FNIRSI SG-004A Multi-functional Signal Generator User Manual

Model: SG-004A | Brand: FNIRSI

FNIRSI SG-004A Multi-functional Signal Generator with test leads

The FNIRSI SG-004A is a versatile signal generator capable of outputting and measuring various electrical signals for industrial and laboratory applications.

1. Introduction

This manual provides detailed instructions for the FNIRSI SG-004A Multi-functional Signal Generator. Please read it carefully to ensure optimal use and understanding of the product's features and functions. The SG-004A is designed for a wide range of applications, including PLC system debugging, DCS system debugging simulation, valve positioner adjustment, instrumentation calibration, and inverter detection.

Video: Unboxing and demonstration of the FNIRSI SG-004A signal generator's features and dimensions.

2. Safety Instructions

  • Read this manual carefully to ensure proper operation and to obtain the best performance from the product.
  • Do not use the instrument in flammable or explosive environments.
  • Used batteries and discarded instruments must be disposed of in accordance with relevant national or local laws and regulations, not with household waste.
  • If you encounter any quality problems or have questions about using the instrument, contact FNIRSI customer service or the manufacturer for assistance.
  • WARNING: The safety limit voltage of the input terminal cannot exceed 30Vpp. Exceeding this limit will damage the equipment.

3. Product Overview

3.1. Key Features and Applications

The FNIRSI SG-004A is a multi-functional signal generator capable of handling various signal types for debugging, simulation, and calibration tasks.

FNIRSI SG-004A displaying various signal types

Image: The SG-004A supports DC Voltage, Current, Analog Source, Thermocouple Signal, RTD Signal, 24V Power Distribution Output, and Program Output.

Applications of FNIRSI SG-004A in industrial settings

Image: Applications include PLC System Debugging, DCS System Debugging Simulation, Valve Positioner Adjustment, Instrumentation Calibration, and Inverter Detection.

3.2. Interface Terminals

The device features 4 inner diameter 4mm wiring ports on the top surface, color-coded for easy identification:

  • Red (OUT): Output port, forms a pair with the black (COM) port.
  • Black (COM): Common ground for input and output.
  • Yellow (IN+): Positive input port.
  • Blue (IN-): Negative input port, can also function as an independent 24V test power supply. When used as an independent 24V supply, there is a 24V voltage between the (COM) port and the (IN-) port.
Labeled diagram of FNIRSI SG-004A buttons and interfaces

Image: Detailed view of the SG-004A's buttons and interface ports, including Input, Output, Function, Auto, On/Off, Curve, Preset, Convert, and the 2.4-inch TFT Full Color LCD Screen.

3.3. Power & Charging

  • Battery: Built-in 3000mAh large capacity lithium battery.
  • Battery Display: Current battery percentage is shown in the upper right corner of the display.
  • Charging Interface: Type-C port (DC 5V-12V).
  • Charging Status: When charging (up to 10W), the power button displays a red light. Once fully charged, it automatically stops charging and displays a blue light.

4. Button Panel Introduction

All buttons are made of white translucent silicone material with color LED backlighting to indicate function and mode. The keys are divided into a 3-Key area and a 5-Key area. The functions of the keys, especially the FN key and the 5-Key area keys, change based on the FN key state and the interface mode. The device defaults to the upshift function upon startup.

4.1. FN Key States

  • Default White Light: Normal operation.
  • Red Light: Activates the downshift function for other keys, allowing access to different modes or settings.

4.2. 5-Key Area Status (Backlight Colors)

  • White Light: Manual setting mode.
  • Green Light: Preset output mode.
  • Blue Light: Programming mode.
  • No Button Light: Conversion mode.

