User Manual: TKXEC h56ch Battery Monitor Hall Coulomb Tester

Model: h56ch

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your TKXEC h56ch Battery Monitor Hall Coulomb Tester. This device is designed to accurately measure and display battery voltage, current, capacity (AH), power (W), and charge/discharge time for various battery types. It is suitable for lithium batteries, lithium iron phosphate, lead-acid, nickel-metal hydride, and other battery packs with operating voltages of 9-100V.

H56C Coulombmeter display and Hall sensor with icons for Battery Power %, Battery capacity, Voltage, Current, Power, and Charge and discharge time.
The H56C Coulombmeter and its Hall sensor, illustrating the various parameters it measures.

2. Specifications

2.1. Technical Parameters

ParameterValue
Voltage Measurement Range9-100V DC
Current Range (Optional)0-100A / 0-200A / 0-300A / 0-500A
Test Capacity Range0-99.9KAH
Test Power Range0-999999W
Time Record0:00:00 - 999:59:59
Working Current (Backlight On)≈10mA
Working Current (Backlight Off)≈5mA
Product Accuracy0.5%
Voltage Resolution0.1V
Current Resolution0.1A
Voltage Display Mode0.0-99.9-100V
Capacity Display Mode0-999mAH-1.00AH-9.99AH-10.0AH-99.9AH-100AH-999AH-1.00KAH-9.99KAH-10.0KAH-99.9KAH
Power Display Mode0.0-99.9W-100W-999W-1.00KW-9.99KW-10.0KW-99.9KW-100KW-999KW

2.2. Dimensions and Weight

  • Product Dimensions: Approximately 79mm (length) x 43mm (width) x 39.5mm (height)
  • Mounting Hole Dimensions: Approximately 76.5mm x 27mm
  • Product Weight: Approximately 0.15 kg
H56C Coulombmeter with dimensions labeled: 79mm length, 43mm width, 39.5mm height, and 76.5mm x 27mm for mounting.
Physical dimensions of the H56C Coulombmeter.

3. Setup

3.1. Wiring Diagram

The following diagram illustrates the correct wiring for the H56C Coulombmeter. Ensure all connections are secure before operation.

Wiring diagram for the H56C Coulombmeter showing connections to battery, load, and charger. The Hall sensor is placed on the main current path.
Wiring diagram for DC 9-100V systems.

3.2. Initial Wiring and Current Check

  1. All wires from the positive (or negative) terminal of the battery must pass through the Hall sensor.
  2. The correct wiring ensures the coulomb counter displays a positive current when charging and a negative current when discharging. If this is not observed, reverse the orientation of the Hall sensor.
  3. If the current displayed is not zero when no load is connected, perform a current zero calibration (refer to section 5.2, parameter 09CZ).

4. Operation

4.1. Display Interface Overview

The main display shows various battery parameters and status indicators. The buttons allow for navigation and quick actions.

H56C Coulombmeter display interface showing Battery Graphics, Remaining Capacity, Capacity %, Voltage, Current, Power, and button functions for setting, zeroing capacity, and full capacity.
Main display interface and button functions.

This mode simplifies initial setup and is recommended for most users.

  1. Wiring and Current Check: Follow the steps in section 3.2.
  2. Battery Capacity Reset: After the first use or battery replacement, the displayed capacity may not be accurate. To calibrate:
    • Fully discharge the battery until it is empty.
    • Press and hold the down arrow button for 3 seconds. The capacity value and percentage will reset to 0%.
    • Begin charging the battery. The capacity will automatically display 100% when fully charged. This process is automatic and requires no further user intervention.
  3. Special Case - Manual Full Capacity: If the capacity does not display 100% after the charger indicates full charge, you can manually set it to 100% by long-pressing the up arrow button (ensure the charger remains connected).

4.3. Manual Mode

This mode is for users who have a detailed understanding of their battery's characteristics.

  1. Wiring and Current Check: Follow the steps in section 3.2.
  2. Setting Parameters: The following two parameters must be set:
    • Battery Rated Capacity (11CA): Set the effective capacity of your battery in the menu item 11CA.
    • Full-Charge Automatic Full-Capacity Voltage (12FV): Set this voltage in menu item 12FV. It is recommended to set this to the highest voltage displayed by the coulomb counter when the battery is fully charged and the charger is still connected.
  3. Initial Full Charge: After connecting wires and setting parameters, the display will not immediately show battery capacity. The battery icon and capacity will be empty. The battery needs to be fully charged once to display the remaining power normally.

4.4. Button Definitions (Normal Measurement Interface)

  • Setting Key (Gear Icon):
    • Long press (3 seconds): Enter the setting menu.
    • Short press (1 second): Toggle backlight display on/off.
  • Down Arrow Key:
    • Long press (3 seconds): Set capacity to zero.
    • Short press (1 second): View project mode (for manufacturer use, can be skipped).
  • Up Arrow Key:
    • Long press (3 seconds): Set to full capacity (for special cases, e.g., manual full charge).
    • Short press (1 second): Release alarm.

5. Parameter Settings

To access the parameter settings, long-press the Setting Key (Gear Icon) from the normal measurement interface.

