1. Introduction
The MASTECH MS6818 is a professional portable wire and cable tracker designed for locating and testing various types of electrical lines and pipes. It consists of a transmitter and a receiver, offering multi-functional capabilities for both AC/DC voltage measurement and signal tracking. This manual provides detailed instructions for safe and effective use of the device.
2. Safety Information
IMPORTANT SAFETY WARNING:
This product is designed for short circuit measurement and is NOT intended for live circuit measurements. If an AC220V voltage measurement short circuit point is attempted, the transmitter may display garbled code. Always ensure that all power supplies are disconnected from the circuit before performing any short circuit measurements.
General Safety Precautions:
- WARNING: This instrument may cause dangerous current voltages. All connections must be protected against electrical shock.
- Remove test leads from circuits before opening the case or battery door.
- Do not operate the device with an open case.
- The device complies with IEC61010-1 300V CAT III, Pollution Degree 2 standards.
3. Package Contents
Upon opening your MASTECH MS6818 package, please verify that all the following items are included:
- MS6818 Transmitter
- MS6818 Receiver
- Test Leads (Red and Black)
- Alligator Clips (Red and Black)
- Grounding Rod
- User Manual
- Carrying Bag

4. Product Overview
The MS6818 system comprises two main units: a Transmitter and a Receiver. Each unit features an LCD display and intuitive controls for various functions.
4.1. Receiver (MS6818R)
The receiver is compact, strong, and durable, designed for precise signal detection.

- Detecting Head: For sensing signals.
- OFF/ON Button: Powers the unit on or off.
- LCD Display: Shows detection information, settings, and battery status.
- Upward/Downward Adjustment Sensitivity Buttons: Adjusts the receiver's sensitivity.
- UAc Button: For specific AC voltage detection functions.
- Backlight/Buzz Button: Toggles display backlight and buzzer sound.
- Flashlight On/Off Button: Activates the built-in flashlight for use in dark environments.
- MANUAL Button: For manual mode selection.
- Speaker: Emits audible signals.
4.2. Transmitter (MS6818T)
The transmitter is easy to use and features multiple functions for signal generation and voltage measurement.

- Flashlight: For illuminating work areas.
- Grounding Hole: Connection point for grounding.
- "+" Jack: Positive connection point.
- LCD Display: Shows transmitting power, codes, battery energy, and detected voltage.
- Power On/Off Button: Powers the unit on or off.
- Sound On/Off Button: Toggles the sound output.
- Signal Strength Setting: Adjusts the strength of the transmitted signal.
- Start/Stop Button: Initiates or halts signal transmission.
- Select Up/Down Buttons: Navigates through menu options or adjusts settings.
- Set/Confirm Code Signal: Sets or confirms the transmission code.

- 1. Transmitter battery voltage is low
- 2. Transmit power level (I, II or III)
- 3. Transmission code (default display code F)
- 4. AC voltage symbol
- 5. DC voltage symbol
- 6. Number of voltage
- 7. Delivery status
- 8. Code being transferred
- 9. Strength of the transmitted signal
- 10. A symbol indicating a voltage
- 11. Mute mode symbol
- 12. Temperature display
5. Setup
Before using your MS6818, ensure batteries are installed correctly and all components are connected as required for your specific application.
5.1. Battery Installation
The Transmitter requires one 9V battery (IEC 6LR61) and the Receiver requires six 1.5V AAA batteries (IEC LR03). Batteries are not included. Refer to the battery compartment on the back of each unit for correct polarity and installation.

5.2. Connecting Test Leads and Accessories
Connect the red and black test leads to the appropriate jacks on the transmitter. Attach the alligator clips or grounding rod as needed for your testing scenario.
6. Operating Instructions
The MS6818 is versatile for various cable and pipe locating tasks. Always ensure proper connections and safety precautions before operation.
6.1. General Operation
- Power On: Press the green power button on both the Transmitter and Receiver to turn them on.
- Adjusting Sensitivity: Use the "LEVEL" up/down buttons on the Receiver to adjust sensitivity for optimal detection.
- Setting Transmission Code (Transmitter): Use the "CODE SEL." buttons on the Transmitter to select a unique transmission code if using multiple transmitters or to avoid interference.
- Backlight/Flashlight: Use the dedicated buttons on both units to activate backlight for the display or the flashlight for illumination in dark areas.
- Mute Function: Press and hold the backlight/buzz button on the Receiver for 1 second to mute the buzzer.
6.2. Specific Applications
6.2.1. Locating Lines in Walls
Use the device to find broken wiring or short circuits within the walls of your home or building. Connect the transmitter to the line you wish to trace. Use the receiver to scan the wall surface and identify the signal path.

