Bykski GZMN120-240-360-480N

Contents

Bykski Granzon GZMN Series Integrated Pump-Radiator Assembly

User Manual - EU Market Compliance Version

1. Product Overview

The Granzon GZMN Series Integrated Pump-Radiator Assembly is an all-in-one thin-type liquid cooling radiator with an integrated pump structure. It is designed to provide efficient cooling for PC components, particularly graphics card GPUs and VRAM, improving overall thermal performance for overclocked PC setups and simplifying internal chassis pipeline layout.

This assembly supports matching Granzon / GFM digital display pumps and Bykski full-coverage GPU water blocks.

Model Options

This integrated pump + radiator assembly is available in 4 specifications for 120mm fan installation:

  • GZMN120N: Single 120mm radiator
  • GZMN240N: Dual 120mm radiator
  • GZMN360N: Triple 120mm radiator
  • GZMN480N: Quad 120mm radiator
Granzon GZMN Series Integrated Pump-Radiator Assembly, showing 120mm, 240mm, 360mm, and 480mm models.
Granzon GZMN Series Integrated Pump-Radiator Assembly, showing 120mm, 240mm, 360mm, and 480mm models.
Granzon GZMN radiator in an expansion mode setup with a GPU water block.
Granzon GZMN radiator in an expansion mode setup with a GPU water block.

Product Showcase Video

A short video showcasing the unboxing and physical appearance of the Granzon GZMN240N radiator.

2. Specifications

Key Features

  • Unified pump-radiator integrated design, saves chassis installation space.
  • Thin radiator structure compatible with standard 120mm cooling fans.
  • Modular expandable structure, easy to assemble with dedicated water cooling fittings.
  • Optimized internal flow channel design, low flow resistance to reduce pump humming resonance noise.
  • Sealed precision brazed radiator core for long-term leak-proof stability.

General Product Properties

Property Value
Brand Namebykski
Model NumberGZMN120-240-360-480N
TypeRadiator & Pump
Radiator MaterialCopper Brass
ColorBlack
RGB SupportNO RGB
Compression Fittings Includedno
OriginMainland China
CertificationNONE

Integrated Pump Parameters (Model: B-PMD3-X)

Parameter Value
ModelB-PMD3-X
ColorBlack
MaterialABS resin + PMMA
Driving modeSINE WAVE
Driving technologySuper durable PCB, solid state capacitance and patch sensor
Load speedMax 5000rpm
Power wasteDC12V, TDP15W
Voltage range10V-15V
Maximum flow rate600L/H
Working temperature4000rpm speed at 38°C
Type of pump coverCompatible ODC pump cover
Output range6 meters
Signal interfaceLarge 4PIN+PWM+data feedback
Product size62 X 62 X 52.5 (MM)

Dimensions

Detailed dimensions diagram for GZMN 120N, 240N, 360N, and 480N radiators.
Detailed dimensions diagram for GZMN 120N, 240N, 360N, and 480N radiators.

3. Safety Information

⚠ Read all safety instructions fully before installation, wiring, filling coolant and maintenance work. Improper operation may lead to coolant leakage, computer hardware short-circuit damage, component burnout, personal scald injury, and void your product warranty.

  • This product is exclusively designed for custom PC liquid cooling systems for CPU / GPU heat dissipation. Do not use it for industrial fluid transportation, drinking water circulation, hydraulic equipment or any other non-design application scenarios.
  • Cut off the entire host power supply and unplug all power cables before disassembly, pipe modification, draining or refilling coolant, to prevent short-circuit accidents caused by spilled cooling liquid contacting circuit boards.
  • When installing G1/4 threaded fittings on inlet/outlet ports, wrap appropriate PTFE thread tape and tighten with moderate torque. Excessive tightening will crack thread bases and radiator end caps; insufficient tightening causes thread seepage.
  • Never run the integrated pump without coolant inside the loop (dry running). Dry operation will rapidly wear internal pump shaft structures, cause overheating, permanent pump failure and seal damage.
  • Only use dedicated ethylene glycol / propylene glycol PC cooling fluid. Tap water, acidic, alkaline or corrosive chemical solutions will corrode radiator internal micro channels, cause scaling, blockage and long-term leakage risk.
  • Do not arbitrarily drill, cut, bend, strike or deform the radiator body or pump housing; structural damage will lead to cracking and liquid leakage under system working pressure.
  • Small fasteners, gaskets and accessories shall be kept away from children to avoid choking hazard from accidental ingestion.
  • Immediately cut off power and stop operation if abnormal loud noise, persistent liquid seepage, bulging or deformation is found during running; drain all coolant and perform full inspection before reuse.

