Models: IR01C, IR01D, IR02C, IR03A, IR03B, T400, T600

1. Introduction and Overview

The MESTEK Non-Contact Digital Infrared Thermometer is a versatile tool designed for safe and accurate temperature measurement of various surfaces without physical contact. Equipped with a high-precision sensor and a colorful HD display, it offers quick response times and a range of features for industrial and general use. This manual provides essential information for the safe and effective operation of your device.

MESTEK IR01D Infrared Thermometer with laser points and display showing temperature and humidity.
MESTEK IR01D Infrared Thermometer displaying temperature and humidity.
Video demonstrating the MESTEK Infrared Thermometer's features and operation.

2. Safety Information

  • LASER RADIATION: Do not stare directly into the laser beam. Avoid direct eye exposure.
  • This product is NOT suitable for measuring body surface temperature, forehead temperature, or baby temperature. It is designed for industrial use.
  • Do not attempt to measure electric soldering irons or hair dryers, as this may lead to inaccurate readings or damage the device.
  • Keep the device away from children.

3. Product Features

  • Non-Contact Measurement: Safely measure temperatures from a distance.
  • High Precision Sensor: Ensures accurate readings with a quick response time of less than 0.5 seconds.
  • Colorful HD Screen: Clear and easy-to-read display.
  • Object Distance Ratio (D:S): 12:1 for accurate positioning.
  • Adjustable Emissivity: Range from 0.1 to 1.0 to suit different materials.
  • High and Low Temperature Alarm: Alerts when measured temperature exceeds set limits.
  • Unit Switch: Easily switch between Celsius (°C) and Fahrenheit (°F).
  • Data Retention: Holds the last measured value.
  • Automatic Sleep: Enters sleep mode after 15 seconds of inactivity to save energy.
  • Ambient Temperature & Humidity: Available on IR01C, IR01D, and IR02C models.
  • Temperature Probe: Available on IR02C model only.
  • Laser Indicator: 1-point for IR03A/IR03B, 13-points for IR01 and IR02 series.
Infrared thermometer display showing various features like HD color screen, 12:1 object distance ratio, unit switch, data retention, automatic sleep, and low battery prompt.
Key features displayed on the thermometer screen.
Close-up of the infrared thermometer highlighting the high precision sensor and quick temperature measurement of 0.1 seconds.
High precision sensor for rapid measurements.

4. Setup Instructions

  1. Install Batteries: Open the battery compartment and insert 2 AAA batteries (not included), ensuring correct polarity.
  2. Turn On: Pull the trigger to turn on the thermometer. The display will light up.
Two images showing quick measurement steps: 1. Install 2 AAA batteries. 2. Pull the trigger to turn on the thermometer.
Battery installation and device power-on.

5. Operating Instructions

Basic Measurement

  1. Point the thermometer at the target object.
  2. Press and hold the trigger to start measuring. The laser pointer will activate (if enabled) to assist with aiming.
  3. Release the trigger to hold the measurement data on the screen.

Laser Positioning

Press the MODE button to turn on the laser positioning. If you do not need positioning, you can ignore this step.

Infrared thermometer aiming a laser point at a surface, demonstrating non-contact measurement and safety.
Laser point aiming for precise measurement.

Parameter Settings (High/Low Alarm, Emissivity, Unit Switch)

Long press the middle MODE button to enter the setting mode. Press the MODE button repeatedly to cycle through the settings:

  1. Highest Temperature Setting: The highest temperature value will flash. Use the Up/Down buttons to adjust.
  2. Lowest Temperature Setting: The lowest temperature value will flash. Use the Up/Down buttons to adjust.
  3. Emissivity Setting: The emissivity value (e=0.95 by default) will flash. Use the Up/Down buttons to adjust between 0.1 and 1.0.
  4. °C/°F Switching Mode: The °C/°F indicator will flash. Use the Up/Down buttons to switch between Celsius and Fahrenheit.

Long press the middle MODE button again or short press the trigger to exit the setting mode.

