Thank you for purchasing the RIDEN RD6006 Digital Control DC Power Supply. This manual provides detailed instructions for the proper use and maintenance of your device. Please read it carefully before operation and keep it for future reference.

RIDEN RD6006 Digital Control DC Power Supply front view
Figure 1: RIDEN RD6006 Digital Control DC Power Supply (Assembled Set)

1.1 Key Features

  • Output Voltage: 60V
  • Output Current: 6A
  • Output Power: 360W
  • Display: 2.4-inch color HD display
  • Control: Digital Keypad + Encoder Potentiometer
  • Protection: Multiple protection features including Over-Voltage (OVP), Over-Current (OCP), and Over-Temperature (OTP).
  • Connectivity: USB interface for PC software control. (WiFi and Clock Battery CR1220 not included in this assembled set, must be purchased separately).
  • Data Management: Data group storage and call-out functions.
  • Firmware: Supports firmware upgrades.

2. Setup

2.1 Accessory List

The RD6006 assembled set comes with the following accessories:

Complete accessories for RD6006, including power supply, cables, and sensor
Figure 2: Complete Accessories
  • RD Power Supply x1
  • X25A Output Cable x1
  • Input AC Power Cord x1 (AC cord type prevails based on region)
  • Micro Communication Cable x1 (inside X25A bag)
  • External Temperature Sensor x1
  • Backup Fuse x1

2.2 Initial Connection

This set is already assembled. You can connect the AC power directly. The only difference between the available choices (US/EU/UK/AU Plug) is the AC cable and input AC voltage request. Other components are the same.

Note: This set does not include a WiFi card for APP connection or a CR1220 battery for date/time display. If you wish to use the WiFi function, you need to order the WiFi board separately. If you install the WiFi card, you must install the battery first, as you cannot remove the WiFi card to install the battery later. The WiFi board link is: https://www.aliexpress.com/item/4000478822325.html

2.3 Product Interface and Back Display

Product back display showing internal components like fan, temperature sensor, WiFi communication board, and clock battery socket
Figure 3: Product Back Display (showing Temperature Sensor, WiFi Communication Board, Clock Battery Socket)

The back panel includes connections for the input power socket, external temperature sensor, and features a rocker switch and heat dissipation holes. Internally, it houses the WiFi communication board socket and a clock battery socket (for CR1220 battery, not included).

Front panel of RD6006 showing digital keypad, encoder potentiometer, and output terminals
Figure 4: Front Panel Controls (Digital Keypad + Encoder Potentiometer)

The front panel features a 2.4-inch color HD display, a digital keypad, an encoder potentiometer for precise adjustments, and various buttons for control (SHIFT, MEM, I-SET, V-SET, ON/OFF, MENU, LOCK, ENTER). It also includes a breathing light, USB interface, and battery charging terminals.

3. Operating Instructions

3.1 Main Page and Basic Operation

After powering on, the device will display a boot image, then enter the main operating page. You can navigate and adjust settings using the digital keypad, encoder potentiometer, and various function buttons.

RD6006 display styles: Classic, Detailed, and Curve
Figure 5: Main Page Display Styles

Press the ◄ ► buttons to cycle through display styles: Traditional, Detail, and Curve. The selected style will not be saved automatically unless set as default in the System Settings.

3.2 Output Voltage and Current Setting

Use the V-SET button to set the output voltage and the I-SET button to set the output current. Rotate the encoder potentiometer to adjust values or use the keypad for direct input. Press ENTER to confirm. If a value exceeds the limit, an error message will be displayed.

3.3 Protection Settings (OVP, OCP, OTP)

The device features multiple protection mechanisms:

  • Over-Voltage Protection (OVP): Set the maximum output voltage. If the actual output voltage exceeds this value, the power supply will automatically stop output.
  • Over-Current Protection (OCP): Set the maximum output current. If the actual output current exceeds this value, the power supply will automatically stop output.
  • Over-Temperature Protection (OTP): If the system temperature exceeds 80°C, the output will automatically stop.

To set OCP/OVP values, press SHIFT + I-SET or SHIFT + V-SET. The operation is similar to setting output current/voltage. For OCP to function as an auto cut-off, the OCP value must be lower than the current setting value.

3.4 Data Group Storage and Call Out

The device allows you to store and recall up to 10 sets of voltage, current, OCP, and OVP values.

RD6006 display showing data storage and call out functions
Figure 6: Data Storage and Call Out

Press MEM + keypad button (1-9) to store the current settings. Press SHIFT + keypad button (1-9) to recall saved data. The default data group is M0.

3.5 Keypad Lock and Unlock

Press SHIFT + LOCK to lock or unlock the keypad. The keypad will automatically lock when communication starts and unlock after 3 seconds of disconnection.

3.6 System Settings

Access system settings by pressing SHIFT + 0. Use direction buttons and the encoder potentiometer to navigate and adjust settings such as Language, Boot Power, Boot Logo, Buzzer, Backlight, Update Rate, Max Power, Temperature Unit, Cut-Off Current, Cut-Off Temp, Communication Interface (USB, WIFI, TTL, RS485), Date and Time, and Main Page Display Style.

3.7 Mobile APP Control (Optional, requires WiFi board)

Mobile app interface for controlling RD6006 via WiFi
Figure 7: Mobile APP Control Interface

If you have installed the optional WiFi board, you can control the RD6006 via a mobile app (Android/iOS). Download the app from the respective app stores or the provided links in the full PDF manual. Ensure your mobile phone and the RD6006 are connected to the same 2.4G WiFi network. The app allows monitoring and setting of parameters remotely.

