1. Introduction

The Mastech MS5908A/MS5908C Circuit Analyzer is a specialized test instrument designed for rapid fault location in AC low-voltage distribution lines. This device offers simple operation and accurate measurements, enabling timely detection of line problems that could lead to electric shock, electrical fires, or abnormal equipment operation. It is an essential tool for electricians and maintenance professionals.

Note on Models:

  • MS5908A: Designed for 110V input voltage, typically with a US plug.
  • MS5908C: Designed for 220V input voltage, typically with an EU plug.

2. Safety Information

Always observe basic safety precautions when using this instrument to reduce the risk of fire, electric shock, and personal injury. Read and understand all instructions before use.

  • Ensure the device is suitable for the voltage of the circuit being tested (110V for MS5908A, 220V for MS5908C).
  • Do not use the device if it appears damaged or is operating abnormally.
  • Avoid contact with live circuits.
  • Always disconnect power before inspecting or replacing components if applicable.
  • Use appropriate personal protective equipment (PPE) such as insulated gloves and safety glasses.
  • Do not operate in wet conditions or explosive atmospheres.

3. Setup

3.1 Battery Installation

The MS5908A/MS5908C requires 6 AAA batteries (not included) for operation.

  1. Locate the battery compartment on the back of the device.
  2. Open the battery cover.
  3. Insert 6 AAA batteries, ensuring correct polarity (+ and -).
  4. Close the battery cover securely.
Back view of MS5908A Circuit Analyzer with battery compartment open, showing 6 AAA battery slots.
Figure 3.1: Battery compartment showing slots for 6 AAA batteries.

3.2 Initial Power On

Press the green power button to turn on the device. The LCD screen will illuminate, indicating the device is ready for use.

4. Operating Instructions

The Mastech Circuit Analyzer features an intuitive interface with a clear LCD display and dedicated function buttons.

Front view of MS5908C Circuit Analyzer showing LCD display and control buttons.
Figure 4.1: Front view of the MS5908C Circuit Analyzer.

4.1 Control Buttons

  • Power Button (Green): Turns the device ON/OFF.
  • FUNC: Cycles through different measurement functions.
  • HOLD: Freezes the current reading on the display.
  • Light Button (Sun icon): Toggles the display backlight.
  • TEST: Initiates RCD/GFCI tests.
  • Up/Down Arrows: Used for navigation or adjusting parameters in certain modes.

4.2 Measurement Functions

  1. TRMS AC Voltage Measurement: The device measures True RMS AC voltage. Plug the device into the socket to display the voltage.
  2. Wire Drop Measurement:
    • MS5908A: Measures wire drop with artificial loads of 12A, 15A, and 20A.
    • MS5908C: Measures wire drop with artificial loads of 5A, 8A, and 10A.
    • Select the wire drop function using the FUNC button and follow on-screen prompts.
  3. Phase Voltage, Neutral Wire, Voltage to Earth, Voltage, Frequency Measurement: These parameters are typically displayed automatically or can be cycled through using the FUNC button when the device is plugged into a live socket.
  4. Conductor Impedance Measurement: Measures the impedance of the phase (live) wire, neutral wire, and earth wire. Select this function via FUNC and follow the instructions.
  5. 3-Wire Socket Connection Mode Identification: The device can identify the connection mode of a 3-wire socket, indicating if the neutral is on the left, live on the right, and if an earth wire is present. This is usually displayed on the LCD with indicators like N, L, E.
  6. RCD (Residual Current Device) Testing:
    • Plug the device into an RCD-protected socket.
    • Select the RCD test function using FUNC.
    • Press the TEST button to initiate the RCD trip test. The device will measure the triggering time and current.
  7. GFCI (Ground Fault Circuit Interrupter) Testing:
    • Plug the device into a GFCI-protected socket.
    • Select the GFCI test function using FUNC.
    • Press the TEST button to initiate the GFCI trip test. The device will measure the triggering time and current.

4.3 Backlight and Data Hold

  • Backlight: Press the Light button (sun icon) to turn the LCD backlight on or off for improved visibility in low-light conditions.
  • Data Hold: Press the HOLD button to freeze the current measurement on the display. Press it again to release the hold.
Play video
Watch video online
Video 4.2: A brief demonstration of the Mastech Circuit Analyzer in use.

5. Maintenance

5.1 Battery Replacement

When the low battery indicator appears on the LCD, replace all 6 AAA batteries promptly to ensure accurate readings and proper device function. Refer to Section 3.1 for battery installation steps.

5.2 Cleaning

Clean the device regularly with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the device is turned off and unplugged before cleaning.

5.3 Storage

Store the circuit analyzer in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.

6. Troubleshooting

If you encounter issues with your Mastech Circuit Analyzer, try the following:

  • Device does not power on: Check if batteries are correctly installed and have sufficient charge. Replace if necessary.
  • Inaccurate readings: Ensure the device is properly connected to the circuit. Verify the correct model (MS5908A for 110V, MS5908C for 220V) is being used for the local voltage.
  • RCD/GFCI test fails to trip: Ensure the circuit is indeed protected by an RCD/GFCI. If it is, and the test still fails, there may be a fault in the RCD/GFCI itself, which should be inspected by a qualified electrician.
  • Display issues: If the display is dim, activate the backlight. If segments are missing, check battery levels.

For persistent issues, contact customer support.

7. Specifications

ParameterSpecification
Model NumbersMS5908A, MS5908C
Is Smart DeviceNo
Brand NameMastech
OriginMainland China
CertificationCE
Power Supply1.5V AAA x 6 (not included)
Size19.5cm x 7.5cm x 3.3cm (7.7in x 3in x 1.3in)
WeightApprox. 642g-655g
Wire Voltage Range85.0~265.0V (±(1.0%+0.2V))
Frequency Range45.0~65.0Hz (±(1.0%+0.2Hz))
Voltage Drop Range0.1%~99.9% (±(2.5%+0.2%))
Loaded Voltage Range10.0~265.0V (±(2.5%+0.2V))
Neutral Wire to Earth Voltage0.0~10.0V (±(2.5%+0.2V))
Conductor Impedance0.00~3.00Ω (±(2.5%+0.02Ω))
RCD Triggering Time1ms~6.500s (±(1.0%+2ms))
RCD Triggering Current30mA~37mA (±(1.0%+0.2mA))
GFCI Triggering Time1ms~6.500s (±(1.0%+2ms))
GFCI Triggering Current6mA~9mA (±(1.0%+0.2mA))
Side view of MS5908A Circuit Analyzer with dimensions labeled: 19.5cm/7.7inch height, 7.5cm/3inch width, 3.3cm/1.3inch thickness.
Figure 7.1: Device dimensions for MS5908A model.

8. User Tips

  • Always ensure the plug type of your device (US for MS5908A, EU for MS5908C) matches the socket you are testing.
  • For critical measurements, take multiple readings to ensure consistency.
  • Keep the LCD clean for optimal readability.
  • When testing RCDs/GFCIs, be prepared for the circuit to trip, which will cut power to the tested outlet.
  • If you are unsure about any electrical testing procedure, consult a qualified electrician.

9. Warranty and Support

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact the seller directly. For technical support or service inquiries, please reach out to the authorized Mastech service center or your point of purchase.

© 2023 Mastech. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.