VEVOR A2-8015, A2-8022, A2-8030, A2-8040, A2-8055, A2-8075

Rate this product
Contents

VEVOR VFD Frequency Inverter User Manual

Models: A2-8015, A2-8022, A2-8030, A2-8040, A2-8055, A2-8075

Variable Speed Drive Frequency Converter for CNC Milling Machines and other applications

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR VFD Frequency Inverter. The VFD converter is designed for controlling the speed of AC motors, suitable for both constant torque loads (e.g., air compressors, HVAC units) and variable torque loads (e.g., pumps, fans). It functions as a motor speed controller and a phase converter, accepting 1 or 3 phase input and providing 3 phase output. The unit utilizes Sine Wave PWM (SPWM) control technology for high performance.

VEVOR VFD Frequency Inverter unit
VEVOR VFD Frequency Inverter unit

2. Important Safety Instructions

WARNING: High voltage inside. To prevent electric shock or injury:

  • Do not connect to AC power until all wiring is complete and verified.
  • Wait at least 5 minutes after disconnecting power before inspecting or touching internal components. Ensure the charge lamp is turned off before proceeding.
  • Only qualified personnel should perform installation, wiring, and maintenance.
  • Ensure proper grounding of the unit.
  • Do not operate the VFD with damaged wiring or casing.
  • Keep the unit away from water, dust, and corrosive environments unless specifically rated for such conditions.
Caution label on VFD unit
Caution label on the VFD unit indicating high voltage and safety precautions.

3. Product Overview

3.1 Key Features

  • Premium Quality: Constructed with an ABS flame-retardant material case for high impact resistance and long service life. Utilizes US Intel and Silicon Lab's chips for reliable performance.
  • Powerful Performance: Employs a unique control method to achieve high torque, high precision, and a wide speed regulating range. Features powerful anti-jamming capabilities, low output ripple torque, and stable low-speed operation.
  • Efficient Cooling: Equipped with fan cooling and a built-in radiator for effective heat dissipation, maintaining optimal internal temperature. An independent air duct design isolates electrical components from contaminants, allowing use in harsh environments.
  • Smart Digital Display: User-friendly keyboard design with clear buttons for quick and easy operation. The large digital display provides intuitive and clear readings. The detachable panel allows for convenient remote control.
  • Multiple Protection: Incorporates various safeguards for stable and reliable operation, including overload protection, fuse protection, over-voltage (DC voltage > 400V) or under-voltage (DC voltage < 200V) protection, restart protection, stall protection, short-circuit protection, and over-heat protection.
  • Wide Application: Suitable for machinery winding machines, mixers, extruders, slitters, winders, compressors, ventilators, pumps, grinders, elevators (not for passenger elevators), centrifuges, and other speed control machines.
VFD applications
The VFD is suitable for a wide range of industrial applications including crushers, blenders, forging machines, and compressors.

3.2 Control Panel Layout

The VFD features a user-friendly control panel for easy operation. Refer to the diagram below for button identification and function.

VFD Control Panel Diagram
Detailed view of the VFD control panel with labeled buttons.
  • RUN Key: Initiates operation.
  • STOP/RESET Button: Stops operation or resets errors.
  • SET Key: Enters parameter setting mode.
  • REV/FWD: Toggles between reverse and forward direction.
  • JOG (Forward): Forward Jog / Menu Input Key to Right.
  • JOG (Reverse): Reverse Jog / Menu Input Key to Left.
  • Up Arrow: Increase value / Navigate up.
  • Down Arrow: Decrease value / Navigate down.

4. Specifications

The VEVOR VFD Frequency Inverter is available in several power ratings. The following table outlines the key specifications for each model:

VFD Product Specifications Table
Comprehensive specifications for VEVOR VFD models from 1.5KW to 7.5KW.
VEVOR VFD Frequency Inverter Specifications
Parameter1.5KW VFD2.2KW VFD3.0KW VFD4.0KW VFD5.5KW VFD7.5KW VFD
ModelA2-8015A2-8022A2-8030A2-8040A2-8055A2-8075
Power1.5 kW2.2 kW3.0 kW4.0 kW5.5 kW7.5 kW
Input VoltageAC 200-260V
Output VoltageAC 220V
Input Current7.5A10A20A18A25A35A
Output Current10A15A20A26.7A36A50A
Input Phase1 or 3 Phase
Output Phase3 Phase
Input Frequency45-65 Hz
Output Frequency0.1-400 Hz
Horsepower2 HP3 HP4 HP5 HP7.5 HP10 HP
Working Temperature14~104℉ / -10 ~ 40 ℃
Humidity10-95% Relative Humidity (without dew)
Vibration0.4 G
Net Weight (approx.)0.88 kg (1.94 lbs)0.95 kg (2.1 lbs)1.58 kg (3.48 lbs)2.22 kg (4.9 lbs)2.52 kg (5.56 lbs)2.62 kg (5.78 lbs)
Product Size (approx.)114 x 82 x 140 mm (4.5 x 3.2 x 5.5 in)125 x 163 x 170 mm (4.9 x 6.4 x 6.7 in)150 x 180 x 220 mm (5.9 x 7.1 x 8.7 in)

5. Installation and Wiring

Proper wiring is crucial for the safe and correct operation of the VFD. Ensure all power is disconnected before attempting any wiring.