4.3. Button Function Operation

  1. RUN (White Light): Indicates power on/output is active.
  2. IN (Input Key):
    • In main interface: Switches input signal mode.
    • When FN is red: Enters input settings.
  3. OUT (Output Key):
    • In main interface: Switches output signal mode.
    • When FN is red: Enters output settings.
  4. FN (Exit/Return Key):
    • In main interface: Turns red to activate downshift functions for other keys (different modes).
    • In setting interface: Functions as a return button.
  5. PRESET (Up Function Key):
    • When white: Adds value or selects upward.
    • In history curve interface: Quick right shift by 100.
    • When FN is red (button is green): Enters/exits preset output mode, allowing quick recall of preset signal values using up/down/left/right buttons.
  6. AUTO (Left Function Key):
    • When white: Selects to the left.
    • In history curve interface: Moves cursor left point by point.
    • When FN is red: Enters/exits programming mode (button blue light). Functions change to single output (up), reset (down), end output (left), pause/continue (right).
  7. ON/OFF (Confirmation Button):
    • In main interface: Turns output on/off.
    • When FN is red: Turns recording on/off.
    • In setting interface: Confirms selection ("OK").
  8. CURVE (Right Function Key):
    • When white: Selects to the right.
    • In history curve interface: Moves cursor right point by point.
    • When FN is red: Switches between curve interface and character interface.
  9. CONVERT (Down Function Key):
    • When white: Decrements value or selects downward.
    • In history curve interface: Moves left quickly by 100.
    • When FN is red: Enters/exits conversion mode.

5. Display & Signal Description

5.1. Switching Signal Types

  • From the main interface, press the FN button until it turns red. Then, press the IN button to enter input settings or the OUT key to enter output settings. Navigate left/right to select the desired signal type. Press FN again to exit.
  • Various signal modes are available, each with different configurable parameters.

5.2. mA Current Signal

  • Mode Switch: In the main interface (FN white), press IN/OUT to switch between actual value and engineering quantity display.
  • Output Open Circuit Detection: If the output is on and the interface flashes "open circuit", it means the output signal is not connected or is near zero.
  • Output Circuit Voltage: The SG-004A can set current output no-load voltage. 12V is used to save power, while some devices require 24V drive capability.
  • Output Range: The limit range for current output can be set.

5.3. V Voltage Signal

  • Mode Switch: In the main interface (FN white), press IN/OUT to switch between actual value and engineering quantity display.
  • Overcurrent Protection: If the output voltage is shorted, the output will automatically shut down.
  • Output Range: The limit range for voltage output can be set.

5.4. XMT Passive Current Signal

  • Mode Switch: In the main interface (FN white), press IN/OUT to switch between actual value and engineering quantity display.
  • Output Range: The limit range for passive current output can be set.

5.5. Hz Pulse Signal

  • Modes: Frequency, PWM duty cycle, speed frequency, pulse quantitative/counting.
  • Input Mode Switch: In the main interface (FN white), press IN to switch modes directly.
  • Output Mode Switch: Long press OUT to switch modes.
  • Frequency Range: Select from 0~99.999Hz, 0~999.99Hz, 0~9999Hz, 0~200kHz.
  • Method: Select level/open circuit based on pull-up presence.
  • Output Peak Value: Max 24V.
  • Input Counting Method: Rising edge (OV to peak) or falling edge (peak to OV) increments counter by 1. "Jump" increments on any level change. Long press IN to clear count.
  • Frequency Mode Operation: Input frequency range 0~9999Hz (auto decimal shift). Output frequency range switched by pressing OUT (FN white).
  • PWM Mode Operation: Displays frequency (period) and duty cycle. Max frequency 9999Hz. Parameters can be set during output. Yellow cursor indicates selection when FN is white and OUT is pressed.
  • Speed Mode Operation:
    • Calculates motor/gear speed (1 revolution = 1 pulse).
    • Time Unit: RPS (per second), RPM (per minute), RPH (per hour). Max frequency 9999Hz.
    • Number Of Revolution Pulses: Selectable in speed setting.
    • Tooth Missing: Simulates engine speed.
  • Quantitative/Counting Mode Operation: Simulates flow control sensors (quantitative) or flow counts (counting). Input frequency value displayed. For output, cycle displayed in milliseconds. When FN is white, press OUT to switch between cycle and quantitative values. Cursor disappears after output, backlight turns blue, buttons change function (up: single pulse, down: program stop/reset, left: no function, right: start/pause).

