Gaqqee W3001 W3002

Rate this product if you’ve used it
Contents

Gaqqee W3001/W3002 Digital Temperature Controller User Manual

Models: W3001, W3002

Brand: Gaqqee

1. Introduction

The Gaqqee W3001 and W3002 are versatile digital temperature controllers designed for a wide range of temperature control applications. These microcomputer-controlled thermostats offer automatic mode operation, a broad temperature control range, and high accuracy. Featuring a high-brightness digital display, they ensure clear readability day or night. The robust ABS material shell provides mechanical strength, good electrical performance, and anti-aging properties. The sensor is easily replaceable using a 2P terminal, allowing for flexibility with different probes. With a wiring input and output design, these controllers are convenient for integration into various industrial and domestic control equipment, ensuring safe and reliable operation.

Gaqqee W3001 and W3002 Digital Temperature Controllers side-by-side
Gaqqee W3001 and W3002 Digital Temperature Controllers

2. Safety Information

  • Ensure all wiring is performed by a qualified professional to prevent electrical hazards.
  • Verify the power supply voltage matches the controller's specifications (12V, 24V, or 220V).
  • Do not power on the W3001 model if the output is not connected to a load, as this can lead to two-level contact of the wire and ignition.
  • Keep the device away from water and high humidity environments unless the probe is specifically designed for such conditions.
  • Do not attempt to disassemble or modify the device, as this may void the warranty and pose safety risks.
  • Always disconnect power before performing any installation, wiring, or maintenance.

3. Product Overview

The W3001 and W3002 temperature controllers feature a clear LED digital display and intuitive button controls for easy setup and monitoring.

3.1. Components

W3002 Temperature Controller Panel Layout
W3002 Panel Layout: Output indicator, Detection temperature, Up button, Down button, Settings button, Product number.
W3001 Temperature Controller Panel Layout
W3001 Panel Layout: Output indicator, Detection temperature, Up button, Down button, Settings button, Product number.
  • Output Indicator: Lights up when the output is active.
  • Detection Temperature Display: Shows the current temperature measured by the sensor.
  • Up Button: Used to increase values or navigate menus.
  • Down Button: Used to decrease values or navigate menus.
  • Settings Button: Used to enter and confirm settings.
  • Product Number: Model identification (e.g., XH-W3001, XH-W3002).

4. Specifications

4.1. XH-W3001

FeatureSpecification
Supply Voltage12V / 24V / 220V (model dependent)
Temperature Measurement Range-50℃ to 110℃
Temperature Control Range-50℃ to 110℃
Temperature Control Accuracy0.1℃
Load Power120W (12V), 240W (24V), 1500W (220V)
Measurement InputNTC10K waterproof probe L=1 meter
Output TypeDirect Output
Output CapacityMax 10A
Installation Hole Distance73mm (aperture 4mm)
Appearance Size60mm x 45mm x 31mm

4.2. XH-W3002

FeatureSpecification
Supply Voltage12V / 24V / 220V (model dependent)
Temperature Measurement Range-50℃ to 110℃
Temperature Control Range-50℃ to 110℃
Temperature Measurement Accuracy±0.2℃
Temperature Control Accuracy±0.1℃
Measurement InputNTC10K L=1 meter waterproof probe
Output TypeDirect Output
Output CapacityMax 10A
Installation Hole Distance73mm (aperture 4mm)
Appearance Size60mm x 45mm x 31mm

5. Installation

The W3001 and W3002 models are designed for easy installation and fixation, featuring side holes on both sides of their 1.8mm thick ABS material shell.

5.1. Installation Dimensions

W3001 Installation Dimension Diagram
W3001 Installation Dimension Diagram (Hole spacing 73mm, Aperture M4(4mm), Corner radius 3mm)
W3002 Installation Dimension Diagram
W3002 Installation Dimension Diagram (Hole spacing 73mm, Aperture M4(4mm), Corner radius 3mm)

6. Wiring Diagram

Proper wiring is crucial for the safe and correct operation of the temperature controller. Refer to the diagrams below for your specific model and voltage.

6.1. W3001 Wiring

W3001 12V/24V DC Wiring Diagram
W3001 12V/24V DC Wiring Method: Connect to a 12V/24V DC power supply. The output is direct to the load (e.g., light bulb). Note: W3001 is a direct output. Do not power on if the output is not connected to a load to prevent short circuits.
W3001 220V AC Wiring Diagram
W3001 220V AC Wiring Method: Connect to a 220V AC power supply. The output is direct to the load (e.g., light bulb).

