A-BF RX-500/RX-550

Contents

A-BF RX-500/RX-550 Series Infrared Thermal Imager User Manual

Models: RX-500, RX-550 (also known as HT-18 Plus)

1. Introduction

The A-BF RX-500/RX-550 series are advanced handheld infrared thermal imagers designed for accurate and real-time temperature measurement and thermal analysis. These devices are equipped with a high-resolution infrared sensor and a clear display, making them ideal for various applications including industrial inspections, automotive diagnostics, building maintenance, and fire rescue. This manual provides essential information for the safe and effective operation of your thermal imager.

A-BF RX-500 product overview with key features and package contents

Figure 1: A-BF RX-500 Product Overview

2. Package Contents

Please check the box for the following items:

  • A-BF RX-500/RX-550 Thermal Imager
  • Packaging Box
  • Instruction Manual
  • Data Cable (Type-C USB)
  • Charger
  • Toolkit (for some RX-500 variants)
  • Toolbag (for some RX-550 variants)

3. Product Overview

Familiarize yourself with the main components of your thermal imager:

Detailed diagram of the A-BF RX-500 components

Figure 2: Device Components

  • Cap: Protective cover for the infrared lens.
  • 3.2" Screen: Full-angle TFT display for thermal images and menu navigation.
  • Micro USB / Type-C USB Port: For data communication and charging.
  • Memory: Built-in 4GB eMMC (approximately 3GB user available space) for storing images and videos.
  • Handheld Grip: Ergonomically designed for comfortable use.
  • Auto Focus: Automatically adjusts focus for clear thermal images.
  • Infrared Imaging Sensor: Captures thermal data.
  • Image Capture Key: Button to take photos or record videos.
  • Battery: Dedicated removable rechargeable lithium battery (2200mAh).
  • Control Buttons: Power, Menu, Select, Enter, and navigation arrows for device operation.

4. Setup

4.1. Charging the Battery

Before first use, fully charge the device. Connect the provided data cable to the Type-C USB port on the device and the charger. Plug the charger into a power outlet. The charging indicator on the device will show the charging status.

4.2. Powering On/Off

To power on the device, press and hold the Power button (usually red) until the screen illuminates. To power off, press and hold the Power button again until the device shuts down.

5. Operating Instructions

5.1. Basic Operation

Point the thermal imager at the object you wish to inspect. The thermal image will be displayed on the 3.2-inch screen. The device automatically tracks the highest, lowest, and center temperatures within the field of view.

5.2. Menu Navigation

Use the 'MENU' button to access the main menu. Navigate through options using the arrow buttons (up, down, left, right) and confirm selections with the 'ENTER' button. The 'SELECT' button may be used for quick option changes or sub-menus.

5.3. Color Palettes

The device offers multiple color palettes to visualize temperature differences. You can select the most suitable palette for your application from the menu. Available palettes include:

  • Rainbow
  • Iron Red
  • Cool Color
  • White Heat
  • Black Hot
  • Mix
Illustration of 6 thermal imaging color modes

Figure 3: Thermal Imaging Color Modes

5.4. Emissivity Adjustment

Emissivity is a measure of an object's ability to emit infrared energy. Accurate emissivity settings are crucial for precise temperature readings. The device allows adjustment from 0.01 to 1.00. Common emissivity modes include:

  • Matt (e=0.95)
  • Semi-matte (e=0.85)
  • Semi-glossy (e=0.60)
  • Glossy (e=0.30)
Examples of 4 emissivity modes

Figure 4: Emissivity Modes

5.5. Image and Video Capture

Press the Image Capture Key to take a photo or record a video. Captured media is stored in the device's internal memory. You can review images and videos directly on the device or transfer them to a computer for further analysis.

5.6. PC Software Analysis

The device supports offline analysis using dedicated PC software. Connect the thermal imager to your computer via the Type-C USB cable. Install the provided software (or download from the manufacturer's website) to analyze thermal images and video files in detail.

