GEYA W2R ATS 2P

Contents

GEYA W2R Automatic Transfer Switch User Manual

Model: W2R ATS 2P (Available in 4P 63A and 4P 100A variants for AC110V/AC220V)

1. Product Overview

The GEYA W2R series Mini ATS Dual Power Automatic Transfer Switch is a PC Level device designed for micro household power transfer. It ensures continuous, reliable, and safe power supply by automatically switching to backup power when the normal city power is abnormal, with no interruption. This specific model is designed for PV System Power Transfer to City Power (SPECIAL USE).

Key Features:

  • Millisecond Switching
  • Quick Switch
  • PV Level Compatibility
  • Wide Range of Application
  • Compact Design
GEYA W2R Automatic Transfer Switch front view
Figure 1: Front view of the GEYA W2R Automatic Transfer Switch.
GEYA W2R ATS features and applications
Figure 2: Features and typical applications including bank offices, ports, machinery production, and household electricity.
Play video
Watch video online
Video 1: GEYA Company Introduction and Product Overview.

2. Specifications

AttributeValue
Brand NameGEYA
Model NumberW2R ATS 2P
TypeMini Circuit breaker
FunctionPV POWER TO CITY POWER
Rated VoltageAC220V OR 110V
Rated Current In63A / 100A
Rated Frequency50/60Hz
Insulation VoltageAC 690V
Rated Impulse Withstand Voltage8KV
Working Condition Voltage85% Us ~ 110% Us
Switching Time<50ms
Action Time<50ms
Electrical Life2000 times
Mechanical Life5000 times
MountingDin Rail
Ambient Temperature Range-5°C to +40°C (24-hour average must not exceed +35°C)
AltitudeNot exceeding 2000 meters
Operating HumidityUp to 50% at +40°C; up to 90% at +25°C (condensation prevention required)
Contamination LevelLevel 3
CertificationCE

Product Dimensions

Product dimensions in millimeters, showing front and side views with safety distances.
Figure 3: Product dimensions (mm) for 2P, 3P, and 4P models, including safety clearances (S1 ≥ 30mm, S2 ≥ 208mm).
Detailed technical parameters and product size for W2R ATS
Figure 4: Detailed technical parameters and product size for W2R ATS, showing various configurations.

3. Safety Information

Please read this manual carefully before installing or operating the product. If you have any questions, please contact our company. Unauthorized disassembly of the product is strictly prohibited to prevent instrument failure or malfunctions.

  • Installation and wiring must be performed by qualified personnel familiar with this manual.
  • Before installation, check the ATS for any damage or missing parts.
  • Manually operate the mechanism using the operation handle to verify smooth movement, correct switching of all phases, and the load status of both power sources.
  • Ensure the text on the ATS panel is visible from the front. Contact the manufacturer if the correct mounting orientation cannot be achieved due to wiring or space constraints.
  • Install suitable circuit breakers in accordance with IEC 60947-6-1 and the distribution system design to ensure personnel and equipment safety.
  • This product has undergone insulation testing before leaving the factory. Incorrect dielectric testing will damage the control system, and it is strictly prohibited to conduct dielectric testing with ATS.

Safe Operating Limits

Do not operate the device at control voltages below:

  • 190 V (for models with Ue: AC 220 V, 50/60 Hz)
  • 95 V (for models with Ue: AC 110 V, 50/60 Hz)

Operation below these limits may cause overheating and permanent damage.

4. Installation

DIN Rail Installation

  1. Insert the upper end of the ATS base into the DIN rail.
  2. Push the lower end of the ATS base into the DIN rail until the snap fastener locks securely.

DIN Rail Disassembly

  1. Insert a screwdriver into the round hole of the DIN rail snap fastener at the bottom of the ATS.
  2. Use a screwdriver to pry the DIN rail snap fastener downward.
  3. Tilt the ATS upwards and remove it from the DIN rail.

