOW-HVM8.2MPOW-HVM10.2M
Charging Algorithm3-Step
AC Charging Current (Max)140A140A
Max. PV Array Power8200W10200W
Nominal PV Voltage360Vdc360Vdc
PV Array MPPT Voltage Range90Vdc~500Vdc
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)160A160A
Table 4: Grid-Tie Operation
INVERTER MODELPOW-HVM8.2MPOW-HVM10.2M
Nominal Output Voltage220/230/240VAC
Feed-in Grid Voltage Range195-253VAC
Feed-in Grid Frequency Range49-51±1Hz/59-61±1Hz
Nominal Output Current35.6A44.3A
Maximum Conversion Efficiency (DC/AC)98%
Table 5: Two Load Output Power
INVERTER MODELPOW-HVM8.2MPOW-HVM10.2M
Full Load8200W10200W
Maximum Main Load8200W10200W
Maximum Second Load (battery model)2733W3400W
Main Load Cut Off Voltage44VDC44VDC
Main Load Return Voltage54VDC54VDC

4. Setup

4.1 Unboxing and Package Contents

Upon unboxing, verify that all items are present and undamaged. The package typically includes:

  • One (1) PowMr All-in-One Solar Inverter (POW-HVM10.2M)
  • One (1) User Manual
  • One (1) pair of MC4 connectors
  • One (1) grounding terminal

Video 1: Unboxing the PowMr 10.2KW Solar Inverter and reviewing package contents.

4.2 Physical Installation

The inverter is designed for wall mounting. Ensure the installation location provides adequate ventilation to prevent overheating. Avoid direct sunlight, high humidity, and dusty environments. Maintain sufficient clearance around the inverter for airflow and maintenance access.

4.3 Electrical Connections

All electrical connections should be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure the inverter is turned off and disconnected from all power sources before making any connections.

  1. PV Input (PV1, PV2): Connect your solar panel arrays to the designated PV input terminals. The inverter supports a wide PV input voltage range of 90-500Vdc.
  2. Battery Input: Connect the 48V battery bank to the battery input terminals. Ensure correct polarity. The inverter is compatible with various battery types including Lifepo4, Lithium, Flooded, Gel, and Lead-acid.
  3. AC Input (AC In): Connect the utility grid or generator AC power to the AC input terminal.
  4. AC Output (Main Out, Second Out): Connect your loads to the main and second AC output terminals. The inverter offers dual AC output for flexible load management.
  5. Communication Port (COMM): Connect the optional WIFI module or other communication devices to the RS232/WIFI/Remote LCD Communication Port for remote monitoring.
  6. Grounding: Ensure the inverter is properly grounded using the provided grounding terminal.
PowMr Inverter with labeled ports

Figure 3: Labeled ports and indicators on the PowMr Hybrid Solar Inverter.

5. Operating Instructions

5.1 Display and Controls

The inverter features an LCD display and touch function buttons for monitoring and configuration:

  • LCD Display: Shows real-time system status, operational parameters, and error codes.
  • Status Indicator: Provides visual feedback on the inverter's operational state.
  • Charging Indicator: Indicates the battery charging status.
  • Fault Indicator: Illuminates when a system fault is detected.
  • Touch Function Buttons: Used to navigate menus, adjust settings, and confirm selections.
  • Power ON/OFF Switch: Controls the main power to the inverter.

5.2 Multiple Charging and Output Modes

The inverter supports various modes to optimize energy flow based on your needs:

  • Solar Priority: Solar energy is primarily used to power loads and charge batteries.
  • Solar + Utility: Solar energy is prioritized, with utility power supplementing when solar is insufficient.
  • Only Solar: Loads are powered exclusively by solar energy.
  • Utility Priority: Utility power is prioritized, with solar energy used as a backup or to charge batteries.
  • SBU Mode (Solar-Battery-Utility): Solar power is prioritized, then battery power, and finally utility power as a last resort.
Diagram of multiple charging and output modes

Figure 4: Visual representation of the various charging and output modes.

5.3 Remote Monitoring and Control

The inverter can be monitored and controlled remotely via the 'SMARTESS' app, available on the App Store and Google Play. A separate WIFI module and GPRS data are required for this functionality.

Remote monitoring via SMARTESS app

Figure 5: Illustration of remote monitoring and control using the 'SMARTESS' app.

6. Maintenance

Regular maintenance ensures optimal performance and longevity of your inverter. Always disconnect power before performing any maintenance.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure the cooling vents are free from dust and debris. The demountable insect screen can be removed for cleaning.
  • Connection Inspection: Regularly check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion or damage.
  • Environmental Check: Ensure the installation environment remains within specified temperature and humidity ranges. The built-in anti-dust kit helps protect the inverter in harsh environments.
  • Firmware Updates: Check the manufacturer's website or app for any available firmware updates to ensure your inverter has the latest features and bug fixes.
Inverter top-down view showing internal components

Figure 6: Top-down view of the inverter, showing internal connections and cooling fans.

7. Troubleshooting

This section provides guidance on common issues you might encounter. For complex problems, contact technical support.

7.1 Common Issues and Solutions

  • No Power Output: Check AC input, battery connections, and PV input. Ensure the power switch is ON. Verify that no protection features (e.g., overload, over-temperature) have been triggered.
  • Battery Not Charging: Check PV array connections and voltage. Verify AC input if charging from utility. Ensure battery type settings are correct.
  • Inverter Fault Indicator On: Refer to the LCD display for specific error codes. Common faults include over-voltage, under-voltage, over-current, and over-temperature. Address the underlying cause as indicated by the error code.
  • Inverter Not Connecting to Grid: Check grid voltage and frequency. Ensure grid-tie settings are correctly configured according to local utility requirements.

7.2 Frequently Asked Questions (FAQ)

  • Can this product be coupled in parallel? The product description does not explicitly state parallel capability. Please consult the full technical manual or contact PowMr support for information on multi-unit operation.
  • Can it run off-grid solar, wind, and battery? This is a hybrid solar inverter with on/off grid capabilities, meaning it can operate with solar and battery power, and can connect to the grid. It is primarily designed for solar and battery integration.
  • Is it compatible with any type of lithium-ion battery? Will it pick up the type of lithium-ion battery itself? The inverter is compatible with Lifepo4 and Lithium batteries, among others. It features a built-in lithium battery automatic activation function, which helps optimize performance. However, specific battery settings may need manual configuration.

8. User Tips

  • Battery Management: Take advantage of the smart battery charge design to prolong battery life. Ensure your battery type is correctly selected in the inverter settings. The automatic activation for lithium batteries is a convenient feature.
  • Remote Monitoring: Utilize the 'SMARTESS' app for convenient remote monitoring of your system's performance. This allows you to track energy production, consumption, and battery status from anywhere. Remember to purchase the optional WIFI module.
  • Load Distribution: With dual AC outputs, you can distribute your loads efficiently. Consider connecting critical loads to the main output and less critical ones to the second output, especially if you plan to utilize specific power management strategies.
  • Environmental Protection: The built-in anti-dust kit and demountable insect screen are designed to protect your inverter. Regularly clean these components to maintain optimal cooling and prevent internal damage, especially in dusty or insect-prone areas.

9. Safety Information

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

  • Installation must be performed by qualified personnel.
  • Do not attempt to repair the inverter yourself. Refer all servicing to qualified service personnel.
  • Ensure proper grounding of the inverter.
  • Do not operate the inverter in wet conditions or near flammable materials.
  • Keep children away from the inverter.
  • Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your authorized PowMr dealer or visit the official PowMr website. Keep your purchase receipt and product serial number handy for faster service.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.