6.2.2. Finding Underground Cables and Pipes
The MS6818 can check for interruptions or short-circuits in underground cables and pipes. For optimal results, ensure the grounding rod is properly inserted into the earth.


6.2.3. Locating Fuses and Sockets
This tool is useful for tracking electrical installation lines, side branches of circuits, receptacles, and switch distribution boxes to locate fuses or sockets that may be hidden or need identification.

7. User Tips
- For accurate short circuit measurements, always ensure the circuit is completely de-energized. Measuring live AC220V short circuits can lead to incorrect readings or damage the device.
- When working in dimly lit areas, utilize the built-in backlight for the LCD display and the flashlight for better visibility.
- Adjust the receiver's sensitivity (LEVEL buttons) to optimize detection depth and accuracy based on the material and specific application. Higher sensitivity may be needed for deeper or weaker signals.
- If multiple signals are present or you are working with multiple transmitters, use the "CODE SEL." function on the transmitter to set a unique transmission code for clear differentiation.
- The transmitter's self-check function (displayed on its LCD) can help confirm its operational status before starting a task.
- For underground tracing, ensure the grounding rod is firmly placed in conductive soil to establish a good ground connection for the transmitter.
8. Maintenance
To ensure the longevity and accuracy of your MASTECH MS6818, follow these maintenance guidelines:
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the device in its carrying bag in a cool, dry place when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears on the LCD display to ensure optimal performance.
- Inspection: Regularly inspect test leads, alligator clips, and the grounding rod for any signs of wear or damage. Replace damaged accessories immediately.
9. Troubleshooting
If you encounter issues with your MS6818, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No display or device won't turn on. | Dead or incorrectly installed batteries. | Check battery polarity and replace with fresh batteries. |
| Garbled code on transmitter display. | Attempted measurement on a live AC220V short circuit point. | Immediately disconnect from the circuit. Ensure all power is off before measuring short circuits. |
| Weak or no signal detection. | Low transmitter power level, incorrect sensitivity setting, poor grounding, or signal interference. | Increase transmitter power level. Adjust receiver sensitivity. Ensure proper grounding. Check for other signal sources. |
| Inaccurate depth readings. | Material and specific application variations. | Depth of tracking depends on the material. Practice in known environments to understand limitations. |
10. Technical Specifications
10.1. Transmitter Specifications
| Parameter | Value |
|---|---|
| Output signal | 125 kHz |
| External voltage identification range | DC 12-400V ±2.5%; AC 12-400V (50-60Hz) ±2.5% |
| Display | LCD, with function display and column chart |
| External voltage's dielectric strength | Max. 400V AC/DC |
| Overvoltage type | CAT III 300V |
| Pollution degree | 2 |
| Power supply | 1x9V, IEC 6LR61 (Not included) |
| MIN current | About 31mA |
| MAX current | About 115mA |
| Fuse | F 0.5A 500V, 6.3x32mm |
| Range of temperature (In work) | 0°C to 40°C, with max relative humidity of 80% (non-condensation) |
| Range of temperature (In storage) | -20°C to 60°C, with max relative humidity of 80% (non-condensation) |
| Altitude | Max. 2000m |
| Dimensions (HxWxD) | 190mm x 89mm x 42.5mm |
| Weight (Without battery) | About 360g |
| Weight (With battery) | About 420g |
10.2. Receiver Specifications
| Parameter | Value |
|---|---|
| Depth of tracking | Depends on the material and specific applications |
| Single pole application | About 0-2m |
| Dual-pole application | About 0-0.5m |
| Single loop line | Up to 2.5m |
| Grid voltage identification | About 0-0.4m |
| Display | LCD, with function display and column chart |
| Power supply | 6x1.5V AAA, IEC LR03 (Not included) |
| MIN current | About 32 mA |
| MAX current | About 89 mA |
| Range of temperature (In work) | 0°C to 40°C, with max relative humidity of 80% (non-condensation) |
| Range of temperature (In storage) | -20°C to 60°C, with max relative humidity of 80% (non-condensation) |
| Altitude | Max. 2000m |
| Dimensions (HxWxD) | 241.5mm x 78mm x 38.5mm |
| Weight (Without battery) | About 280g |
| Weight (With battery) | About 350g |
11. Warranty and Support
For warranty information and technical support, please contact the seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.