6.2. W3002 Wiring

W3002 12V/24V DC Wiring Diagram
W3002 12V/24V DC Wiring Method: Connect to a 12V/24V DC power supply. The output is direct to the load (e.g., light bulb).
W3002 220V AC Wiring Diagram
W3002 220V AC Wiring Method: Connect to a 220V AC power supply. The output is direct to the load (e.g., light bulb).

7. Operating Instructions

This section details how to set up and operate your Gaqqee temperature controller.

7.1. XH-W3001 Instructions

  1. Set Startup Temperature:
    Press the Up button once to display the current startup temperature. Long press the Up button for approximately 3 seconds until the startup temperature number flashes. Use the Up and Down buttons to set your desired startup temperature value.
  2. Set Stop Temperature:
    Press the Down button once to display the current stop temperature. Long press the Down button for approximately 3 seconds until the stop temperature number flashes. Use the Up and Down buttons to set your desired stop temperature value.
  3. Restore Factory Settings (Reset):
    When the device is powered on, simultaneously press and hold both the Up and Down buttons. The digital display will show "888" and then automatically return to the detection temperature, indicating that factory settings have been restored.

7.2. XH-W3002 Instructions

  1. P0 Set Startup Temperature:
    Press the Settings button once to enter the internal menu. The display will show "P0". Press the Settings button again. Use the Up and Down buttons to set the required startup temperature.
  2. P1 Set Stop Temperature:
    Press the Settings button once to enter the internal menu. Use the Up or Down buttons to navigate to "P1". Press the Settings button again. Use the Up and Down buttons to set the desired stop temperature.
  3. P2 Set Temperature Correction:
    Enter the internal menu (press Settings once). Use the Up or Down buttons to navigate to "P2". Press the Settings button again. Use the Up and Down buttons to set the required calibration temperature.
    • If the detected temperature is 0.5°C higher than actual, set correction to -0.5°C.
    • If the detected temperature is 1°C lower than actual, set correction to 1°C.
    • Formula: Detected Temperature ± Corrected Temperature = Actual Temperature.
  4. P3 Set Delay Start:
    Enter the internal menu (press Settings once). Use the Up or Down buttons to navigate to "P3". Press the Settings button again. Use the Up and Down buttons to set the required delay time in minutes. This function is typically used for compressor refrigeration (e.g., refrigerators, freezers) to prevent rapid cycling. A common setting is 3-6 minutes, depending on the compressor's back pressure. If not controlling a compressor or if a delay is not needed, this setting can be skipped.

7.3. Operation Demonstration Video

Video demonstrating the temperature control functionality, including setting the stop temperature and observing the fan's response to temperature changes.

8. User Tips

  • Always double-check your wiring connections before applying power to avoid damage to the unit or connected devices.
  • For applications requiring precise temperature control, utilize the temperature correction (P2) feature to fine-tune readings.
  • When using the delay start (P3) function for compressors, ensure the delay time is appropriate for your equipment to prevent wear and tear.
  • The 2P terminal allows for easy replacement of the NTC sensor. If you need a different probe type or length, ensure it is compatible with NTC10K specifications.

9. Troubleshooting

  • Display Not Working: Check power connections and ensure the correct voltage is supplied. Verify the wiring is secure and free from damage.
  • Temperature Not Controlling: Ensure the startup and stop temperatures are set correctly. Check the sensor connection and ensure it is properly immersed in the medium being measured. Verify the load is correctly wired and functional.
  • Incorrect Temperature Reading: Perform a temperature correction (P2 setting for W3002, or compare with a known accurate thermometer for W3001) if the reading appears inaccurate. Ensure the sensor is not damaged or improperly installed.
  • Output Not Activating: Check if the current temperature is within the set range to trigger the output. Ensure the load connected to the output is not faulty.

10. Maintenance

  • Cleaning: Gently wipe the device's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sensor Care: Ensure the NTC waterproof probe is clean and free from debris. Avoid bending or damaging the probe cable.
  • Connection Check: Periodically inspect all wiring connections to ensure they remain tight and secure.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Retain your purchase receipt for proof of purchase.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?