1. Introduction
The MASTECH MS6514 is a high-precision dual-channel digital thermometer designed for industrial applications. It utilizes a microprocessor-controlled system to provide accurate temperature measurements across a wide range, supporting various thermocouple types including K, J, T, E, R, S, and N. This manual provides essential information for the safe and effective operation, setup, and maintenance of your MS6514 thermometer.
Key features include:
- Compatibility with K, J, T, E, R, S, N thermocouples.
- Temperature display in Celsius (°C), Fahrenheit (°F), and Kelvin (K).
- Measurement of maximum, minimum, and average values.
- Data hold function.
- Ambient temperature deviation compensation.
- Relative time display.
- User-configurable automatic power-off.
- Self-calibration capability.
- Automatic and manual data saving.
- USB port for PC connectivity.
- Dual-channel input (T1, T2) for simultaneous measurements.
- Powered by a 9V battery.
2. Safety Information
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in injury or damage to the instrument.
- Always use the correct type of thermocouple for the intended measurement range.
- Do not expose the thermometer or probes to extreme temperatures or corrosive environments beyond their specified limits.
- Ensure the battery compartment is securely closed during operation.
- Do not attempt to open or modify the device, as this will void the warranty and may cause damage.
- Keep the device away from water and other liquids.
- Disconnect probes from high-voltage sources before handling.
3. Package Contents
Verify that all items are present and undamaged upon unpacking:
- 1x MASTECH MS6514 Main Unit
- 1x English User Manual (refer to the included physical copy or digital version)
- 1x Software CD
- 1x Storage Box
- 1x USB Data Cable
- 1x 30mm K-type Thermocouple Probe
- 1x 50mm K-type Thermocouple Probe
- 1x 100mm K-type Thermocouple Probe
- 1x 200mm K-type Thermocouple Probe
- 4x K-type Thermocouple Plugs


4. Product Overview
The MASTECH MS6514 features a robust design with a clear digital display and intuitive button layout for easy operation. The device supports dual-channel input, allowing for simultaneous temperature monitoring from two different locations.

Front Panel Controls:
- POWER Button: Turns the device on/off.
- T1/T2/T1-T2 Button: Toggles between displaying temperature from Channel 1, Channel 2, or the difference between Channel 1 and Channel 2.
- °C/°F/K Button: Changes the temperature unit between Celsius, Fahrenheit, and Kelvin.
- MAX/AVG/MIN Button: Cycles through maximum, average, and minimum recorded temperatures.
- HOLD Button: Freezes the current display reading.
- ENTER Button: Confirms selections in setup menus.
- SETUP Button: Accesses the device's settings menu.
- MEM Button: Accesses saved data.
- PC-Link Button: Activates PC communication mode.
- READ Button: Used for reading data or confirming actions.
5. Specifications
| Parameter | Value |
|---|---|
| Brand Name | MASTECH |
| Model Number | MS6514 |
| Theory | Temperature Sensor |
| Display Type | DIGITAL |
| Power Type | 9V Battery (AAA Battery type mentioned in properties, but 9V battery in description, assuming 9V for the device) |
| Max Measuring Temperature | 120°C & Above |
| Style | Handheld |
| Use | Industrial |
| Cable Length (Probes) | 2m |
| Display Size | 1.9 Inches & Under |
| Measure Type | K |
| Origin | Mainland China |
| Battery Included | No |
| Is Smart Device | No |
| High-concerned chemical | None |
| Certification | None |
Measurement Ranges by Thermocouple Type:
- K-type: -200.0°C to +1372°C / -328.0°F to +2501°F
- J-type: -210.0°C to +1200°C / -346.0°F to +2192°F
- T-type: -250.0°C to +400°C / -418.0°F to +752°F
- E-type: -150.0°C to +1000°C / -238.0°F to +1832°F
- R-type: 0°C to +1767°C / 32°F to +3212°F
- S-type: 0°C to +1767°C / 32°F to +3212°F
- N-type: -200.0°C to +1300°C / -328.0°F to +2372°F
Display Resolution: 0.1°C / 0.1°F / 0.1K
Accuracy:
- K, J, T, E: ±(0.2% + 0.5°C)
- R, S: ±(0.2% + 1°C)
- N: ±(0.2% + 0.5°C)
Temperature Scale: ITS-90
Applicable Standards: NIST-175
K-type Thermocouple Probes (Included):
- Lengths: 30mm, 50mm, 100mm, 200mm
- Diameter: 5mm
- Cable Length: 2 meters
- Temperature Range: 0-400°C


