Yieryi WIFI-3188

Contents

Yieryi WiFi Tuya Smart Water Quality Monitor Instruction Manual

Model: WIFI-3188

1. Introduction

The Yieryi WiFi Tuya Smart Monitor is an advanced online water quality meter designed for comprehensive monitoring of various water parameters. This device allows simultaneous measurement of pH, ORP, EC, PPM, CF, Humidity, and Temperature. With its intelligent real-time data transmission via WiFi and the Tuya Smart APP, you can conveniently view current and historical data, set alarms for abnormal high and low readings, and manage your water environment from your mobile phone. This manual provides detailed instructions for the proper setup, operation, and maintenance of your water quality monitor.

Yieryi WiFi Tuya Smart Monitor showing pH, EC, and Temperature readings with a connected smartphone displaying app data.
Figure 1: Yieryi WiFi Tuya Smart Monitor in operation with mobile app connectivity.

2. Safety Information

  • Read all instructions carefully before using the device.
  • This tester is NOT waterproof. Do not immerse the main unit in water or allow it to get wet during use. Doing so may cause malfunction or damage.
  • Keep the device away from children and pets.
  • Use only the provided power adapter.
  • Do not attempt to disassemble or repair the device yourself. Contact customer service for assistance.
  • Ensure proper ventilation when operating the device.
Yieryi WiFi Tuya Smart Monitor with a clear 'Not Waterproof' warning over the main unit.
Figure 2: Important warning: The main unit of the tester is not waterproof.

3. Package Contents

Verify that all items are present and in good condition upon unpacking:

  • 1 x Tuya Smart WiFi Online PH ORP EC PPM CF Humidity Temperature Controller (Main Unit)
  • 1 x Multi-parameter Electrode Probe
  • 1 x Power Adapter (EU Plug Type)
  • 1 x User Manual (English)
Contents of the Yieryi WiFi Tuya Smart Monitor package, including the main unit, probe, power adapter, and user manual.
Figure 3: Package contents of the water quality monitor.

4. Specifications

ParameterValue
Model NumberWIFI-3188
Brand NameYieryi
Display TypeDIGITAL
BacklightYes
Smart DeviceYes (Tuya App compatible)
CertificationCE
OriginMainland China
MaterialABS
pH Range0.01 - 14.00 pH
ORP Range-1200mV ~ +1200mV
EC Range0.00 - 19.00 mS/cm, 20.1 - 200.0 mS/cm
TDS Range0 - 9990 ppm, 10.1 - 100 ppt
CF Range0.1 - 199.9 CF
Humidity Range01% RH - 99% RH
Temperature Range0.1°C - 80.0°C (32.1°F - 176°F)
Power Line Length95 cm
Probe Wire Length120 cm
Main Unit Dimensions150mm x 80mm
Package Weight0.65 kg
Package Dimensions35cm x 20cm x 8cm
Diagram showing the dimensions of the main unit (150mm x 80mm) and the lengths of the power cable (95cm) and probe cable (120cm).
Figure 4: Device dimensions and cable lengths.

5. Setup

5.1 Initial Device Connection

  1. Unpack all components and ensure they are intact.
  2. Connect the multi-parameter electrode probe to the main unit. Ensure the connection is secure.
  3. Plug the power adapter into the main unit and then into a suitable power outlet. The device LCD screen should light up.

5.2 Tuya Smart App Installation and WiFi Connection

The device requires the Tuya Smart App for intelligent features and data monitoring.

  1. Download the "Tuya Smart" app from your mobile phone's app store (compatible with iOS and Android systems).
  2. Register or log in to your Tuya Smart account.
  3. Open the app and follow the on-screen instructions to add a new device. The app should automatically detect the water quality monitor when it's powered on and in pairing mode.
  4. Enter your WiFi network details (SSID and password) when prompted. Ensure your device is connected to a 2.4GHz WiFi network.
  5. Once connected, the app will display the device's readings and allow access to historical data and alarm settings.
Video 1: Demonstrates the process of connecting the Yieryi Smart Monitor to the Tuya Smart App via WiFi.
Hand holding the Yieryi Smart Monitor with its probe immersed in water, showing the Tuya Smart app on a smartphone with 'Wifi connection / stable data transfer' text.
Figure 5: Device showing WiFi connection and data transfer to the Tuya Smart App.
Multiple smartphone screens displaying the Tuya Smart App interface with real-time water quality data and historical graphs.
Figure 6: Real-time data viewing and historical records within the Tuya Smart App.

6. Operation

6.1 Taking Measurements

  1. Ensure the device is properly set up and connected.
  2. Immerse the electrode probe into the water sample you wish to test. Ensure the probe is fully submerged.
  3. Wait a few seconds for the readings to stabilize on the LCD screen. The device provides a 1-second quick response.
  4. The device will simultaneously display readings for EC/PPM/CF, pH/ORP, and Temperature/Humidity.

