1. Introduction
The TASI TA800A is a high-precision, portable digital multimeter designed for a wide range of electrical measurements. It features auto-ranging capabilities for AC/DC voltage, DC current, and resistance, making it suitable for various DIY electrical tasks. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your TA800A multimeter.
2. Safety Information
Always observe safety precautions when using electrical testing equipment. Failure to do so may result in injury or damage to the meter. This device is rated 600V CAT III.
- Do not exceed the maximum input values specified for each measurement range.
- Ensure test leads are in good condition and properly connected before making measurements.
- Do not use the meter if it appears damaged or if the case is open.
- Replace batteries and fuses only with the specified types and ratings.
- Avoid touching exposed wiring or circuit components while measuring.
- Always turn off power to the circuit before connecting or disconnecting test leads for current measurements.

3. Package Contents
Verify that all items are present in your package:
- 1 x TASI TA800A Digital Multimeter (Host)
- 1 x Instruction Manual
- 1 x Certificate
- 1 x Pair of Test Leads (Red and Black)

4. Product Overview
The TASI TA800A digital multimeter features a compact design with an easy-to-read LCD and a rotary knob for function selection.

4.1 Front Panel Components
- LCD Screen: Displays measurement readings, units, and function indicators.
- Data Hold/Backlight Button (H/>2s): Short press to hold the current reading; long press (2 seconds) to activate/deactivate the backlight.
- Rotary Knob Switch: Used to select the desired measurement function (OFF, AC Voltage, DC Voltage, Resistance, Continuity, Diode, DC Current).
- COM Input Jack: Common (negative) input for all measurements. Connect the black test lead here.
- VΩmA Input Jack: Positive input for Voltage, Resistance, Continuity, Diode, and milliampere (mA) current measurements. Connect the red test lead here.
- 10A Input Jack: Positive input for 10A DC current measurements. Connect the red test lead here for high current.
4.2 Rear Panel Components
- Battery Compartment: Houses the 2x 1.5V AAA batteries.
- Kickstand: Allows the meter to stand upright for easier viewing.
5. Initial Setup
5.1 Battery Installation
The TASI TA800A multimeter requires 2 x 1.5V AAA batteries (not included). To install or replace batteries:
- Ensure the multimeter is turned OFF.
- Locate the battery compartment cover on the rear of the device (refer to Figure 2.1).
- Use a screwdriver to open the battery compartment.
- Insert two 1.5V AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Replace the battery compartment cover and secure it with the screw.
Important: Always remove test leads from the meter before opening the battery compartment to prevent electrical shock.
6. Operating Instructions
Before making any measurements, ensure the test leads are securely plugged into the correct input jacks.
6.1 AC Voltage Measurement
- Turn the rotary knob to the "AC 600V" range.
- Connect the red test lead to the "VΩmA" input jack and the black test lead to the "COM" input jack.
- Carefully touch the red and black test leads to the neutral and live wires of the AC circuit, respectively.
- The AC voltage value will be displayed on the screen.

6.2 DC Voltage Measurement
- Turn the rotary knob to the "DC 20V" range (or appropriate DC voltage range).
- Connect the red test lead to the "VΩmA" input jack and the black test lead to the "COM" input jack.
- Touch the red test lead to the positive (+) terminal and the black test lead to the negative (-) terminal of the DC source (e.g., battery).
- The DC voltage value will be displayed on the screen.

6.3 Resistance Measurement
- Turn the rotary knob to the "200KΩ" range (or appropriate resistance range).
- Connect the red test lead to the "VΩmA" input jack and the black test lead to the "COM" input jack.
- Ensure the circuit or component under test is de-energized.
- Touch the red and black test leads to both ends of the resistance.
- The resistance value will be displayed on the screen.