Four diagrams showing how to set parameters: 1. Long press MODE for high temp alarm. 2. Press MODE again for low temp alarm. 3. Press MODE again for emissivity. 4. Press MODE again for C/F switch.
Steps for adjusting thermometer parameters.

MAX (Maximum) Measurement

When the thermometer is turned on, the default measurement value displayed is the maximum value. Continuous measurement can lock the higher temperature point.

Thermometer display showing 'MAX 23.6' indicating maximum temperature measurement.
MAX temperature measurement feature.

High and Low Temperature Alarm

When the measured temperature exceeds the set alarm value, the indicator light on the top of the thermometer will light up a red alarm light.

Infrared thermometer displaying a high temperature alarm with a red indicator light.
Visual alert for high temperature alarm.

6. Emissivity Adjustment

Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivities. For accurate measurements, adjust the emissivity setting on your thermometer to match the material being measured. The default setting is 0.95.

Table showing emissivity values for various materials like aluminum, concrete, iron, copper, plastic, and more.
Emissivity comparison table for common materials.

7. Measurement Tips

  • Object Distance Ratio (D:S): The thermometer has a D:S ratio of 12:1. This means that at a distance of 12 units, the measurement target diameter is 1 unit. For example, at 12 inches distance, it measures a 1-inch spot.
  • Boiling Liquids: When measuring boiling liquids, do not let smoke or steam touch the temperature sensing area. Keep the measuring angle at about 45°~60° to avoid interference.
  • Surface Temperature: The thermometer measures surface temperature. For internal temperatures, a probe thermometer is required (IR02C model only).
Diagram illustrating the 12:1 object distance ratio (D:S) for accurate temperature measurement.
Understanding the Object Distance Ratio (D:S).
Comparison showing incorrect and correct measurement methods for boiling liquids, emphasizing the 45-60 degree angle.
Correct measurement method for liquids.

8. Specifications

FeatureSpecification
Brand NameZLLJMETER (MESTEK)
Display TypeDIGITAL
Max Measuring Temperature120°C & Above
StyleHandheld
Power Type2x AAA Battery (not included)
Display Size2.0 - 3.9 Inches
UseIndustrial
Emissivity0.1~1.0 adjustable
Accuracy±2°C
Object Distance Ratio12:1
Response Spectrum8~14 µm
Response Timeless than 0.5s
Automatic Shutdown30 seconds
Storage Temperature-10~60°C
CertificationCE, FCC, RoHS
OriginMainland China

Model Specifics:

  • IR03A: -50~400°C, 1 point red indicator light.
  • IR03B: -50~600°C, 1 point red indicator light.
  • IR01A: -50~380°C.
  • IR01B: -50~550°C.
  • IR01C: -50~550°C, Ambient temperature: -10~60°C, Humidity: 0%~100%RH, 13 points red indicator light.
  • IR01D: -50~800°C, Ambient temperature: -10~60°C, Humidity: 0%~100%RH, 13 points red indicator light.
  • IR02C: -50~800°C, Temperature probe measurement, Ambient temperature: -10~60°C, Humidity: 0%~100%RH, Dew point mildew, 13 points red indicator light.
  • T400: -50~400°C.
  • T600: -50~600°C.

9. Troubleshooting

  • No Power: Ensure batteries are correctly installed and not depleted. Replace with fresh AAA batteries if necessary.
  • Inaccurate Readings:
    • Check the emissivity setting and adjust it according to the material being measured.
    • Ensure the target is within the optimal measurement distance (12:1 D:S ratio).
    • Avoid measuring through steam, smoke, or highly reflective surfaces.
  • Laser Not Working: Check if the laser positioning is enabled by pressing the MODE button.
  • Display Issues: If the display is dim or flickering, replace the batteries.

10. User Tips

  • For consistent and accurate results, always ensure the emissivity setting matches the material you are measuring.
  • Take multiple readings from the same spot to confirm accuracy, especially for critical measurements.
  • Keep the lens clean to prevent dust or debris from affecting readings.
  • Remember that this device measures surface temperature, which may differ from internal temperature.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.