6.2 Switching Measurement Modes and Units

The device features buttons for switching between different measurement modes and temperature units:

  • MODE (EC/PPM/CF): Press the 'MODE' button under the EC/PPM/CF display to cycle between Electrical Conductivity (EC), Parts Per Million (PPM), and Conductivity Factor (CF).
  • MODE (pH/ORP): Press the 'MODE' button under the pH/ORP display to switch between pH and Oxidation-Reduction Potential (ORP) readings.
  • °C/°F (TEMP/Humidity): Press the '°C/°F' button under the Temperature/Humidity display to toggle between Celsius (°C) and Fahrenheit (°F) temperature units.
  • ON/OFF (Backlight): Use the ON/OFF button to control the backlight for improved readability in various lighting conditions.
Yieryi Smart Monitor showing the three mode switching buttons for EC/PPM/CF, pH/ORP, and °C/°F.
Figure 7: Mode switching options for various parameters and temperature units.

6.3 Understanding Readings

Refer to the following guidelines for interpreting your water quality readings:

  • pH Reference: Tap water national standard is typically 6.5-8.5 pH.
  • ORP Values: Drinking water: +150-550mV; Mariculture: +300-450mV; Swimming pool: ≥+650mV.
  • TDS (PPM) Water Quality: 0-50 ppm (Ideal drinking water), 50-100 ppm (Activated carbon filtered water), 100-200 ppm (Hard water), 200-400 ppm (Ordinary tap water), 400-500 ppm (Mineral water), 500+ ppm (Not recommended for drinking).
  • CF (Conductivity Factor): Relevant for soilless cultivation, where different crops require specific nutrient solution formulas within the 0.1-199.9 CF range.
PH reference chart showing a scale from 0 to 14, indicating acidic, neutral, and alkalinity levels.
Figure 8: pH reference scale.
ORP value ranges for drinking water, mariculture, and swimming pools.
Figure 9: ORP value guidelines for different water types.
TDS (PPM) water quality chart indicating ideal, filtered, hard, ordinary, mineral, and not recommended for drinking water types.
Figure 10: TDS (PPM) water quality chart.
Yieryi Smart Monitor measuring water in a hydroponic setup, highlighting the CF range and its relevance to nutrient solutions.
Figure 11: CF measurement for nutrient solutions in soilless cultivation.

7. Calibration

To ensure accurate readings, regular calibration of the pH, ORP, EC, and TDS sensors is recommended. The device features a 'CAL' button next to the EC/PPM/CF and pH/ORP displays, indicating a calibration function.

Note: Calibration solutions for ORP, EC, and TDS are not included in the package and must be purchased separately. Please refer to the specific instructions provided with your calibration solutions for the correct procedure. Typically, calibration involves immersing the probe in a known standard solution and adjusting the device to match the standard's value.

8. Maintenance

8.1 Electrode Care

  • Always rinse the electrode probe with distilled water after each use to prevent contamination and ensure accurate future readings.
  • Store the electrode probe in a suitable storage solution (e.g., KCL solution) when not in use to keep the sensor hydrated. Do not store dry.
  • The electrode is removable and can be replaced if damaged or worn out.
Close-up of the removable electrode probe, highlighting its connection point and the seven types of values it can measure.
Figure 12: Multifunctional and removable electrode probe.

8.2 Cleaning the Main Unit

  • Wipe the main unit with a soft, dry cloth.
  • Do not use abrasive cleaners or solvents.
  • As stated in the safety section, the main unit is not waterproof. Avoid any contact with liquids.

8.3 Storage

  • Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Ensure the electrode probe is properly stored in its solution.

9. Troubleshooting

ProblemPossible CauseSolution
Device does not power onPower adapter not connected or faulty; Power outlet issue.Check power connections. Try a different power outlet. Ensure the power adapter is functioning.
Cannot connect to Tuya App / WiFi connection failsIncorrect WiFi password; Device too far from router; Router is 5GHz only; App pairing issue.Ensure correct WiFi password. Move device closer to router. Confirm router supports 2.4GHz WiFi. Restart device and app, then try pairing again. Refer to the app's connection guide.
Inaccurate or unstable readingsElectrode dirty or damaged; Calibration needed; Interference.Clean the electrode thoroughly. Perform calibration using fresh standard solutions. Ensure no strong electromagnetic interference nearby.
Display shows '---' or error codesSensor out of range; Malfunction.Ensure the water parameter is within the device's measurable range. If the issue persists, contact customer service.

10. User Tips

  • Calibration Solutions: Remember that calibration solutions for ORP, EC, and TDS are not included and need to be purchased separately to maintain measurement accuracy.
  • Waterproof Warning: Always be mindful that the main unit of the device is not waterproof. Exercise caution to prevent water exposure.
  • App Connectivity: If you encounter issues connecting to the Tuya app, double-check your WiFi password and ensure your router is broadcasting a 2.4GHz signal, as 5GHz networks are often not supported by smart home devices.
  • Sensor Longevity: Proper storage of the electrode in a suitable solution (e.g., KCL) is crucial for its lifespan and consistent performance.

11. Warranty and Support

The Yieryi brand is committed to providing quality products. All products undergo testing and calibration to ensure qualification before being released to the market.

For any abnormalities, technical support, or service inquiries, please contact Yieryi customer service. Refer to the contact information provided with your purchase or on the official Yieryi website.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.