5.6. mV Millivolt Signal

  • Modes: 110mV, Thermocouple, WR Thermocouple. Switch by pressing IN/OUT when FN is white.
  • Thermocouple Types: TC-S, B, E, K, R, J, T, N.
  • WR Thermocouple Types: WRE25, WRE26.
  • Temperature Unit: Celsius or Fahrenheit.
  • Cold Junction Setting: Meter-detected or user-defined temperature.
  • Cold End Temperature: Customized value.

5.7. 24V Loop Detection

Select the "24V" label in the OUT signal type interface to enter this function. The main interface will display the output 24V loop current. This supports unlimited input signal detection types.

  1. Loop 1: Outputs 24V between (OUT) and (COM) ports, detects loop current, and displays it in the "output 24V loop" area. Useful for testing pneumatic control valves or two-wire transmitters.
  2. Loop 2: Activates independent 24V power supply. The (IN-) port outputs 24V between (24V) and (COM) ports, without affecting input signal detection. Select mA for input. (IN-) and (IN+) can form a 24V output while detecting current loop.
  3. Independent 24V Supply: (IN-) port can be switched to independent 24V power supply, outputting a single DC24V voltage (the 24V port). Used with (IN+) to test two-wire transmitters.

Note:

  • 24V loop detection measures feedback current from the output signal port.
  • Independent 24V port and output port can form a 24V power supply, or combine with input (+) for a transmitter to supply power and measure feedback current.

5.8. Ohm Resistance Signal

  • Temperature Unit: Celsius or Fahrenheit.
  • Resistance Types: Pt100, Cu50, and RES. Switch by pressing IN/OUT when FN is white.
  • Resistance Offset: Corrects input/output resistance values.

6. Extensions

6.1. Engineering Quantity Conversion

For analog signals in industrial applications, it's often necessary to convert them to engineering quantity values. The instrument allows setting upper and lower limits for both engineering quantity and corresponding signal values in the input and output settings.

6.2. Preset Value

  • Parameter Setting: Configure signal values for the up, down, left, and right buttons.
  • Operation: When FN is red, press the PRESET key to start/exit preset mode. Once active, the up/down/left/right keys' backlights turn green, and their functions change to output the set values.

6.3. Signal Conversion

Converts an input signal into an output signal. For example, an input frequency signal (0-1000Hz) can be converted into a current signal (4-20mA).

  • Parameter Settings:
    • Input upper/lower limit: Amplitude range of input signal.
    • Output upper/lower limit: Amplitude range of output signal.
    • Overrun allowed: If checked, 1-5V converts to 4-20mA. If input is 0V, output follows to 0mA. If unchecked, output is 4mA and locked within range.
    • Automatic operation: If checked, signal conversion starts automatically on next power-on and stops when exited.
  • Instructions: When FN is red, press CONVERT to start/exit signal conversion. Backlights of up/down/left/right keys turn off.

6.4. Program Output

Automatically performs N cycles of signal output based on set parameters, useful for aging tests of electric/pneumatic valves or PLC program debugging.

  • Parameter Settings:
    • Mode: Single rise, single fall, or cycle.
    • Number of loops: 0 for infinite, max 30000.
    • Start value, End value, Increment step value, Increment step time, End stop (delay), Decrement step value, Decrease step time, Loop stop (delay).
  • Instructions: When FN is red, press AUTO to start/exit programming output. Backlights of up/down/left/right keys turn blue. Functions change to single run (up), program reset (down), single-step run (left), Stop/Continue (right).

6.5. Real-time Curve

Displays input and output signal trends graphically. Sampling time is adjustable, and the curve automatically scales within max/min values.