Diagram showing PC software analysis and video recording function

Figure 5: PC Software Analysis

6. Key Features

  • High and Low Temperature Automatic Tracking: The device automatically identifies and displays the highest, lowest, and center temperatures within the field of view, providing critical data at a glance.
Display showing high and low temperature automatic tracking

Figure 6: Automatic Temperature Tracking

  • Exceptional Thermal Sensitivity: With a thermal sensitivity of 0.07°C, the imager can capture subtle temperature changes, revealing issues invisible to the naked eye.
Diagram illustrating 0.07°C thermal sensitivity

Figure 7: Thermal Sensitivity

  • Wide Field of View (FOV): A 56°x42° field of view allows for comprehensive scanning of large areas, ensuring no hidden corners are missed.
Diagram showing the wide 56x42 degree field of view

Figure 8: Wide Field of View

  • Crisp & Clear Image Results: Delivers 256x192 resolution, 49152-pixel infrared images for detailed thermal analysis.
Image demonstrating crisp and clear 256x192 infrared image resolution

Figure 9: Crisp Image Resolution

7. Applications

The A-BF RX-500/RX-550 thermal imager is a versatile tool suitable for a wide range of professional and home applications:

  • Car Inspections: Pinpoint electrical issues, heated seats, window heating, and brake system defects.
  • Heat Leaks: Identify insulation problems and energy inefficiencies in buildings.
  • Fire Rescue: Assist in locating hot spots and victims in smoke-filled environments.
  • Home Maintenance: Detect plumbing leaks, electrical overloads, and HVAC issues.
Visual examples of various applications for the thermal imager

Figure 10: Diverse Applications

8. Specifications

FeatureSpecification
ModelRX-500 / RX-550 (HT-18 Plus)
Infrared Resolution256x192 Pixels
Visible Light Resolution640x480 Pixels
Display Size3.2 Inches Full Angle TFT Screen
Temperature Range-20°C to +550°C (-4°F to 1022°F)
Accuracy(-15℃~+550℃) ±2℃ or ±2%; (-20℃~-15℃) ±4℃ or ±4%
Thermal Sensitivity (NETD)<50mK (0.07°C)
Frame Rate≤25Hz
Wavelength Coverage8μm-14μm
Field of View (FOV)56°x42°
IFOV3.75mrad
Focus ModeAuto Focus
Shortest Focus Length3.2mm
Measuring Distance0.2m-40m (best 1m)
Color PalettesRainbow, Iron Red, Cool Color, White Heat, Black Hot, Mix
EmissivityAdjustable from 0.01 to 1.00 (Matt, Semi-matte, Semi-glossy, Glossy modes)
Temperature Unit°C/°F Switch
High/Low Temp AlarmYes
Image/Video StorageBuilt-in 4G eMMC (approx. 3GB user available)
Data CommunicationType-C USB
PC Software AnalysisSupport offline analysis on PC
Battery TypeDedicated removable rechargeable lithium battery
Battery Capacity2200mAh
Working Time2-3 hours (Continuous)
Product Size90mm x 105mm x 223mm
Weight389g
Smart DeviceYes
CertificationCE
Menu LanguageEnglish/Chinese/Italian/German
Comparison table between RX-500 and UTi260B thermal imagers

Figure 11: RX-500 vs. UTi260B Comparison

9. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device body. For the lens, use a lens cleaning cloth and solution specifically designed for optics. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Ensure the lens cap is on when not in use.
  • Battery Care: For optimal battery life, avoid fully discharging the battery frequently. If storing for extended periods, charge the battery to about 50% and recharge every few months.

10. Troubleshooting

  • Device does not power on: Ensure the battery is sufficiently charged. Connect the device to the charger and try again. If the issue persists, contact support.
  • Image is blurry: Check if the lens cap is removed. Ensure the auto-focus feature is working correctly. Clean the lens if necessary.
  • Inaccurate temperature readings: Verify that the emissivity setting is appropriate for the material being measured. Ensure the measurement distance is within the recommended range (best at 1m).
  • Device unresponsive: Try performing a soft reset by holding down the power button for an extended period (e.g., 10-15 seconds) until the device restarts or shuts down.

11. User Tips

  • Date Display: If you wish to have the date appear alongside your captured images, navigate through the device's settings menu. Look for options related to 'Display Settings' or 'Image Overlays' to enable this feature.
  • Software Updates: Periodically check the manufacturer's website for any available firmware updates for your device or updates to the PC analysis software to ensure optimal performance and access to new features.

12. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official A-BF website. Keep your proof of purchase for warranty claims.

13. Product Demonstration Video

This video demonstrates the A-BF RX-500 thermal imager in use, showcasing its features and various applications.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.