Product Usage Restrictions & Operating Limits

  • Maximum Working Pressure: Sustained internal system pressure ≤ 1.5 bar. Excessive pressure will damage sealing structure and trigger coolant leakage.
  • Temperature Operating Range: Ambient working temperature: 5°C ~ 55°C, relative humidity below 90% RH; Allowable coolant working temperature: 0°C ~ 70°C. Do not install in severely dusty, high-humidity condensation-prone, corrosive gas environments.
  • Flow & Noise Restriction: Avoid excessive total loop resistance from excessive elbows, extension adapters and restrictors. High loop backpressure will aggravate pump load and generate obvious low-frequency humming resonance noise.
  • Fan Installation Limit: Only install standard 120mm specification cooling fans. Do not use oversized or mismatched fans that cause extrusion stress on radiator surface.
  • Mounting Angle Restriction: Avoid installing the radiator upside-down as the highest point of the cooling loop; trapped air will accumulate inside radiator channels, resulting in persistent humming noise and uneven heat dissipation.
  • Vibration Isolation Requirement: Use shock-absorbing screws or vibration pads during radiator fixed installation; rigid direct contact with chassis metal panels will transmit pump vibration and amplify system buzzing noise.

4. Installation Guide

Step-by-Step Installation & Operation Guide

  1. Pre-Installation Inspection

    • Confirm selected model (GZMN120N / GZMN240N / GZMN360N / GZMN480N) matches chassis internal installation space.
    • Inspect radiator fins, pump assembly, end caps and threaded ports for dents, cracks, scratches or factory leakage defects.
    • Prepare matching pump unit (Granzon/GFM digital display pump), GPU water block (Bykski series), G1/4 fittings, PTFE thread tape, cooling fluid, mounting screws and 120mm fans.
  2. Fan Mounting

    • Align 120mm cooling fan with radiator mounting holes, install anti-vibration screws evenly to fasten fan onto radiator surface.
    • Confirm fan airflow direction: air flows through radiator fins to realize forced convection heat dissipation.
  3. Pump Assembly Connection

    • Install dedicated sealing gaskets between pump body and radiator integrated base interface.
    • Fasten fixing screws in diagonal sequence with uniform torque to ensure complete sealing between pump and radiator joint, no assembly gaps.
    • Complete pump wiring according to pump specification: connect 12V power supply and PWM speed regulation signal cable to motherboard fan header or power supply connector strictly following pin definition, avoid reversed power polarity burning pump circuit.
  4. Pipeline & Water Block Assembly

    • Wind PTFE thread tape clockwise on external threads of inlet/outlet tube fittings, screw fittings moderately into radiator G1/4 ports, avoid over-tightening cracking end caps.
    • Connect tubing between radiator loop and Bykski GPU water block, reserve proper pipe slack to prevent tension pulling joints loose, prevent pipes squeezing or vibrating against chassis metal plates.
  5. Loop Filling & Full Air Exhaust

    • Assemble complete closed cooling loop, slowly inject dedicated cooling liquid into filling port, do not fully fill the loop; reserve thermal expansion space for liquid volume change.
    • Tilt chassis repeatedly back and forth to exhaust trapped air inside radiator internal channels, pump cavity and entire pipeline. Trapped air is the primary root cause of continuous humming noise during system operation.
  6. Mandatory Offline Leak Test