FNIRSI SG-004A display showing real-time curve view

Image: Real-time curve display on the SG-004A, showing input and output signal trends. Up to 100,000 or 15 sets of data can be recorded.

Detailed real-time curve record view with history

Image: Detailed view of the real-time curve record, including history view and curve display.

  • Instructions: When FN is red, press CURVE to switch the interface with/without curve.
  • Parameters: Output curve (red line), automatic output scaling, input automatic scaling, acquisition time (refresh interval).

6.6. History Record

  • Enable/Close Recording: When FN is red, press ON/OFF. The record number flashes on the screen.
  • View Record: Select a record in the setting interface history record, then ON/OFF to enter. Backlights of up/down/left/right keys turn yellow. Up/down views 100 record values, left/right views 1 record value.
  • Delete Record: While viewing a record, press ON/OFF.

6.7. Output Time

  • Output Activation Output Time: When checked, output automatically turns off after the set time expires.
  • Output Time: Set the desired output duration.

6.8. Communication

  • USB Connection: Uses USB analog serial port for communication. Note that charging will be slower when USB connection is active.
  • Modbus Slave: The SG-004A can communicate with configuration software or PLC via RS485. Refer to the attached tables (not included in this manual, but available in the full PDF) for register addresses and descriptions.

7. Wiring Instructions

Proper wiring is crucial for accurate measurements and safe operation. Refer to the diagrams below for common connection scenarios.

Wiring diagrams for FNIRSI SG-004A with PLC/Process instruments and pneumatic valves

Image: Wiring diagrams illustrating connections for PLC/Process instruments (all-round signal output) and pneumatic valves (valve position given/feedback). The diagrams show how to connect the SG-004A's IN, OUT, COM, and 24V ports for various signal types.

7.1. Connecting to PLC/Process Instrument

For all-round signal output (Current/Voltage/Millivolt/Frequency/Resistance/Thermal Resistance/Various Thermocouple Signals), connect the SG-004A as shown in the top two diagrams of the image. The connections are switched by electronic switches.

7.2. Connecting to Pneumatic Valves

For valve position control and feedback, refer to the bottom two diagrams in the image:

  • Valve Position Given/Feedback (Power Supply from SG-004A): Switch the IN(-) port to 24V to act as the power supply for valve feedback. Input and output are performed simultaneously.
  • Valve Position Given/Feedback (IN(-) as Negative Pole): The IN(-) port is closed to 24V and acts as the negative pole of the input signal. Input and output are performed simultaneously.

8. Troubleshooting

8.1. Fault Resolution

  • No response when SG-004A is turned on:
    • Check if the battery has power and if the charging indicator light is normal when charging.
    • A firmware upgrade error operation might lead to a system crash.
  • Abnormal screen display: Check if the screen is connected properly.
  • Abnormal output value or measured value:
    • Check the signal line connections.
    • Verify the interface for signal selection.
    • Ensure the target parameter of the connection does not exceed the technical indicator range, as this can cause abnormal operation or damage.
  • Error in input and output: Some errors are normal as input and output are not isolated.

8.2. Equipment Maintenance

  • The meter is powered by a 3.7V rechargeable lithium battery. Use the power adapter to extend battery life during long periods of use.
  • This instrument is not waterproof; avoid using it in high humidity environments.
  • Do not place the unit in unstable locations, or where it may be subject to strong vibrations.
  • Avoid high humidity, dust, direct sunlight, outdoor exposure, or high temperatures.

8.3. Firmware Upgrade

The SG-004A supports firmware upgrades via a USB emulated U disk.

  1. Plug the meter into a PC and turn it on. Wait for the PC to recognize the USB drive named "Bootloader".
  2. Copy the new firmware file to the "Bootloader" U disk.
  3. After a few seconds, the device will power on normally, and the upgrade will be successful.

