1. Introduction
The Mestek CM86B is a high-precision, auto-ranging True-RMS clamp meter designed for comprehensive electrical measurements. It offers a wide range of functions including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, temperature, diode, and continuity tests. Equipped with a large jaw and an optional iFlex flexible current clamp, it can measure currents up to 1000A (3000A with iFlex). Its intelligent anti-burn design and HD backlight ensure safe and convenient operation in various environments.
This manual provides detailed instructions for the safe and effective use of your Mestek CM86B clamp meter. Please read it thoroughly before operation.
2. Safety Information
WARNING: To avoid electric shock or personal injury, please read and understand all safety information before using this product.
- Always adhere to local and national safety codes.
- Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired.
- Do not use the meter if it appears damaged or if the test leads are damaged.
- Verify the meter's operation by measuring a known voltage or current before use.
- Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and earth ground.
- Use caution with voltages above 30V AC RMS, 42V peak, or 60V DC. Such voltages pose a shock hazard.
- Keep your fingers behind the finger guards on the test probes during use.
- Do not operate the meter around explosive gas, vapor, or dust.
- Before measuring current, ensure the circuit is de-energized and the clamp jaw is fully closed around the conductor.
- The meter is rated for CAT III 1000V and CAT IV 600V.
3. Package Contents
Upon opening the package, please verify that all items listed below are present and undamaged:
- Mestek CM86B Digital Clamp Meter
- Cloth bag
- Packing box
- Thermocouple (temperature probe)
- Test leads (red and black)
- User Manual
- iFlex flexible current clamp (if selected with the appropriate model option)
Video: Unboxing the Mestek CM86B Clamp Meter and its accessories.

Image: Visual representation of the Mestek CM86B clamp meter and its included accessories.
4. Product Overview
The Mestek CM86B is an advanced clamp meter featuring a large 42mm jaw for easy clamping around conductors. It includes a clear HD backlight display for visibility in various lighting conditions.
4.1 Key Features
- True-RMS Measurement: Provides accurate readings for non-sinusoidal waveforms.
- Auto-Ranging: Automatically selects the correct measurement range.
- Large Jaw Design: 42mm jaw opening for conductors up to 42mm in diameter.
- HD Backlight: Ensures clear display readability day or night.
- iFlex Flexible Clamp (Optional): Extends AC current measurement range up to 3000A.
- Automatic Voltage Low Impedance (Auto-V LoZ): For ghost voltage detection.
- Inrush Current Measurement: Captures motor startup current.
- Non-Contact Voltage (NCV) Detection: For safe voltage presence checks.
- Live Wire Identification: Distinguishes live from neutral/ground wires.
- Data Hold: Freezes the current reading on the display.
- DC Current Zeroing: Resets DC current readings for accuracy.
- Temperature Measurement: With included thermocouple.
- Flashlight Function: Illuminates the work area.

Image: Overview of the CM86B clamp meter and its iFlex accessory, showing key measurement capabilities.

Image: Comprehensive list of functions available on the clamp meter.
4.2 Appearance Introduction

Image: Labeled diagram of the clamp meter's external features and controls.
5. Setup
5.1 Battery Installation
The Mestek CM86B requires 3x1.5V AAA batteries for operation. To install or replace batteries:
- Ensure the meter is turned OFF.
- Locate the battery compartment on the back of the meter.
- Use a screwdriver to open the battery cover.
- Insert three AAA batteries, observing the correct polarity (+/-).
- Close the battery cover and secure it with the screw.
5.2 Connecting Test Leads
For voltage, resistance, capacitance, diode, continuity, and temperature measurements:
- Insert the red test lead into the 'INPUT' terminal.
- Insert the black test lead into the 'COM' terminal.
5.3 Connecting iFlex Flexible Clamp (Optional)
If using the iFlex flexible current clamp for extended AC current measurements:
- Ensure the meter is turned OFF.
- Plug the iFlex connector into the designated port on the clamp meter.
- The iFlex clamp can extend the AC current range up to 3000A.
6. Operating Instructions
Rotate the function selection knob to the desired measurement mode. Use the 'SEL' button to cycle through sub-functions within a mode (e.g., AC/DC, Celsius/Fahrenheit).
6.1 AC/DC Current Measurement
- Rotate the knob to the AC/DC current mode.
- For DC current, if the reading is below 0.4A, the signal input on the screen may flicker. Readings ≥0.5A will be stable.
- Open the clamp jaw and enclose a single conductor. Ensure the jaw is fully closed.
- Read the current value on the display.

Image: Example of DC current measurement.
6.1.1 DC Current Zeroing
The ZERO clearing function is only used for DC current measurements. Since DC current can be affected by magnetic fields, it is recommended to long-press the 'ZERO' button to reset the reading before measurement for improved accuracy.

Image: Illustration of the DC current zeroing function.
6.1.2 Inrush Current Measurement
To measure the maximum current at the moment a machine starts (inrush current):
- Set the gear to AC or DC current mode.
- Short press the 'INRUSH' button to enter inrush measurement mode.
- Initiate the machine's startup sequence. The meter will capture and display the peak inrush current.

Image: Example of measuring inrush current during motor startup.
6.2 AC/DC Voltage Measurement
- Rotate the knob to the AC/DC voltage mode.
- Connect the test leads to the circuit points to be measured.
- Read the voltage value on the display.

