The HLTNC series motor driver is a high-precision control device designed for stepper motors and closed-loop servo motors. It converts DC power into precise drive signals to control motor speed, torque, and position, featuring adjustable current output, micro-stepping functionality, and multiple protection mechanisms (overcurrent, overvoltage, overheating, short circuit). The stepper driver supports bipolar stepper motors with smooth micro-stepping up to 1/128, ensuring low-noise operation for general-precision applications. The closed-loop servo driver integrates encoder feedback processing, enabling real-time position correction and high-dynamic response for precision motion control. Compatible with most CNC systems (Grbl, Mach3, FANUC) and PLCs, the driver is widely used in CNC machining, robotic arms, 3D printing, and other automation scenarios.
Ensure no short circuits between wires (use a multimeter to check for continuity).
Figure 5: DM865C Driver to Stepper Motor Wiring Example
Terminal Number
Symbol
Description
Voltage Range
1
A+
A phase motor winding+
2
A-
A phase motor winding -
3
B+
B phase motor winding+
4
B-
B phase motor winding-
5
VCC
Input DC Voltage is positive
18-80VDC
6
GND
Input current voltage negative
4.3.3 Control Signal Wiring
Connect the CNC system/PLC control signals to the driver's control interface:
Pulse Signal (PUL+): Connect to control system's pulse output positive terminal.
Pulse Signal (PUL-): Connect to control system's pulse output negative terminal.
Direction Signal (DIR+): Connect to control system's direction output positive terminal.
Direction Signal (DIR-): Connect to control system's direction output negative terminal.
Enable Signal (ENA+/-): Connect to control system's enable output (optional, for motor on/off control).
Use shielded cables for control signals (keep away from power cables) to avoid electromagnetic interference.
Terminal
Symbol
Description
Illustration
1
DIR+
Direction positive input
Signal source +5V~24V universal, no need to connect resistors in series
2
DIR-
Direction negative input
3
PUL+
Pulse positive input
4
PUL-
Pulse Negative input
5
ENA+
Motor enable positive input
When the signal is valid, the motor is in a free state and the motor is not locked
6
ENA-
Motor enable negative input
7
ALM+
Alarm signal negative input
8
ALM-
Alarm signal positive input
Figure 6: Common Anode and Common Cathode Connection Diagrams
4.3.4 Encoder Wiring (Closed-Loop Servo Driver)
Connect the motor's encoder cable to the driver's encoder interface:
Encoder VCC (5V): Connect to driver's encoder power positive terminal.
Encoder GND: Connect to driver's encoder power negative terminal.
Encoder A: Connect to driver's encoder signal A terminal.
Encoder B: Connect to driver's encoder signal B terminal.
Encoder Z (Zero Pulse): Connect to driver's encoder signal Z terminal (optional).
Secure the encoder cable with cable ties to prevent damage.
5. Configuration Settings
5.1 Stepper Driver Configuration
Set the micro-stepping resolution via DIP switches (e.g., 1/16 for smooth motion, 1/2 for high speed).
Adjust the current limit potentiometer to match the motor's rated current (use a multimeter to measure).
Enable/disable the enable signal function (if required by the control system).
5.2 Closed-Loop Servo Driver Configuration
Set the motor type and encoder resolution via DIP switches (match the motor's specifications).
Adjust the position gain (KP) and speed gain (KI) potentiometers for optimal dynamic response.
Set the overcurrent and overheating protection thresholds (default settings recommended for initial use).
5.3 Button Function Description
Button
Function Description
M
Function selection: P parameter, JOG, RESET, L parameter switching
▲
When the value is changed: +1, long press to increase rapidly. In jog mode: long press the motor to rotate forward
▼
When the value is changed: -1, long press to decrease quickly. In jog mode: long press the motor to reverse
◀
Press and hold this key for 0.5 seconds. Enter parameter setting
When setting parameters, press once to shift to the left once
After the setting is completed, press and hold this key for 0.5 seconds to confirm that the setting is successful and return to the current function code
When there is a fault, long press this key for 2 seconds to reset the fault
Power On Sequence: Turn on the power supply → Wait for the driver to initialize (PWR LED steady) → Send control signals from the CNC system/PLC.
Speed Control: Adjust the pulse frequency from the control system (higher frequency = higher motor speed; do not exceed the driver's maximum output frequency).
Direction Control: Toggle the DIR signal to change the motor's rotation direction (set via DIP switch for active high/low).
Motor Enable/Disable: Activate the ENA signal to enable the motor (output current applied); deactivate to disable (motor free to rotate).
Power Off Sequence: Stop sending control signals → Disable the motor (if ENA is used) → Turn off the power supply.
6.2 Closed-Loop Servo Driver Exclusive Operations
Position Correction: If the motor deviates from the target position, the driver automatically adjusts via encoder feedback (no manual reset required).
Alarm Handling: If the ALM LED is on, refer to Section 8 (Troubleshooting) to identify the fault (e.g., encoder error, overcurrent).
Gain Adjustment: For unstable motion (oscillation), reduce the position gain (KP); for slow response, increase KP slightly.
6.3 Operating Guidelines
Avoid sudden changes in pulse frequency (use acceleration/deceleration settings in the control system) to prevent motor overcurrent.
Do not exceed the driver's maximum output current or input voltage (risk of driver damage).