Important Notes for Firmware Upgrade:

  • If the U disk is not recognized normally when connected to the PC, shut down and restart the device.
  • USB firmware upgrade only supports Windows 10. Do not drag or drop files other than those officially released by FNIRSI, as this may cause irreversible damage.

9. Specifications

The following tables detail the technical parameters and capabilities of the FNIRSI SG-004A Multi-functional Signal Generator.

Technical parameter table for FNIRSI SG-004A

Image: Comprehensive table of technical parameters including signal scope, precision, resolution, internal impedance, output signals, input signals, and extended functions.

9.1. General Specifications

PropertyValue
Model NumberSG-004A
Brand NameFNIRSI
DIY SuppliesElectrical
OriginMainland China
CertificationCE
Display Size2.4 Inches & Under
Battery IncludedYes
InterfaceType-C
Input5-12V/10W(Max)
Battery Capacity3000mAh
Standby Time24h
Dimensions (L*W*H)112mm * 77mm * 21mm (approx.)
Net Weight66g (approx.)
FNIRSI SG-004A dimensions and basic properties

Image: Basic properties, power properties, and packing list for the SG-004A, including dimensions.

FNIRSI SG-004A dimensions

Image: Detailed dimensions of the SG-004A: 82mm (3.23in) width, 28mm (1.10in) thickness, 112mm (4.41in) height, and 166g (0.37 pounds) weight.

9.2. Signal Output/Input Ranges & Precision

Signal TypeRangePrecisionResolutionImpedance
Current (mA)0-24mA± (0.02%+0.003)0.001mA100Ω
Voltage (V)0-24V±(0.02%+0.003)0.001V500K
Passive (XMT)0-24mA± (0.02%+0.003)0.001mA100Ω
24V loop0-24mA± (0.1%+0.005)0.01mA100Ω
FRQ (Hz)0-9999Hz±2%5 digits1MK
Millivolt (mV)-10~100mV±(0.03%+0.03)0.01mV2K
TC (TC-S)0-1760°C±(0.2%+1)1°C2K
TC (TC-B)0-1810°C±(0.5%+1)1°C2K
TC (TC-E)0-990°C±(0.2%+1)1°C2K
TC (TC-K)0-1320°C±(0.2%+1)1°C2K
TC (TC-R)0-1760°C±(0.3%+1)1°C2K
TC (TC-J)0-1190°C±(0.3%+1)1°C2K
TC (TC-T)0-390°C±(0.2%+1)1°C2K
TC (TC-N)0-1290°C±(0.2%+1)1°C2K
TC (WRe3/25)0-2320°C±(0.2%+1)1°C2K
TC (WRe5/26)0-2320°C±(0.2%+1)1°C2K
RES(ohm)0-390Ω±(0.2%+1)0.1Ω/
Pt100-200~650°C±(0.5%+1)0.1°C/
Cu50-20~150°C±(0.5%+1)0.1°C/
High precision testing results for mA and Voltage

Image: High precision testing results for mA input/output and Voltage input/output, demonstrating accuracy.

High precision testing results for Resistive, Millivolt, Rotating-speed, and Programming

Image: High precision testing results for Resistive Output, Millivolt Output, Rotating-speed Test, and Programming Test.

10. User Tips

  • Versatile Calibration: The SG-004A is highly versatile and can be used to calibrate various sensors and transmitters, including Pt100 RTDs and thermocouples. Ensure you select the correct signal type and parameters for accurate calibration.
  • Understanding Signal Types: Take time to familiarize yourself with the different signal types (mA, V, Hz, mV, Ohm, TC, RTD) and their specific settings to fully leverage the device's capabilities for your application.
  • Firmware Updates: Regularly check the manufacturer's website for new firmware versions to ensure your device has the latest features and bug fixes. Always follow the upgrade instructions carefully.

11. Warranty & Support

FNIRSI products undergo strict quality inspection. If you have any questions or need help, please contact FNIRSI customer service or the manufacturer directly.