6.4 DC Current Measurement
- Turn the rotary knob to the "10A" or "200mA/250V" DC current range.
- For measurements up to 200mA, connect the red test lead to the "VΩmA" input jack. For measurements up to 10A, connect the red test lead to the "10A" input jack. Connect the black test lead to the "COM" input jack.
- Important: To measure current, the multimeter must be connected in series with the circuit. Turn off power to the circuit, break the circuit, and insert the meter.
- Apply power to the circuit. The DC current value will be displayed.
- After measurement, turn off power, remove the meter, and restore the circuit.
6.5 Continuity Test
- Turn the rotary knob to the continuity/diode symbol (often shared with resistance).
- Connect the red test lead to the "VΩmA" input jack and the black test lead to the "COM" input jack.
- Ensure the circuit or component is de-energized.
- Touch the test leads to the ends of the component or wire. If there is continuity (low resistance), the meter will beep.
6.6 Diode Test
- Turn the rotary knob to the continuity/diode symbol.
- Connect the red test lead to the "VΩmA" input jack and the black test lead to the "COM" input jack.
- Ensure the diode is disconnected from any power source.
- Touch the red test lead to the anode and the black test lead to the cathode of the diode. A forward voltage drop will be displayed. Reverse the leads; an open circuit (OL) should be displayed.
6.7 Backlight and Data Hold
- Backlight: Long press the "H/>2s" button for approximately 2 seconds to turn the LCD backlight ON or OFF.
- Data Hold: Short press the "H/>2s" button to freeze the current reading on the display. Press again to release.
7. Maintenance
7.1 Cleaning
Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents.
7.2 Battery Replacement
When the battery indicator appears on the LCD, replace the batteries as described in the "Battery Installation" section (5.1). Always use 2 x 1.5V AAA batteries.
7.3 Fuse Replacement
If the current measurement function fails, the fuse may need replacement. Refer to the warning on the back of the meter (Figure 2.1) for fuse specifications:
- For mA range: F 200mA/250V
- For 10A range: F 10A/250V
To replace a fuse, open the meter case (this typically requires removing screws and should only be done by qualified personnel if unsure) and replace the blown fuse with one of the identical type and rating.
7.4 Automatic Power Off
The meter will automatically shut down after approximately 15 minutes of inactivity to conserve battery life. Press any button or turn the rotary knob to wake it up.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not turn on. | Dead or incorrectly installed batteries. | Check battery polarity; replace batteries. |
| No reading or "OL" displayed. | Open circuit, incorrect range, or blown fuse (for current). | Check circuit continuity, select appropriate range, check/replace fuse. |
| Inaccurate readings. | Low battery, poor test lead connection, or external interference. | Replace batteries, ensure secure connections, move away from strong electromagnetic fields. |
| Backlight not working. | Backlight turned off or low battery. | Long press H/>2s button; replace batteries. |
9. Specifications
| Parameter | Specification |
|---|---|
| Model | TA800A |
| Display Type | Digital Display (2000 Counts) |
| DC Voltage Range | 0.1mV ~ 600V (±(1.0% reading +5 words)) |
| AC Voltage Range | 0.1mV ~ 600V |
| DC Current Range | 0.01mA ~ 10A (±(1.0% reading +5 words)) |
| Measuring Resistance Range | 0.1Ω - 20MΩ |
| Is Smart Device | No |
| DIY Supplies | Electrical |
| Battery | 2 x 1.5V AAA (not included) |
| Automatic Shutdown | After 15 minutes of inactivity |
| Dimensions (approx.) | 125mm (4.9in) x 65mm (2.5in) |
10. User Tips
- Always ensure the correct function and range are selected before making a measurement to avoid damaging the meter or the circuit.
- For current measurements, remember to connect the meter in series with the load and use the appropriate input jack (mA or 10A).
- The backlight feature is useful in dimly lit environments; remember to turn it off to save battery.
- Keep spare AAA batteries on hand, as they are not included with the product.
11. Warranty and Support
For warranty information and technical support, please refer to the documentation provided by your retailer or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.