H56C Coulombmeter parameter setting menu showing options like Zero capacity voltage, Overvoltage alarm, Overcurrent alarm, Low voltage alarm, and button controls for modifying and saving settings.
Parameter setting interface and button functions.

5.1. Menu Parameters

Menu ItemAdjustment RangeDefault ValueComment
01ZV (Zero-capacity voltage)0.0-100V0.0VIf the voltage drops below this value, capacity is automatically set to 0%. Do not set if battery discharge voltage characteristics are unknown.
02OV (Overvoltage alarm)0.0-100V100VIf voltage exceeds this, the voltage value flashes and the buzzer sounds intermittently.
03OC (Over-current alarm)0 - Max range valueMax range valueIf current exceeds this, the current value flashes and the buzzer sounds intermittently.
04LV (Low voltage alarm)0.0 - Overvoltage value0.0VIf voltage drops below this, the voltage value flashes and the buzzer sounds intermittently.
05LB (Low capacity alarm)0-100%0%If capacity drops below this, percentage and battery symbol flash, and the buzzer sounds intermittently.
06HT (High temperature alarm)-9 to 99℃99℃If temperature exceeds this, the temperature value flashes and the buzzer sounds intermittently. (Standard products may not have this function).
07VC (Voltage value fine-tuning)AdjustableN/AAdjust if the displayed voltage value has a deviation.
08CC (Current value fine-tuning)AdjustableN/AAdjust if the displayed current value has a deviation.
09CZ (Current zero calibration)N/AN/APerform if the current is not 0 at no-load.
10TC (Temperature value fine-tuning)AdjustableN/AAdjust if the displayed temperature value has a deviation. (Standard products may not have this function).
11CA (Battery effective capacity)Automatic/ManualN/AAutomatic test capacity, can be manually set under special circumstances.
12FV (Full capacity voltage)0V0VWhen voltage is higher than this, capacity is automatically set to 100%. This function only works in manual mode.
13LK (Menu lock)LOCK/UnLOCKLOCKOnly when unlocked (UnLOCK) can menu items 01-12 be modified.
14DF (Restore default value)NO/YESNOSelect YES to restore all current parameters to factory settings.

Note: Menu items 01-12 can only be modified when the menu lock (13LK) is set to UnLOCK.

5.2. Button Definitions (Menu Setting Interface)

  • Setting Key (Gear Icon):
    • Long press (3 seconds): Enter the item line to modify its value.
    • Short press (1 second): Save the parameters and return to the previous menu.
  • Down Arrow Key:
    • Short press (1 second): Select plus or minus digit when modifying a value.
  • Up Arrow Key:
    • Short press (1 second): Modify the setting value (increment/decrement).

6. Troubleshooting (FAQ)

Q1: Do I need to set parameters when using the coulomb counter?
A1: No, for the first use, simply connect it correctly, fully discharge the battery, then charge it completely. The device will automatically calibrate. Manual settings are only needed for special cases or specific battery characteristics.
Q2: Does the coulomb counter need an external switch?
A2: No, the backlight automatically turns off when there is no current, reducing power consumption to approximately 5mA, which is negligible.
Q3: Does the Hall sensor have a specific direction?
A3: Yes. The coulomb counter should display positive current during charging and negative during discharging. If this is reversed, simply flip the Hall sensor's orientation.
Q4: During discharge, power decreases, but why doesn't it increase during charging?
A4: Ensure the Hall sensor is connected to the total positive or total negative pole, and that ALL charging and discharging circuits pass through the Hall sensor for accurate measurement.
Q5: Why does the coulomb counter show a small current (e.g., a few tenths of an ampere) when the battery is not charging or discharging?
A5: This can be due to device aging or ambient temperature. Perform a current zero calibration (parameter 09CZ) when there is no load.
Q6: My battery has been used for a long time, and I don't know its real AH capacity. What should I do?
A6: Fully discharge the battery until it's empty. Then, press and hold the down arrow button for 3 seconds to reset the capacity to 0%. Now, fully charge the battery. The device will automatically learn and display the capacity. If it doesn't show 100% after full charge, long-press the up arrow button (with charger still connected) to manually set it to 100%.
Q7: Can the battery capacity be set manually?
A7: Yes. First, set the effective capacity of the battery in menu item 11CA. Then, fully charge the battery and long-press the up arrow button (with charger still connected) to manually set it to 100%.

7. User Tips

  • For initial setup or after battery replacement, fully discharge the battery, then long-press the 'down arrow' button for 3 seconds to reset capacity to 0%. Then fully charge the battery for automatic calibration.
  • If the current is not zero at no-load, perform a zero calibration using the 09CZ setting in the parameter menu.
  • Ensure the Hall sensor is correctly positioned on the main current path (either positive or negative) so that all charging and discharging current flows through it for accurate readings.
  • When manually setting full capacity (long-pressing the up arrow), ensure the charger is still connected to the battery.

8. Maintenance

  • Keep the device clean and dry. Avoid exposure to moisture or extreme temperatures.
  • Do not use harsh chemicals or abrasive cleaners. Wipe with a soft, damp cloth if necessary.
  • Ensure all wiring connections remain tight and free from corrosion.
  • Store the device in a safe place when not in use to prevent physical damage.

9. Warranty and Support

For any technical issues, questions, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records for reference. Specific warranty terms may vary by region and seller.