A digital version of this user manual (PDF) is available for download. You can find it and any available firmware updates by scanning the QR code on the last page of the original manual or visiting the manufacturer's website. The PDF manual can be accessed at: FNIRSI SG-004A User Manual (PDF)

Manufacturer: Shenzhen FNIRSI Technology Co., Ltd.

Website: www.fnirsi.cn

Address: Building C, Weihuada Industrial Park, Dalang Street, Longhua District, Shenzhen, Guangdong, China

12. Production Information

Product Name: Multi-functional Signal Generator

Brand / Model: FNIRSI / SG-004A

Manufacturer: Shenzhen FNIRSI Technology Co., Ltd.

Website: www.fnirsi.cn

Address: Building C, Weihuada Industrial Park, Dalang Street, Longhua District, Shenzhen, Guangdong, China


FNIRSI SG-004A Signal Generator & Calibrator: Comprehensive Guide to Output & Input Functions

FNIRSI SG-004A Signal Generator & Calibrator: Comprehensive Guide to Output & Input Functions

1:00 • 1280×720 • guide
FNIRSI SG-004A Multi-functional Signal Generator: Unboxing, Features & Specifications Overview

FNIRSI SG-004A Multi-functional Signal Generator: Unboxing, Features & Specifications Overview

0:44 • 1280×720 • visual_overview
FNIRSI SG-004A Multifunction Process Calibrator: Signal Output & Input Demonstration

FNIRSI SG-004A Multifunction Process Calibrator: Signal Output & Input Demonstration

1:00 • 1280×720 • feature_demo
FNIRSI SG-004A Multifunction Signal Generator Unboxing & Features Overview

FNIRSI SG-004A Multifunction Signal Generator Unboxing & Features Overview

0:44 • 1280×720 • unboxing

Related Documents - SG-004A

Preview FNIRSI SG-003A Signal Generator User Manual
Comprehensive user manual for the FNIRSI SG-003A Signal Generator, detailing specifications, operation, functions like current, voltage, pulse signal generation, 24V loop detection, Modbus communication, troubleshooting, and firmware updates. Optimize industrial and professional applications.
Preview FNIRSI SG-003A Multi-function Signal Generator User Manual
The FNIRSI SG-003A is a versatile multi-function signal generator and process calibrator designed for industrial applications. It supports active and passive current, voltage, frequency, and pulse signal generation and measurement, offering features like engineering unit conversion, preset values, programmed output, real-time curve display, and Modbus communication. This user manual provides comprehensive instructions for operation, specifications, troubleshooting, and maintenance of the SG-003A.
Preview FNIRSI SG-004A Multi-functional Signal Generator Operating Manual
Comprehensive operating manual for the FNIRSI SG-004A multi-functional signal generator, detailing its specifications, functions, interface, operation, wiring, troubleshooting, and production information.
Preview FNIRSI SG-003A Signal Generator User Manual - 0-24V / 4-20mA Output
Comprehensive user manual for the FNIRSI SG-003A signal generator, covering safety instructions, product specifications, functions (signal conversion, programmed output, real-time curve), port descriptions, operation of buttons and display, troubleshooting, maintenance, firmware updates, and Modbus communication. Ideal for industrial and engineering applications requiring precise current and voltage signal generation.
Preview FNIRSI SG-004A Multi-functional Signal Generator Operating Manual
This operating manual provides comprehensive instructions for the FNIRSI SG-004A Multi-functional Signal Generator, covering its specifications, functions, button operations, signal descriptions, extensions, wiring, troubleshooting, and production information.
Preview FNIRSI SG-003A Signal Generator Product Manual
The FNIRSI SG-003A is a versatile signal generator product manual providing detailed instructions for its operation, including active and passive current output, voltage output, PWM generation, and various interface settings. It covers product parameters, wiring diagrams, manual and automatic interface operations, VC conversion, system settings, and important usage notes.