1. Introduction
The LILYTECH ZL-7928A is an intelligent, safe, and stable temperature and humidity controller designed for incubators, climate chambers, and warehouses. It offers convenient operation and supports various power supply configurations and multi-output voltage options.
Key features include:
- Supports 100/220Vac and/or 12/24Vdc power supply.
- Outputs can operate at different voltages (110V/220Vac, 12V/24Vdc).
- Optional full battery backup system for scenarios with frequent power loss or alternative energy sources (solar, wind).
- Capable of driving incubators of any size.
Video: LILYTECH ZL-7928A Product Overview, showing the device rotating to display its front panel and rear wiring terminals.

Image: Front view of the ZL-7928A controller with a chick, highlighting power supply options (110/220Vac + 12/24Vdc backup) and output voltages.
2. Specifications
| Parameter | Description |
|---|---|
| Power Supply | 100~240Vac, 50/60Hz, and/or 11~26Vdc. 110/220Vac is primary, 12/24Vdc is backup. |
| Power Consumption | 3W |
| Sensors | One temperature sensor (L=2m), one humidity sensor (L=2m). |
| Display Range | Humidity: 0~99% RH; Temperature: -9.9~99℃. |
| Measuring Accuracy | Humidity: ±3%@25°C; Temperature: ±1%@25°C. |
| Output Control | Main-heater, Aux-heater, Lamp, Humidity, Egg-right-turning, Egg-left-turning, Fan. |
| Output Load (Rated) | Main-heater & Aux-heater: 10A; Lamp, Humidity, Egg-turning & Fan: 5A. |
| Hatched Day Counter | Max. 99 days. |
| Egg Turn Control | Period: 1~999 min; Driving Time: 0~999 sec; Turn Times Counter: 0~999 times. |
| Air Exhaustion Control | Period: 1~999 min; Exhausting Time: 0~999 sec. |
| Lamp Control | Period: 1~999 min; Illuminating Time: 0~999 sec. |
| Operation Environment | -10~45°C, less than 90% RH without dew. |
| Device Dimension | 160 * 80 * 95 mm. |
| Installation Drilling Size | 151.5 * 76.5 mm. |

Image: Sensor options ZL-SHr05A (Range: 0-80%RH) and ZL-SHr05B (Range: 0-99%RH).
3. Setup and Wiring
The device is shipped with factory default settings suitable for normal hatching. For specific needs, parameters can be adjusted. Always refer to the wiring diagrams carefully before connecting the device.
Wiring Diagram

Image: Simplified wiring diagram for ZL-7928A, illustrating connections for power, sensors, and outputs.

Image: Application 1 wiring diagram, showing 110/220Vac main power with 12Vdc backup.

Image: Application 2 wiring diagram, showing a 12Vdc power supply.
Connecting to Larger Heaters
For larger incubators requiring more heating energy, the controller's HEAT1/HEAT2 outputs can drive external components in parallel. These components then drive the heaters.
- For 110/220Vac heaters:
- Controller PIN14 supplies 110/220Vac.
- Component input is 110/220Vac.
- Compatible components: SSR-40AA, Magnetic contactor, Relay (e.g., JQX-38F xx0VAC).
- For 12Vdc heaters:
- Controller PIN14 supplies 12Vdc.
- Component input is 12Vdc.
- Compatible components: SSR-40DA, Relay (e.g., JQX-38F 12VDC).
- For 12/24VDC heaters:
- Controller PIN14 supplies DC.
- Component input is DC.
- Compatible components: SSR-40DD, Relay (e.g., JQX-38F XXVDC).