6. Setup
6.1 Battery Installation
- Locate the battery compartment cover on the back of the MS6514 unit.
- Slide or unscrew the cover to open it.
- Insert a fresh 9V battery, observing the correct polarity (+/-).
- Replace the battery compartment cover and ensure it is securely fastened.
6.2 Connecting Thermocouple Probes
- Identify the thermocouple type you are using (e.g., K-type).
- Connect the thermocouple probe to the corresponding input jack on the top of the MS6514 unit. The device has two input channels, T1 and T2.
- Ensure the thermocouple plug is fully inserted and securely connected.
- If using K-type probes, ensure the yellow K-type thermocouple plugs are correctly attached to the probe wires before connecting to the main unit.
7. Operating Instructions
7.1 Power On/Off
Press the POWER button to turn the thermometer on. Press and hold the POWER button again to turn it off.
7.2 Selecting Thermocouple Type
The MS6514 automatically detects the connected thermocouple type. If manual selection is required, refer to the 'SETUP' menu for thermocouple type configuration.
7.3 Changing Temperature Units
Press the °C/°F/K button to cycle through Celsius (°C), Fahrenheit (°F), and Kelvin (K) display units.
7.4 Single and Dual Channel Measurement
Press the T1/T2/T1-T2 button to switch between:
- T1: Displays temperature from Channel 1.
- T2: Displays temperature from Channel 2.
- T1-T2: Displays the temperature difference between Channel 1 and Channel 2.
7.5 MAX/MIN/AVG Measurement
Press the MAX/AVG/MIN button to view the maximum, average, or minimum temperature recorded since the device was powered on or the function was reset. Press repeatedly to cycle through these values.
7.6 Data Hold
Press the HOLD button to freeze the current temperature reading on the display. Press it again to release the hold and resume live readings.
7.7 Automatic Power-Off
The device features an automatic power-off function to conserve battery life. The default time can be adjusted in the 'SETUP' menu. To disable or adjust, navigate to the 'SETUP' menu and modify the auto-off settings.
7.8 Self-Calibration
The MS6514 supports user self-calibration. For detailed instructions on performing self-calibration, please refer to the dedicated 'User Self-calibration' section in the comprehensive manual provided on the software CD. Incorrect calibration can lead to inaccurate readings.
7.9 Data Saving and PC-Link
The thermometer can automatically or manually save measurement data. To access saved data, press the MEM button. To connect the device to a PC for data transfer and analysis, install the provided software from the CD and then press the PC-Link button on the thermometer to activate communication mode. Follow the software instructions for data management.
8. Maintenance
8.1 Cleaning
Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is completely dry before storage or next use.
8.2 Battery Replacement
When the low battery indicator appears on the display, replace the 9V battery as described in the 'Battery Installation' section (6.1). Always dispose of used batteries responsibly.
8.3 Storage
Store the thermometer and probes in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery to prevent leakage.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Dead or incorrectly installed battery | Replace battery or check polarity |
| Inaccurate readings | Incorrect thermocouple type selected; probe damaged; needs calibration | Verify thermocouple type; inspect/replace probe; perform self-calibration |
| "OL" or "--- " displayed | Temperature out of range; open circuit in probe; probe not connected | Ensure temperature is within range; check probe connection; replace faulty probe |
| PC-Link not working | Software not installed; USB cable faulty; PC-Link mode not activated | Install software; try another USB cable; press PC-Link button on device |
10. User Tips
- For critical measurements, allow the thermometer and probe to stabilize in the environment for a few minutes before taking a reading.
- When using dual channels, consider placing probes in similar environments initially to verify consistent readings before deploying them for differential measurements.
- Regularly check the battery level, especially before important measurement tasks, to avoid interruptions.
- Keep the software CD in a safe place, as it contains essential drivers and the full digital manual for advanced features like self-calibration and data logging.
- When connecting to a PC, ensure the thermometer is in PC-Link mode and the software is running to establish a connection.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.