Screw Mounting

  1. Pull out the upper and lower snap fasteners located at the bottom of the ATS.
  2. Secure the ATS to the panel with screws.

5. Wiring Instructions

The GEYA W2R ATS is designed for automatic transfer between a PV (Solar) system and city power. Ensure all connections are secure and follow local electrical codes.

Wiring Diagram for 4P GEYA W2R ATS
Figure 5: Wiring Diagram for a 4P GEYA W2R ATS, showing connections for Common Power Supply (Main Power A) and Backup Power (Source B).
  • Connect the phase (AR) and neutral (AN) to the main power input terminals (mandatory).
  • Connect the phase (BR) and neutral (BN) to the backup power input terminals (mandatory).
  • The power indication signal uses a dry contact output; the generator signal is taken from the common (C) and normally closed (NC) terminals.
  • Use copper wires with a cross-sectional area of at least 2.0 mm², and keep control circuit wiring as short as possible.
  • Connect the load to the lower terminals on the backup power side using stepped wiring.
  • Remove the isolation board before wiring, connect the load, reinstall the board, and ensure proper alignment. It is recommended to connect the load before wiring the backup power.

Product Components for Wiring Reference

  1. Composite Terminal Block for Main Power A
  2. Main Power Indicator
  3. Standby Power Indicator
  4. Manual / Automatic Selector Switch
  5. Composite Terminal Block for Standby Power B
  6. Main Power Terminals
  7. Standby Power Terminals
  8. Manual Rotary Switch
  9. Load Terminals
  10. Mounting Hole (4P)
Product overview with numbered components for wiring
Figure 6: Numbered components of the ATS for easy identification during wiring.

6. Operating Instructions

Manual / Automatic Operation

  • Automatic Operation: Electric (automatic) operation ensures reliable switching. Keep the selector switch in 'AUTO' mode during normal operation.
  • Manual Operation: Manual operation may cause contact wear and unstable performance due to variations in operator speed. Switch to manual mode ('MANU') only after power is disconnected and maintenance is completed. Return to automatic mode promptly after any manual operation.

Uninterruptible Power Supply Function

Diagram showing automatic transfer between Solar Power and City Power
Figure 7: Diagram illustrating the automatic transfer function between Solar Power (PV & Inverter AC output) and City Power (Grid).

The ATS automatically transfers between the PV system (Source A) and City Power (Source B) with a transfer time of less than 50ms, ensuring an uninterruptible power supply.

7. Maintenance and Storage

Maintenance and Inspection

  • Maintenance and inspection must be performed by qualified personnel after disconnecting all power supplies.
  • The first inspection should be completed within 6 months of commissioning, and at least once per year thereafter. In harsh environments, increase inspection frequency as needed.
  • Key tasks include removing dust and debris, checking contact parts for damage, discoloration, or burn marks, and measuring contact resistance if necessary.

Storage

  • If the ATS is damp or idle for an extended period, dry it thoroughly and measure insulation resistance with a 500V megohmmeter (minimum 10 MΩ).
  • Store the ATS in a clean, dry environment, protected from mechanical impact.

8. Troubleshooting

If the device is not functioning as expected, first verify all wiring connections are correct and secure according to the diagrams in Section 5. Check that the power sources are within the specified voltage ranges (85%-110% of rated voltage) and that the current is not less than 5A. If issues persist, please contact GEYA customer support for assistance.

9. User Tips

  • Voltage Stability: The rated voltage of the common and backup power supply must be in the range of 85%-110%, and the current cannot be less than 5A. Otherwise, the coil may overheat or even spontaneously burn. If your city voltage is not stable, consider adding voltage protectors to the system.
  • Phase Sequence: Ensure the input power supply is connected in the correct phase sequence for optimal performance and safety.

10. Warranty and Support

For warranty information, technical support, or any product-related inquiries, please refer to the official GEYA website or contact your authorized dealer. A detailed user manual in PDF format is available for download from the manufacturer's website for further reference.

© 2024 GEYA. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.