    • Run the pump offline (motherboard, graphics card unpowered) for no less than 30 consecutive minutes.
    • Repeatedly inspect radiator end caps, pump-radiator joint, all threaded fittings and tube connections for liquid seepage, dripping or condensation traces.
    • If bubbling or obvious abnormal humming occurs, repeat venting operation to eliminate residual air inside the cooling system.
  7. Formal Installation & Power-On Verification

    • After leak test passes with zero seepage, mount the whole pump-radiator assembly to chassis reserved mounting position, arrange tubing neatly.
    • Start computer and cooling system, adjust pump & fan speed curve in BIOS or fan control software, monitor radiator temperature, sealing status and abnormal noise under idle and GPU high-load operation.

5. Operating Instructions

Once the system is fully installed and leak-tested, you can power on your PC. Monitor the cooling system's performance and adjust pump and fan speeds as needed through your motherboard's BIOS or dedicated fan control software. Ensure the radiator temperature, sealing status, and noise levels remain within acceptable limits during both idle and high-load operations.

Always ensure the pump is running with coolant in the loop to prevent damage from dry running.

6. Maintenance

Regular Maintenance Instructions

  • Perform visual inspection every 3 months: Check joint tightness, leakage signs, pipe aging, fan dust accumulation and vibration condition.
  • Complete loop draining, internal flushing and coolant replacement every 12-18 months, prevent scaling, microbial growth and channel blockage.
  • Cut off all power supply and drain residual coolant before disassembly maintenance, prevent liquid splashing damaging motherboard and electronic components.
  • Store spare radiator assembly in cool, dry indoor environment, avoid long-term exposure to strong ultraviolet light, high temperature and humid corrosive atmosphere.

Maintenance Cycle Limit

Fully drain, flush the entire loop and replace cooling fluid every 12~18 months, to prevent impurity deposition, algae growth, internal channel clogging and gradual noise rise.

7. Troubleshooting

Common Troubleshooting Scenarios

  • Continuous low-frequency humming noise after startup:
    • Cause: Trapped air accumulated inside radiator channels / pump cavity.
    • Solution: Refill cooling fluid, fully exhaust system residual air by tilting chassis, adjust liquid level to standard range.
  • Noise becomes louder when pump speed increases:
    • Cause: Excessive overall loop resistance from redundant elbows/extension fittings.
    • Solution: Optimize pipeline layout, remove unnecessary fittings to reduce flow resistance.
  • Liquid seepage at threaded ports or pump-radiator joint:
    • Cause: Insufficient PTFE tape, uneven tightening torque, misplaced/deformed sealing gasket.
    • Solution: Disassemble joint, clean thread residues, re-seat gasket, re-wrap thread tape and reassemble with moderate torque.
  • Uneven heat dissipation, high GPU temperature:
    • Cause: Air blockage inside radiator, insufficient pump flow, poor contact between water block and GPU.
    • Solution: Re-exhaust trapped air, check pump running status, re-install GPU water block with standard compression torque.
  • Radiator fin deformation / slow heat dissipation after long-term use:
    • Cause: Dust accumulation blocking airflow, long-term foreign object extrusion.
    • Solution: Regularly blow clean radiator fins with low-pressure compressed air, avoid external extrusion stress.
  • Gradually increasing running noise after long service time:
    • Cause: Aging coolant, internal impurity deposition blocking micro channels.
    • Solution: Drain old coolant, flush radiator and whole loop thoroughly, replace with new dedicated cooling liquid.

8. User Tips

No specific user tips were available from reviews or Q&A content for this product at this time. Always refer to the detailed installation and maintenance instructions provided in this manual for optimal performance and longevity of your cooling system.

9. Warranty and Support

For warranty information, technical support, or any product-related inquiries, please contact the seller or manufacturer directly. Ensure you retain your proof of purchase for warranty claims.

A PDF version of the user manual is available for download: View User Manual (PDF)

© 2023 Bykski. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.