Image: Example of AC voltage measurement.
6.2.1 Variable Frequency Drive (VFD) Measurement
In the AC voltage gear, short press the 'VFD' key to enter the variable frequency measurement function. This is useful for measuring voltage in circuits controlled by variable frequency drives.
6.3 Resistance Measurement
- Rotate the knob to the resistance mode (Ω).
- Ensure the circuit is de-energized.
- Connect the test leads across the component to be measured.
- Read the resistance value.
6.4 Capacitance Measurement
- Rotate the knob to the capacitance mode (mF).
- Ensure the capacitor is discharged before measurement.
- Connect the test leads across the capacitor terminals.
- Read the capacitance value.
6.5 Diode Test
- Rotate the knob to the diode mode.
- Connect the red test lead to the anode and the black test lead to the cathode of the diode.
- The display will show the forward voltage drop. Reverse the leads to check for open circuit.
6.6 Continuity Test
- Rotate the knob to the continuity mode.
- Ensure the circuit is de-energized.
- Connect the test leads across the circuit or component.
- If continuity exists (low resistance), the buzzer will sound.
6.7 Temperature Measurement
- Rotate the knob to the temperature gear (°C/°F).
- Plug the thermocouple into the 'INPUT' and 'COM' terminals.
- Place the thermocouple tip on or in contact with the object whose temperature is to be measured.
- Press the 'SEL' button to switch between Celsius and Fahrenheit.

Image: Example of contact temperature measurement.
6.8 Non-Contact Voltage (NCV) Detection
- Rotate the knob to the NCV mode.
- Bring the NCV induction probe (top of the clamp meter) close to the circuit or conductor under test.
- Different alarm prompts (beeps and LED indicators) will be issued according to the voltage intensity detected, indicating the presence of AC voltage without direct contact.

Image: NCV non-contact measurement in action.
6.9 Live Firewire Recognition
- Rotate the knob to the 'Live' mode.
- Insert the red test lead into the neutral wire port of an outlet or circuit.
- If it detects a live wire, the buzzer will sound an alarm and the display will indicate 'Live'.
- If it is a neutral wire or ground wire, there will be no response or a different indication.

Image: Live Firewire Recognition in a circuit panel.
6.10 Data Hold
Press the 'HOLD' button to freeze the current reading on the display. The 'H' symbol will appear. The hold symbol will flash every 3 seconds. Press the 'HOLD' button again to cancel data retention and return to live measurement.

Image: Data retention function showing 'H' symbol.
6.11 Flashlight and Backlight
The meter includes a flashlight function to illuminate the work area and an HD backlight for the display. These can be activated via dedicated buttons or combined with other functions as indicated on the device.

Image: HD Backlight display for clear readings.

Image: Visual examples of various detailed measurement functions.
7. Specifications
The following table outlines the technical parameters for the Mestek CM86B clamp meter:

Image: Detailed technical specifications for the CM86B model.
| Parameter | Value (CM86B) |
|---|---|
| Auto range | Yes |
| Highest input voltage of COM/INPUT terminal | AC 750V / DC 1000V |
| DC voltage | 0~1000V |
| AC voltage | 0~750V |
| Resistance | 0~60MΩ |
| Capacitance | 0~60mF |
| AC current | 0~1000A |
| DC current | 0~1000A |
| Temperature measure | -20~1000°C / -4~1832°F |
| Frequency range | 40~400Hz |
| iFlex current (optional) | 3000A |
| Inrush current | 1000A |
| Backlight | Yes |
| Maximum display value | 5999 counts |
| Over range display | OL or -OL |
| Sampling time | About 3 times / second |
| Power supply | 3x1.5V AAA batteries |
| VFD/NCV/Live/Diode | Yes |
| On-off test / buzzer | Yes |
| Data hold | Yes |
| Data zero | Yes |
| Size | 250*85*45mm |
| Jaw size | 42mm |
| iFlex flexible clamp length | 1.8m |
| iFlex Flexible Clamp Dimensions | 7.5mm |
| Weight | About 368g (without battery) |
8. Maintenance
8.1 Cleaning
Wipe the meter case with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the terminals free of dirt and moisture.
8.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Refer to section 5.1 for battery installation instructions.
8.3 Storage
If the meter is not used for a long period, remove the batteries to prevent leakage and damage. Store the meter in a dry, cool environment, away from direct sunlight and extreme temperatures.
9. Troubleshooting
- Display shows 'OL' or '-OL': This indicates an over-range condition. The measured value exceeds the maximum range of the selected function. Select a higher range if available, or ensure the measurement is within the meter's capabilities.
- Display flickers during DC current measurement: For DC current measurements below 0.4A, the signal input on the screen may flicker. This is normal behavior. Readings of 0.5A or higher will typically be stable.
- No response during Live Wire Recognition: If the meter does not respond when testing a wire in 'Live' mode, it likely indicates that the wire is neutral or ground, not a live wire.
- Meter does not turn on or display is dim: Check the batteries. Replace them if they are low or depleted. Ensure they are installed with correct polarity.
10. User Tips
- Zeroing DC Current: Always remember to long-press the 'ZERO' button before taking DC current measurements to compensate for any residual magnetic fields and ensure the most accurate reading.
- VFD for AC Voltage: The VFD function is specifically for measuring AC voltage in circuits controlled by variable frequency drives, not for AC current.
- Safety First: Double-check your connections and selected mode before making any measurements, especially when dealing with high voltages or currents.
11. Warranty and Support