For continuous operation (24 hours), monitor the driver's temperature and reduce current if overheating occurs.
Do not disconnect the motor or encoder cables while the driver is powered on (risk of short circuit or component damage).
7. Maintenance and Care
7.1 Daily Maintenance
Clean the driver's surface and heat sink daily with a soft brush or compressed air (remove dust to ensure heat dissipation).
Check the wiring connections for loosening (vibration may cause gradual disconnection).
Inspect the status LEDs during operation (ensure no abnormal alarm activation).
7.2 Regular Maintenance (Every 3 Months)
Tighten all terminal screws (power, motor, control signals) with a screwdriver (avoid over-tightening).
Clean the encoder interface (closed-loop driver) with a dry cloth (remove dust or debris).
Test the protection functions (overcurrent, overheating) by simulating fault conditions (professional personnel only).
Check the power supply voltage stability (fluctuations ≤±10% of rated input voltage).
7.3 Long-Term Storage (≥1 Month)
Disconnect all wiring connections and clean the driver thoroughly.
Store the driver in a dry, well-ventilated environment (humidity ≤60%, temperature 0°C ~ +30°C).
Avoid storing near high-temperature sources, magnetic fields, or corrosive substances.
Re-test the driver before reuse (check for proper initialization and output).
8. Important Safety Notes
Ensure the driver is properly grounded to prevent electric shock and electromagnetic interference.
Wear protective gloves and goggles during installation/wiring (risk of electric shock from power supply).
Do not touch the driver's heat sink or terminals during operation (may be hot).
Do not disassemble the driver without authorization—this will void the warranty and damage internal components (e.g., power modules, microcontrollers).
Disconnect the power supply before wiring, maintenance, or replacing the driver.
Keep the driver away from water, oil, dust, and high-temperature environments (exceeding 60°C).
Use only compatible motors and power supplies (refer to Section 2 for technical parameters).
9. Troubleshooting
Fault Phenomenon
Possible Causes
Troubleshooting Methods
Driver PWR LED Not Lit
Power supply disconnected;
Input voltage out of range;
Power terminal loose
Check power connection;
Verify input voltage (12-48V DC for stepper, 24-72V DC for servo);
Tighten power terminals
Motor Fails to Rotate
Wrong motor wiring;
Control signals not received;
Motor disabled (ENA signal);
Overcurrent protection triggered
Recheck motor phase wiring;
Test control signals with a multimeter;
Activate ENA signal;
Reduce current limit
Alarm LED (ALM) On (Closed-Loop)
Encoder wiring error;
Encoder damaged;
Position deviation excessive;
Overheating
Recheck encoder connections;
Replace encoder;
Adjust gain or reduce load;
Improve ventilation
Motor Jitter/Vibration
Micro-stepping setting too low;
Control signal interference;
Current limit too low
Increase micro-stepping (e.g., 1/16);
Use shielded control cables;
Adjust current limit to match motor rated current
Driver Overheating
Current limit too high;
Poor ventilation;
Continuous high-load operation
Reduce current limit (within motor rated current);
Add heat dissipation fan;
Reduce load or operating time
Incorrect Rotation Direction
DIR signal wiring error;
DIP switch setting (active high/low);
Motor phase wires reversed
Recheck DIR signal connection;
Toggle the DIR polarity DIP switch;
Swap motor A+ and A- (or B+ and B-) wires
10. Packaging List
Figure 9: DM865C Driver Packaging
Stepper/Servo Motor Driver ×1
Power Connection Cable (1.5m) ×1
Motor Connection Cable (1.5m) ×1
Encoder Cable (1.5m, Closed-Loop Only) ×1
DIP Switch Configuration Guide ×1
Mounting Bolts (M4) ×4
User Manual (This Document) ×1
11. Warranty and Support
Warranty Period: 12 months warranty against manufacturing defects (non-human damage).
Warranty Exclusions: Damage caused by improper wiring, overvoltage/overcurrent, disassembly, misuse, or natural disasters.
Technical Support: For wiring, configuration, or performance issues, contact our technical team with the driver model, motor specifications, and fault description.
Replacement Parts: Original replacement parts (cables, fuses, terminal blocks) are available for purchase.
Version: V1.0
Applicable Models: HLTNC Stepper Motor Driver Series / HLTNC Closed-Loop Servo Driver Series
Date: [Leave Blank for Customization]
For further assistance, please refer to the official PDF user manual: User Manual (PDF)
12. User Tips
Optimal Performance: For best results, ensure your power supply voltage is on the higher end of the recommended range (e.g., 48V-80V DC) to achieve higher motor speeds and faster response times.
Heat Management: Always ensure adequate ventilation around the driver. For continuous high-current operation, consider adding an external heat dissipation fan to prevent overheating and prolong the driver's lifespan.
Wiring Best Practices: Use shielded cables for control signals to minimize electromagnetic interference, especially in noisy industrial environments. Double-check all connections before powering on to avoid damage.
Digital Display Advantage: Utilize the integrated digital display for quick and accurate parameter adjustments and real-time status monitoring. This eliminates guesswork and simplifies troubleshooting.
Motor Matching: Ensure the motor's rated current is properly matched with the driver's current limit settings to prevent motor or driver damage and achieve smooth operation.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.