1. Introduction
The COMPTYCO AUA28A/28U is a state-of-the-art multifunctional Optical Time Domain Reflectometer (OTDR) designed for comprehensive testing and maintenance of fiber optic communication networks. This device integrates multiple essential functions including OTDR, Visual Fault Locator (VFL), Optical Power Meter (OPM), and Optical Light Source (OLS into a single, portable unit.
An Optical Time Domain Reflectometer (OTDR) is a core detection equipment for the construction, operation, and troubleshooting of fiber optic communication networks. It works based on the principles of backward scattering and Fresnel reflection of light. The device emits light pulses to the tested optical fiber. During the propagation of light in the fiber, reverse light signals are generated due to Rayleigh scattering of the fiber itself, Fresnel reflection at joints or breakpoints. OTDR receives and analyzes these signals, and by calculating the round-trip time of the light pulse and combining it with the propagation speed of light in the fiber, it can accurately locate fiber fault points, measure link attenuation, evaluate joint quality, etc. It is an essential tool for fiber optic cable construction acceptance and daily maintenance.
Key features include a high-definition touch screen, support for active fiber testing, a 60km test distance, 10mW VFL, and quick boot-up in just 2 seconds.
Figure 1: AUA28A/28U Multifunctional OTDR highlighting key specifications for AUA28A (APC Port) and AUA28U (UPC Port).
2. Product Components and Physical Overview
2.1. Product List
The standard package for your AUA28A/28U OTDR includes the following items:
- Mainframe (OTDR device)
- Charger
- Instrument bag
- Back strap
- OTDR SC adapter
- OPM SC adapter
- Instruction manual
- CD-ROM
- USB data cable
- Cotton swab
- Packing box
Figure 2: Contents of the AUA28A/28U package.
2.2. Device Overview
Familiarize yourself with the various ports, buttons, and display areas of your OTDR device:
Figure 3: Front and bottom view of the OTDR device with labeled components.
- OTDR/OLS Port: For Optical Time Domain Reflectometer and Optical Light Source functions.
- OPM Port: For Optical Power Meter function.
- VFL Port: For Visual Fault Locator function.
- Charging Port: Connect the charger here.
- Data Transfer Port: For connecting to a computer.
- LCD Display Area: High-definition touch screen for operation and viewing results.
- Soft Keys (F1-F4): Context-sensitive function keys.
- Direction Selection Keys: For navigation.
- OK/Confirm Button: To confirm selections.
- ESC/Cancel Button: To go back or cancel an operation.
- Shutdown Key: Power on/off the device.
- Keyboard Input Area: For entering data.
2.3. Standard Interfaces and Adapters
The OTDR and OPM ports support SC/FC adapters. The VFL is applicable to a 2.5mm interface.
Figure 4: Standard interface types and compatible adapters (SC/APC, FC/APC, OTDR SC, OPM SC).
3. Setup and Initial Use
3.1. Charging the Device
The device is equipped with a 4400mAh large capacity lithium battery. To charge:
- Connect the provided charger to the device's charging port.
- Plug the charger into a suitable power outlet (American Standard or European Standard options available).
- Ensure the device is charging. The charging indicator light will typically show the charging status.
Figure 5: Battery compartment and charger connection point.
3.2. Powering On/Off
Press and hold the Shutdown Key (usually marked with a power symbol) to power the device on or off. The device features a quick boot time of approximately 2 seconds.
3.3. Language Selection
The device supports bi-lingual switching between English and Spanish. This option can typically be found in the 'Settings' menu on the touch screen interface.
4. Operating Instructions
The AUA28A/28U features an LCD high-definition touch screen combined with physical keys for convenient operation.
Video 1: Product demonstration showing the device's interface, adapter interchangeability, and functions like OTDR, VFL, OPM, and OLS.
4.1. OTDR Test Function
The OTDR function is used to measure fiber length, detect faults, and analyze attenuation. The device supports a test distance of up to 60km.
- Connect the fiber to be tested to the OTDR port using the appropriate SC/FC adapter.
- From the main menu, select the 'OTDR' icon.
- Configure test parameters such as wavelength, pulse width, and range as needed.
- Press 'Test' to begin the measurement. The device will display the trace curve and event list.
- Results can be saved in .Sor format and reports can be printed.
4.2. Visual Fault Locator (VFL) Function
The VFL function helps locate breaks, bends, and poor connections in fiber optic cables by emitting a visible red laser light.
- Connect the fiber to the VFL port (2.5mm interface).
- From the main menu, select the 'VFL' icon.
- Choose the desired mode (CW, 1Hz, 2Hz) using the soft keys.
- Observe the fiber for any visible light leakage, indicating a fault.
4.3. Optical Power Meter (OPM) Function
The OPM measures the optical power of a fiber optic signal. It supports 6 kinds of wavelengths.
- Connect the fiber to the OPM port using the appropriate SC/FC adapter.
- From the main menu, select the 'OPM' icon.
- Select the appropriate wavelength (e.g., 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1610nm) using the navigation keys.