5.1 Three-Phase Wiring Diagram

Three-phase wiring diagram for VFD
Wiring diagram for three-phase input to the VFD.
Three-Phase Wiring Port Descriptions
Port NameDescription
R, S, TThree-phase 220V power connect R, S, T. For single-phase 220V input, connect R and T.
U, V, WThree-phase AC output ports. Can only connect to pure resistance or inductance loads such as motors or electric heaters.
FWD/STOPForward/Stop control input.
REV/STOPReverse/Stop control input.
RESETReset input.
D0+ / D0-Multi speed D0.
D1 / D2Digital frequency up / Multi speed D1.
D2 / JOGMulti speed D2 / External point moving enable.
GNDCommon control signal ground.
5V_IN, 10V_IN, 0-20mA_INExternal analog signal input (0-5V, 0-10V, 0-20mA).
5V_OUT5V output for external potentiometer power.
12V_OUT12V output.
Relay OutputNormally closed and normally open relay contacts.

5.2 Single-Phase Wiring Diagram

Single-phase wiring diagram for VFD
Wiring diagram for single-phase input to the VFD.
Single-Phase Wiring Port Descriptions
Port NameDescription
L, NSingle-phase power input.
U, V, WThree-phase AC output ports. Can only connect to pure resistance or inductance loads such as motors or electric heaters.
FWD/STOPForward/Stop control input.
REV/STOPReverse/Stop control input.
RESETReset input.
D0+ / D0-Multi speed D0.
D1 / D2Digital frequency up / Multi speed D1.
D2 / JOGMulti speed D2 / External point moving enable.
GNDCommon control signal ground.
5V_IN, 10V_IN, 0-20mA_INExternal analog signal input (0-5V, 0-10V, 0-20mA).
5V_OUT5V output for external potentiometer power.
12V_OUT12V output.
Relay OutputNormally closed and normally open relay contacts.

6. Operation

The VFD's operation is managed through its intuitive digital display and control panel buttons.

  1. Power On: After ensuring correct wiring and safety, apply power to the VFD. The digital display will illuminate.
  2. Parameter Setting: Press the 'SET' key to enter the parameter setting mode. Use the Up/Down arrow keys to navigate through parameters and adjust values. Refer to the detailed parameter list in the full product manual for specific settings (e.g., motor parameters, acceleration/deceleration times, control modes).
  3. Start Operation: Press the 'RUN' key to start the motor. The VFD will accelerate the motor to the set frequency.
  4. Stop Operation: Press the 'STOP/RESET' button to stop the motor.
  5. Direction Change: Use the 'REV/FWD' button to toggle the motor's rotation direction.
  6. Jog Function: Use the 'JOG' buttons for momentary forward or reverse operation, typically used for testing or precise positioning.
  7. Frequency Adjustment: Adjust the output frequency (and thus motor speed) using the Up/Down arrow keys while in run mode, or through analog input if configured.
VFD with digital display
The smart digital display provides intuitive and clear feedback during operation.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your VFD.

  • Cleaning: Periodically clean the exterior of the VFD with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure ventilation openings are free from dust and debris.
  • Fan Inspection: Check the cooling fan regularly for proper operation and cleanliness. The fan is designed for high air volume and is easy to replace or clean.
  • Heat Dissipation: Ensure adequate clearance around the VFD for proper airflow and heat dissipation. The built-in radiator and independent air duct are crucial for maintaining operating temperature.
  • Wiring Check: Periodically inspect all wiring connections for tightness and signs of wear or damage.
  • Environmental Conditions: Ensure the VFD operates within the specified working temperature and humidity ranges to prevent damage.
VFD cooling system
The VFD features an independent cooling air duct and built-in radiator for effective heat management.

8. Troubleshooting

This section provides guidance on common issues you might encounter with your VFD. For complex problems, consult a qualified technician.

ProblemPossible CauseSolution
Motor does not startNo power, incorrect wiring, emergency stop active, parameter error.Check power supply, verify wiring, release emergency stop, check motor parameters.
VFD displays 'OV' (Over-Voltage)Input voltage too high, regenerative braking issue.Check input voltage, increase deceleration time, consider adding a braking resistor.
VFD displays 'UV' (Under-Voltage)Input voltage too low, power supply fluctuation.Check input voltage, ensure stable power supply.
VFD displays 'OC' (Over-Current)Motor overload, short circuit in output, acceleration time too short.Reduce motor load, check motor and output wiring for shorts, increase acceleration time.
VFD displays 'OH' (Over-Heat)Ambient temperature too high, cooling fan blocked or faulty, VFD overloaded.Ensure proper ventilation, clean fan/radiator, reduce load or operating time.
Motor runs erratically or vibratesIncorrect motor parameters, loose connections, motor fault.Verify motor parameters (e.g., frequency, voltage), check all wiring, inspect motor.
VFD multiple protection features
The VFD includes multiple safeguards such as over-heat, fuse, and over/under-voltage protection.

9. User Tips

  • Matching Load: Always ensure the VFD's power rating (KW/HP) is appropriately matched to the motor and the expected load. For heavy loads, consider a VFD with a slightly higher power rating than the motor to handle peak demands effectively.
  • Parameter Backup: After configuring your VFD settings, it is advisable to record or back up the parameters. This can save time during troubleshooting or if settings are accidentally reset.
  • Remote Control: Take advantage of the detachable panel for remote control in situations where direct access to the VFD is inconvenient or unsafe.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact VEVOR customer service or refer to the official VEVOR website. Keep your purchase receipt and product model information handy when contacting support.

© 2023 VEVOR. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.