Image: Application 3 wiring diagram, showing connections for larger heaters using external components.
4. Operation
On/Off Operation
To turn the controller on or off, keep the Lamp - I/O button depressed for 2 seconds.
Setting Temperature and Humidity Set-Point
When the temperature set-point (P3) or humidity set-point (P9) is configured, the temperature and humidity control parameters are automatically generated.
- Keep the Set button depressed for 2 seconds to enter the setting status.
- Press Enter to switch between temperature setting (SV window displays "***" + "tt") and humidity setting (SV window displays "***" + "HH").
- Press ▲ or ▼ to adjust the set-point value. Holding the key will fast-set.
- Keep Enter depressed for 2 seconds to exit and save settings. The settings will be saved, and control parameters will be generated.
Note: If no key operation occurs for 15 seconds, the setting status will exit without saving.
Default Settings:
- Temperature set-point (P3): 38°C (Range: 1~65°C)
- Humidity set-point (P9): 60%RH (Range: 10~80%RH)
Setting Function Control Parameters (F-)
These parameters allow for advanced control and will change automatically generated values. Proceed with caution.
- Press Set and ▲ simultaneously to enter the function control parameter setting status.
- Press Enter to select parameters (e.g., F1 to FE).
- Press ▲ or ▼ to set the value.
- Keep Enter depressed for 2 seconds to exit and save settings.
Note: If no key operation occurs for 15 seconds, the setting status will exit without saving.
Function Control Parameter (F-) Code Table:
| Code | Function | Range | Note | Factory Default |
|---|---|---|---|---|
| F1 | Egg turn period | 1~999 min | 90 | |
| F2 | Egg turn time | 0~999 sec | 0: no egg turning function | 180 |
| F3 | Egg turn times | 0~999 times | 0: turn for ever | 0 |
| F4 | Air exhausting period | 1~999 min | 120 | |
| F5 | Air exhausting time | 0~999 sec | 0: no air exhausting | 30 |
| F6 | Temperature calibration | -9.9~9.9°C | 0.0 | |
| F7 | Humidity calibration | -20~20% | 0 | |
| F8 | Illumination period | 1~999 min | 90 | |
| F9 | Illumination time | 0~999 min | 0: no illuminating function | 0 |
| FF | Incubated days | 0~99 day | Can reset only | 0 |
| Ft | Egg turn period time saving | 0/1 | 0: not saving. 1: saving | 0 |
| FM | Egg turned counter | 0~999 times | Can reset only | 0 |
| FE | Egg turned counter reset | 0/1 | 0: reset to zero when turn offline or power supply. 1: keeps | 0 |
Temperature Control Logic
- Main heater: On when room temperature ≤ P4 (Main temperature low limit). Off when room temperature ≥ P3 (Main temperature up limit).
- Aux. heater: On when room temperature ≤ P6 (Aux temperature low limit). Off when room temperature ≥ P5 (Aux temperature up limit).
- Fan: On when room temperature ≥ P1 (Exhaustion temperature up limit). Off when room temperature ≤ P2 (Exhaustion temperature low limit).
Humidity Control Logic
- Humidifier: On when room humidity ≤ Pb (Humidity low limit). Off when room humidity ≥ P9 (Humidity up limit).
- Fan (for dehumidifying, if PE=1): On when room humidity ≥ Pc (Exhaustion humidity up limit). Off when room humidity ≤ Pd (Exhaustion humidity low limit). If PE=0, no protecting exhaustion when over wet.
Egg Turn Control
- For every F1 (Egg turn period), the egg turn output will be on for F2 (Egg turn time).
- Egg turn left and right outputs alternate. One left turn + one right turn equals one egg-turn.
- The egg turned counter (FM) increases by 1 for each egg-turn. If FM reaches F3 (Egg turn times), egg turning stops, and UP/DOWN LEDs blink.
- To force left turning, keep ▲ depressed for 2 seconds.
- To force right turning, keep ▼ depressed for 2 seconds.
- Egg Tray Status: Turning direction changes every time power is supplied or turned online. If power is lost during turning, the direction is maintained after power is restored.
- Egg Turn Period Time Saving (Ft): If Ft=1, the egg-turn-period time is saved every 3 minutes and resumes after power supply returns. If Ft=0, the time is not saved.
- Egg Turned Counter Reset (FE): If FE=0, the counter resets to zero when power is supplied or turned online. If FE=1, the counter is not reset. You can manually reset it by setting FM to zero.
Illumination Operation
- Manual On/Off: Press Lamp - I/O to toggle the lamp.
- Timer On/Off: For every F8 (Illumination period), the lamp will be on for F9 (Illumination time).
Exhaustion Timer Control
For every F4 (Air exhausting period), the fan will be on for F5 (Air exhausting time).
5. Maintenance
Humidity Sensor Care
The humidity sensor's accuracy can be affected by dust, water, or dew. Keep it clean and dry. Before cleaning, ensure there is no static electricity in your hands.
6. Troubleshooting
Warning Codes
| Code | Indication |
|---|---|
| E1 | Temperature sensor failure |
| E2 | Humidity sensor failure |
| E3 | Room temperature is higher than P0 (High temperature warning point) |
| E4 | Room temperature is lower than P7 (Low temperature warning point) |
| E5 | Room humidity is higher than P8 (High humidity warning point) |
| E6 | Room humidity is lower than PP (Low humidity warning point) |
Alarm Control
When room temperature or humidity exceeds warning points (P0, P7, P8, PP), the buzzer will alarm, and the corresponding display will blink. Press Enter to stop and restore the buzzer alarming.
Temperature and Humidity Calibration
The sensors have a tolerance and can be calibrated to achieve absolute 0.1℃ and 1% RH accuracy.
- Temperature calibration: Set F6.
- Humidity calibration: Set F7.
Restore to Factory Settings
To restore the controller to factory default settings:
- Keep ▲ and ▼ depressed simultaneously for 2 seconds. The SV window will display "000" + "00".
- Press Lamp - I/O twice; the buzzer will beep.
- Release the keys, and the controller will restore to factory default settings.
7. User Tips
- This controller is highly regarded by users for its reliability and ease of use, making it a popular choice for various incubation needs.
- Many users have expressed satisfaction with its performance, noting it as a top-tier controller for their applications.
- The ability to use different input and multi-power outputs is a significant advantage, offering flexibility for diverse setups.
8. Warranty and Support
The manufacturer is responsible for the device itself. For detailed warranty information and support, please refer to the official LILYTECH documentation.
A comprehensive PDF manual for the ZL-7928A is available for download. You can access it by copying and pasting the following URL into your browser:
https://manuals.plus/m/0b5e986efcf4adbd784f223b47968ccaae8299ec7fbdfc559cf1080e29123685