- The device will display the measured optical power in dBm and nW.
4.4. Optical Light Source (OLS) Function
The OLS provides a stable light source for testing fiber optic cables, typically at 1550nm.
- Connect the fiber to the OLS port (shared with OTDR port).
- From the main menu, select the 'OLS' icon.
- Select the desired wavelength (e.g., 1550nm) and modulation frequency (CW, 270Hz, 1kHz, 2kHz).
- The device will emit a stable light signal for testing.
5. Maintenance
5.1. Cleaning
Regular cleaning of the OTDR and VFL functions is crucial for accurate measurements. Use the provided cotton swab or a suitable fiber optic cleaning tool to clean the optical ports before and after each use. Ensure the device is powered off during cleaning.
5.2. Battery Care
To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, especially if it will be stored for an extended period. Use only the charger supplied with the device.
5.3. Storage
Store the device in its instrument bag in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure all ports are covered to prevent dust ingress.
6. Troubleshooting
6.1. General Issues
- Device not powering on: Ensure the battery is charged. Connect the charger and try again.
- Inaccurate measurements: Clean all fiber optic connectors and ports thoroughly. Ensure correct test parameters are selected.
- No VFL light: Check if the VFL function is activated and the fiber is properly connected.
6.2. Laser Safety
WARNING: Invisible Laser Radiation. Avoid exposure to beam. Do not look directly at the laser. Class 1M Laser Product.
Always exercise caution when using the VFL and OLS functions. Never look directly into the optical output ports or into a fiber connected to the device when the laser is active. Use appropriate eye protection if necessary.
7. Specifications
Figure 6: Detailed technical specifications.
| Category | Parameter | Value |
|---|---|---|
| OTDR | Wavelength (nm) | 1310/1550 (24/22), 1310/1550 (26/24), 1550 (20), 1610 (20) |
| Dynamic Range (dB) | 24/22, 26/24, 20, 20 | |
| Active Test | no, no, yes, yes | |
| Measurement Distance | 0-60 km | |
| Type of Fiber | 9/125um SM | |
| Type of Connectors | FC/PC; SC/PC (FC/APC SC/APC - Optional) | |
| Peak Value of laser | >=30mW | |
| Unit | Meter/ inch/ mile | |
| Dead Zone of Reflection | 2m | |
| Dead Zone of Attenuation Event | 12m | |
| Accuracy Distance (Reflection Event) | About ±(1m+2 * 10^(-4) * distance) | |
| Storage of records | 200 groups | |
| Visual Fault Locator (VFL) | Wavelength (nm) | 650nm |
| Output power | >=10mW | |
| Mode | CW, 1Hz, 2Hz | |
| Fiber type | SM, MM | |
| Optical Power Meter | Measurement range dBm | -70 ~ +10 dBm, -50 ~ +26 dBm |
| Wavelength Range (nm) | 800 ~ 1650 | |
| Calibrated wavelength | 850, 1300, 1310, 1490, 1550, 1625 | |
| Detector | InGaAs | |
| Accuracy | ±3% (>-10dBm, 22℃) | |
| Resolution | Linearity: 0.1%, Non-linearity: 0.01dBm | |
| Optical Light Source | Connector | Changeable FC/PC SC/PC, (ST as Optional) |
| Emitter | FP-LD | |
| Wavelength (nm) | 1310/1550 (28U, 28A), 1550 (28U, 28A), 1610 (216U, 216A) | |
| Connector | FC/PC (SC/ST as optional) | |
| Output power | >=5dBm | |
| Output stability (dBm) | ±0.04@20℃ @15min | |
| Modulation | CW/270Hz/1KHz/2KHz | |
| Fiber type | SM | |
| Others | LCD | 3.97inch, 800*480pixels, IPS screen |
| Battery | 7.4V/4400mAh Lithium-ion battery, >5000 tests | |
| Temperature | Work temperature: -5 ~ 50 ℃, storage temperature: -10 ~ 60 ℃ | |
| Humidity | 0 ~ 85% (Non-condensing) | |
| Dimensions (mm) | 190×84×52 | |
| Weight (g) | 375 |
8. User Tips
- Regular Cleaning: Always clean fiber connectors and ports before each use to ensure accurate readings and prevent damage.
- Adapter Compatibility: Ensure you use the correct SC/FC adapters for OTDR/OPM and the 2.5mm interface for VFL to avoid connection issues.
- Battery Management: For optimal battery life, avoid letting the device fully discharge frequently. Charge it when the battery level is low.
- Data Storage: Utilize the device's data saving feature to store test results in .Sor format for later analysis and reporting.
- Language Setting: If the interface language is not preferred, navigate to the 'Settings' menu to switch between English and Spanish.
9. Warranty and Support
For detailed warranty information, please refer to the official documentation provided with your product or contact the manufacturer directly. For technical support or service inquiries, please reach out to your vendor or the COMPTYCO customer service.
A user manual in PDF format is available for download and further reference. You can access it via the following link: AUA28A/28U User Manual (PDF).