3.8 PC Software Control

PC software interface for controlling RD6006
Figure 8: PC Software Control Interface

The RD6006 can be controlled via PC software (Windows 7 or above) using a USB connection. The software provides comprehensive functions including voltage/current preset, data group management, calibration, brightness settings, and real-time voltage/current curve display. Download the PC software from the official website or the links provided in the full PDF manual. Ensure the correct drivers are installed for USB communication.

4. Maintenance

4.1 Firmware Upgrade

To ensure optimal performance and access to the latest features, it is recommended to keep the device firmware updated. Firmware upgrades can be performed via the PC software.

Video 1: Product Overview and Firmware Upgrade Demonstration

Connect the RD6006 to your PC via Micro USB. In the PC software, navigate to the Firmware Update section. Follow the on-screen instructions to update the firmware. Ensure the device is in boot mode if a normal startup is not possible.

4.2 Boot Logo Update

The PC software also allows you to update the boot logo of the device. Select a picture from your computer and follow the software's instructions to apply it.

4.3 General Care

  • Keep the device clean and free from dust.
  • Do not expose the device to extreme temperatures or humidity.
  • Do not remove the shell of the PSU for better heat dissipation. Removing the shell can lead to insufficient heat dissipation and damage to components, voiding the warranty.

5. Troubleshooting

5.1 PSU Noise

Issue: High-frequency noise when the switching power supply is unloaded or loud fan noise.

Solution: These are normal phenomena. Due to the large output power range, the PWM control chip may jump control cycles to reduce power consumption, which can produce audible noise. Fan noise occurs when the ambient temperature is high. It is recommended to turn off the AC switch when the product is not in use if you find the noise bothersome.

5.2 APP/PC Software Connection Issues

Issue: APP crashes, or unable to connect RD6006 to phone APP via WiFi or PC via WiFi.

Solution:

  • Ensure the optional WiFi board is properly inserted.
  • Verify your WiFi network is 2.4GHz.
  • Disable client isolation/AP isolation and WMM functions on your router.
  • Ensure location and storage services are enabled for the APP during installation.
  • PC WiFi connection is a test function and may have compatibility issues with some computers. If PC WiFi connection fails, use USB connection.

5.3 Physical Appearance Concerns

Issue: Scratches on the PSU or traces on the panel.

Solution: Minor scratches on the PSU surface or slight traces at the button holes due to the injection molding process are normal and do not affect product performance. These are not considered defects.

Example of minor scratches on PSU casing
Figure 9: Example of PSU Scratches
Example of slight traces on the panel from injection molding
Figure 10: Example of Panel Traces

5.4 Inductive Load Usage

Issue: Using the device with inductive loads (e.g., motors).

Solution: If connecting an inductive load, the maximum working voltage and current should not exceed 1/3 of the full range of the power supply.

6. Specifications

ParameterValue
ModelRD6006 assembled set
Input Voltage Range100-120V/200-240V AC
Output Voltage Range0-60.00V
Output Current Range0-6.000A
Output Power Range0-360W
Input Voltage Measurement Resolution0.01V
Output Voltage Setting Measurement Resolution0.01V
Output Current Setting Measurement Resolution0.001A
Battery Voltage Measurement Resolution0.01V
Input Voltage Measurement Accuracy±(1%+5 digits)
Output Voltage Accuracy (Setting vs. Measurement)±(0.3%+3 digits)
Output Current Accuracy (Setting vs. Measurement)±(0.5%+5 digits)
Battery Voltage Measurement Accuracy±(0.5%+3 digits)
Automatic Cut-off Current (Charging)10mA
Output Ripple Typical100mV VPP
Working Temperature Range-10℃~40℃
External Sensor Temperature Detection Range-10℃~100℃/0℉~200℉
External Sensor Temperature Detection Accuracy±3℃/±6℉
Constant Voltage Mode Response Time2ms (0.1A-5A Load)
Constant Voltage Mode Load Regulation±(0.1%+2 digits)
Constant Current Mode Load Regulation±(0.1%+3 digits)
Capacity Measurement Range0-9999.99Ah
Energy Measurement Range0-9999.99Wh
Capacity and Energy Statistical Error±2%
Buck Working ModeVoltage drop >1V and >10%
Over Temperature ProtectionSystem temperature>80℃
Screen Brightness Setting0-5 (6 levels in total)
Screen2.4-inch color HD display
Cooling Fan Start ConditionOutput voltage>40V or Output current>4A or System temperature>45℃
Cooling Fan Shut Down ConditionOutput voltage<40V and Output current<3.9A and System temperature<45℃
Product Dimension173*92*336mm

7. User Tips

  • Battery Charging: It is strongly recommended to use the original charger for battery charging. The charging function of this machine is for temporary replacement only. Understand your battery parameters well to avoid risks.
  • Inductive Loads: When connecting inductive loads (such as motors), ensure the maximum working voltage and current do not exceed 1/3 of the power supply's full range.
  • Device Integrity: Do not remove the shell of the PSU. Removing the shell alters the heat dissipation system, leading to insufficient cooling and potential damage to components. This will void the warranty.
  • WiFi Board Installation: If you plan to install the optional WiFi board, ensure you install the CR1220 clock battery first. Once the WiFi board is installed, it cannot be easily removed to install the battery.

8. Warranty and Support

For the full instruction manual, PC software, and video tutorials, please refer to the official download link: RIDEN RD6006 Instruction Manual & Software

If you receive a Power Supply Unit (PSU) and suspect damage, use a multimeter to check the output voltage stability before connecting it to the RD power supply to prevent further damage.

PSU notification image
Figure 11: PSU Notification

For technical support or inquiries, please refer to the contact information provided in the official manual or contact the seller directly.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.